{"id":"https://openalex.org/W2157443822","doi":null,"title":"Voltage collapse in electric power system","display_name":"Voltage collapse in electric power system","alternate_titles":[],"publication_year":1991,"publication_date":"1991-11-05","ids":{"openalex":"https://openalex.org/W2157443822","mag":"2157443822"},"language":"en","primary_location":{"id":"mag:2157443822","doi":null,"is_oa":false,"landing_page_url":"http://ieeexplore.ieee.org/iel3/1160/4020/00154047.pdf","pdf_url":null,"source":{"id":"https://openalex.org/S7407088561","display_name":"IET International Conference on Advances in Power System Control, Operation and Management (APSCOM)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"International Conference Advances Power System Control, Operation and Management","raw_type":null},"parent_works":[],"lineage":["https://openalex.org/W2157443822"],"child_works_count":0,"pull_notice_works":[],"type":"conference-paper","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5059643762","display_name":"Suresh Chandra Srivastava","type":null,"orcid":"https://orcid.org/0000-0002-7588-7094","observed_orcids":["https://orcid.org/0000-0002-7588-7094"]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I94234084","display_name":"Indian Institute of Technology Kanpur","ror":"https://ror.org/05pjsgx75","country_code":"IN","type":"education","lineage":["https://openalex.org/I94234084"]}],"countries":["IN"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"S.C. Srivastava","raw_affiliation_strings":["Dept. of Electr. Eng., Indian Inst. of Technol. Kanpur, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dept. of Electr. Eng., Indian Inst. of Technol. Kanpur, India","institution_ids":["https://openalex.org/I94234084"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5057869785","display_name":"Prem Kumar Kalra","type":null,"orcid":"https://orcid.org/0000-0002-8740-2461","observed_orcids":["https://orcid.org/0000-0002-8740-2461"]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I94234084","display_name":"Indian Institute of Technology Kanpur","ror":"https://ror.org/05pjsgx75","country_code":"IN","type":"education","lineage":["https://openalex.org/I94234084"]}],"countries":["IN"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Prem Kalra","raw_affiliation_strings":["Dept. of Electr. Eng., Indian Inst. of Technol. Kanpur, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dept. of Electr. Eng., Indian Inst. of Technol. Kanpur, India","institution_ids":["https://openalex.org/I94234084"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5046405021","display_name":"Ranjan Bose","type":null,"orcid":"https://orcid.org/0009-0007-9102-6327","observed_orcids":["https://orcid.org/0009-0007-9102-6327"]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I94234084","display_name":"Indian Institute of Technology Kanpur","ror":"https://ror.org/05pjsgx75","country_code":"IN","type":"education","lineage":["https://openalex.org/I94234084"]}],"countries":["IN"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Ranjan Bose","raw_affiliation_strings":["Dept. of Electr. Eng., Indian Inst. of Technol. Kanpur, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dept. of Electr. Eng., Indian Inst. of Technol. Kanpur, India","institution_ids":["https://openalex.org/I94234084"]}]},{"author_position":"last","author":{"id":null,"display_name":"Mayank Agarwal","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I94234084","display_name":"Indian Institute of Technology Kanpur","ror":"https://ror.org/05pjsgx75","country_code":"IN","type":"education","lineage":["https://openalex.org/I94234084"]}],"countries":["IN"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Mayank Agarwal","raw_affiliation_strings":["Dept. of Electr. Eng., Indian Inst. of Technol. Kanpur, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dept. of Electr. Eng., Indian Inst. of Technol. Kanpur, India","institution_ids":["https://openalex.org/I94234084"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I94234084"],"apc_list":null,"apc_paid":null,"fwci":1.475,"has_fulltext":false,"cited_by_count":2,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.72092504,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":92},"biblio":{"volume":null,"issue":null,"first_page":"69","last_page":"75"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9984999895095825,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9984999895095825,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.0003000000142492354,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.0003000000142492354,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/voltage-collapse","display_name":"voltage collapse","score":0.9990000128746033},{"id":"https://openalex.org/keywords/voltage-stability","display_name":"voltage stability","score":0.9959999918937683},{"id":"https://openalex.org/keywords/hvdc-transmission","display_name":"HVDC transmission","score":0.8980000019073486},{"id":"https://openalex.org/keywords/transformer-tap-settings","display_name":"transformer tap settings","score":0.9639999866485596},{"id":"https://openalex.org/keywords/short-circuit-ratio","display_name":"short-circuit ratio","score":0.8080000281333923},{"id":"https://openalex.org/keywords/load-effects","display_name":"load effects","score":0.4650000035762787},{"id":"https://openalex.org/keywords/transmission-line-parameters","display_name":"transmission line parameters","score":0.5640000104904175}],"concepts":[{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.7116808891296387},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.6120307445526123},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5935487747192383},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5886263847351074},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.539775550365448},{"id":"https://openalex.org/C113608303","wikidata":"https://www.wikidata.org/wiki/Q1056835","display_name":"Transmission system","level":3,"score":0.48613497614860535},{"id":"https://openalex.org/C196226539","wikidata":"https://www.wikidata.org/wiki/Q7940752","display_name":"Voltage regulation","level":3,"score":0.4525853097438812},{"id":"https://openalex.org/C2989126829","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Power network","level":4,"score":0.4387856721878052},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.38737207651138306},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.35072776675224304},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.3237118124961853},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.26673537492752075},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.2560969591140747},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2157443822","doi":null,"is_oa":false,"landing_page_url":"http://ieeexplore.ieee.org/iel3/1160/4020/00154047.pdf","pdf_url":null,"source":{"id":"https://openalex.org/S7407088561","display_name":"IET International Conference on Advances in Power System Control, Operation and Management (APSCOM)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"International Conference Advances Power System Control, Operation and Management","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.5690000057220459},{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.5378999710083008}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2727638506","https://openalex.org/W2103540530","https://openalex.org/W196915189","https://openalex.org/W1601821822","https://openalex.org/W2153446581","https://openalex.org/W1997788167","https://openalex.org/W2594526778","https://openalex.org/W296139669","https://openalex.org/W2373492005","https://openalex.org/W2133179573"],"abstract_inverted_index":{"Some":[0],"of":[1,8,67,85],"the":[2,5,14,28,31,42,65,69],"factors":[3],"affecting":[4],"voltage":[6,32,43],"stability":[7],"a":[9,51,58],"electric":[10],"power":[11],"system":[12,23,48],"are":[13],"loadings":[15],"and":[16,57,72,75,88],"transformer":[17,73],"tap":[18,74],"settings.":[19],"In":[20],"addition,":[21],"different":[22,81],"parameters":[24,76],"may":[25],"also":[26],"alter":[27],"proximity":[29],"to":[30],"collapse":[33,44],"point.":[34],"The":[35,61],"authors":[36,62],"present":[37],"certain":[38],"important":[39],"observations":[40],"on":[41,50],"phenomenon":[45],"established":[46],"through":[47],"studies":[49],"sample":[52],"EHV":[53,78],"AC":[54,79,91],"transmission":[55,70],"network":[56],"HVDC":[59,94],"network.":[60,95],"bring":[63],"out":[64],"effects":[66],"changing":[68],"line":[71],"in":[77,93],"network,":[80],"short":[82],"circuit":[83],"ratio":[84],"receiving":[86],"end":[87,90],"sending":[89],"systems":[92],">":[96]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2157443822","counts_by_year":[{"year":2019,"cited_by_count":1}],"updated_date":"2026-11-25T09:40:18.809321","created_date":"2016-06-24T00:00:00"}
