{"id":"https://openalex.org/W2155777988","doi":"https://doi.org/10.1109/tia.2013.2240643","title":"Thermal Analysis of Multilevel Grid-Side Converters for 10-MW Wind Turbines Under Low-Voltage Ride Through","display_name":"Thermal Analysis of Multilevel Grid-Side Converters for 10-MW Wind Turbines Under Low-Voltage Ride Through","alternate_titles":[],"publication_year":2013,"publication_date":"2013-01-16","ids":{"openalex":"https://openalex.org/W2155777988","doi":"https://doi.org/10.1109/tia.2013.2240643","mag":"2155777988"},"language":"en","primary_location":{"id":"doi:10.1109/tia.2013.2240643","doi":"https://doi.org/10.1109/tia.2013.2240643","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tia.2013.2240643","pdf_url":null,"source":{"id":"https://openalex.org/S192268925","display_name":"IEEE Transactions on Industry Applications","issn_l":"0093-9994","issn":["0093-9994","1939-9367"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","jufo-2","ki-jl-1","norway-1","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industry Applications","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2155777988"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://vbn.aau.dk/ws/files/100586419/Thermal_Analysis_of_Multilevel_Grid_side_Converters_for_10_MW_Wind_turbines_under_Low_Voltage_Ride_Through.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5029142853","display_name":"Ke Ma","orcid":"https://orcid.org/0000-0002-8154-4354","observed_orcids":["https://orcid.org/0000-0002-8154-4354"]},"institutions":[{"id":"https://openalex.org/I891191580","display_name":"Aalborg University","ror":"https://ror.org/04m5j1k67","country_code":"DK","type":"education","lineage":["https://openalex.org/I891191580"]}],"countries":["DK"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Ke Ma","raw_affiliation_strings":["Institute of Energy Technology, Aalborg University, Aalborg, Denmark"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Energy Technology, Aalborg University, Aalborg, Denmark","institution_ids":["https://openalex.org/I891191580"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5039395705","display_name":"Frede Blaabjerg","orcid":"https://orcid.org/0000-0001-8311-7412","observed_orcids":["https://orcid.org/0000-0001-8311-7412"]},"institutions":[{"id":"https://openalex.org/I891191580","display_name":"Aalborg University","ror":"https://ror.org/04m5j1k67","country_code":"DK","type":"education","lineage":["https://openalex.org/I891191580"]}],"countries":["DK"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Frede Blaabjerg","raw_affiliation_strings":["Institute of Energy Technology, Aalborg University, Aalborg, Denmark"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Energy Technology, Aalborg University, Aalborg, Denmark","institution_ids":["https://openalex.org/I891191580"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5053880143","display_name":"Marco Liserre","orcid":"https://orcid.org/0000-0002-0818-2684","observed_orcids":["https://orcid.org/0000-0002-0818-2684"]},"institutions":[{"id":"https://openalex.org/I891191580","display_name":"Aalborg University","ror":"https://ror.org/04m5j1k67","country_code":"DK","type":"education","lineage":["https://openalex.org/I891191580"]}],"countries":["DK"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Marco Liserre","raw_affiliation_strings":["Institute of Energy Technology, Aalborg University, Aalborg, Denmark"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Energy Technology, Aalborg University, Aalborg, Denmark","institution_ids":["https://openalex.org/I891191580"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I891191580"],"apc_list":{"value":2645,"currency":"USD","value_usd":2645},"apc_paid":null,"fwci":5.6006,"has_fulltext":true,"cited_by_count":66,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.9630844,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":86,"max":99},"biblio":{"volume":"49","issue":"2","first_page":"909","last_page":"921"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9682999849319458,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9682999849319458,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.01860000006854534,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.00430000014603138,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/multilevel-converters","display_name":"multilevel converters","score":0.8690000176429749},{"id":"https://openalex.org/keywords/grid-side-converter","display_name":"grid-side converter","score":0.8619999885559082},{"id":"https://openalex.org/keywords/low-voltage-ride-through","display_name":"low-voltage ride-through","score":0.8600000143051147},{"id":"https://openalex.org/keywords/10-mw-wind-turbine","display_name":"10 MW wind turbine","score":0.9319999814033508},{"id":"https://openalex.org/keywords/junction-temperature","display_name":"junction temperature","score":0.753000020980835},{"id":"https://openalex.org/keywords/h-bridge-topology","display_name":"H-bridge topology","score":0.6880000233650208},{"id":"https://openalex.org/keywords/power-converter-reliability","display_name":"converter reliability","score":0.6779999732971191},{"id":"https://openalex.org/keywords/power-grid-faults","display_name":"grid faults","score":0.6809999942779541}],"concepts":[{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.6912667751312256},{"id":"https://openalex.org/C2780438294","wikidata":"https://www.wikidata.org/wiki/Q6693052","display_name":"Low voltage ride through","level":4,"score":0.5956448316574097},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5514932870864868},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.5436628460884094},{"id":"https://openalex.org/C199845137","wikidata":"https://www.wikidata.org/wiki/Q145490","display_name":"Network topology","level":2,"score":0.5316689014434814},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5089483261108398},{"id":"https://openalex.org/C145180747","wikidata":"https://www.wikidata.org/wiki/Q7236587","display_name":"Power optimizer","level":5,"score":0.4725624918937683},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.4453135132789612},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.43527457118034363},{"id":"https://openalex.org/C2778449969","wikidata":"https://www.wikidata.org/wiki/Q130760","display_name":"Turbine","level":2,"score":0.4312753975391388},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.4214334785938263},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.4039282202720642},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3953521251678467},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3895399570465088},{"id":"https://openalex.org/C36139824","wikidata":"https://www.wikidata.org/wiki/Q1052007","display_name":"Maximum power point tracking","level":4,"score":0.385320246219635},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.3622792959213257},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.33733314275741577},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.33250319957733154},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.08195394277572632},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/tia.2013.2240643","doi":"https://doi.org/10.1109/tia.2013.2240643","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tia.2013.2240643","pdf_url":null,"source":{"id":"https://openalex.org/S192268925","display_name":"IEEE Transactions on Industry Applications","issn_l":"0093-9994","issn":["0093-9994","1939-9367"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","jufo-2","ki-jl-1","norway-1","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industry Applications","raw_type":"journal-article"},{"id":"pmh:oai:pure.atira.dk:publications/424d2cb7-7104-4efc-9d66-cf1595327c3b","doi":null,"is_oa":true,"landing_page_url":"https://vbn.aau.dk/da/publications/424d2cb7-7104-4efc-9d66-cf1595327c3b","pdf_url":"https://vbn.aau.dk/ws/files/100586419/Thermal_Analysis_of_Multilevel_Grid_side_Converters_for_10_MW_Wind_turbines_under_Low_Voltage_Ride_Through.pdf","source":{"id":"https://openalex.org/S4306401731","display_name":"VBN Forskningsportal (Aalborg Universitet)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I891191580","host_organization_name":"Aalborg University","host_organization_lineage":["https://openalex.org/I891191580"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Ma, K, Blaabjerg, F & Liserre, M 2013, 'Thermal Analysis of Multilevel Grid-side Converters for 10-MW Wind turbines under Low-Voltage Ride Through', I E E E Transactions on Industry Applications, vol. 49, no. 2, pp. 909-921. https://doi.org/10.1109/TIA.2013.2240643","raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":{"id":"pmh:oai:pure.atira.dk:publications/424d2cb7-7104-4efc-9d66-cf1595327c3b","doi":null,"is_oa":true,"landing_page_url":"https://vbn.aau.dk/da/publications/424d2cb7-7104-4efc-9d66-cf1595327c3b","pdf_url":"https://vbn.aau.dk/ws/files/100586419/Thermal_Analysis_of_Multilevel_Grid_side_Converters_for_10_MW_Wind_turbines_under_Low_Voltage_Ride_Through.pdf","source":{"id":"https://openalex.org/S4306401731","display_name":"VBN Forskningsportal (Aalborg Universitet)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I891191580","host_organization_name":"Aalborg University","host_organization_lineage":["https://openalex.org/I891191580"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Ma, K, Blaabjerg, F & Liserre, M 2013, 'Thermal Analysis of Multilevel Grid-side Converters for 10-MW Wind turbines under Low-Voltage Ride Through', I E E E Transactions on Industry Applications, vol. 49, no. 2, pp. 909-921. https://doi.org/10.1109/TIA.2013.2240643","raw_type":"info:eu-repo/semantics/article"},"sustainable_development_goals":[{"score":1.0,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"},{"score":0.6773999929428101,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2155777988.pdf","grobid_xml":"https://content.openalex.org/works/W2155777988.grobid-xml"},"referenced_works_count":25,"referenced_works":["https://openalex.org/W1506097459","https://openalex.org/W1538244527","https://openalex.org/W1939068783","https://openalex.org/W1966683388","https://openalex.org/W1974259851","https://openalex.org/W2071324051","https://openalex.org/W2107763612","https://openalex.org/W2107852078","https://openalex.org/W2113748537","https://openalex.org/W2123828883","https://openalex.org/W2127485055","https://openalex.org/W2139389409","https://openalex.org/W2139772385","https://openalex.org/W2145731929","https://openalex.org/W2146048275","https://openalex.org/W2146058304","https://openalex.org/W2151341975","https://openalex.org/W2162030535","https://openalex.org/W2162448500","https://openalex.org/W2167033325","https://openalex.org/W2168643979","https://openalex.org/W2172175655","https://openalex.org/W2540103369","https://openalex.org/W3150660989","https://openalex.org/W3160421902"],"related_works":["https://openalex.org/W2421423517","https://openalex.org/W2551844405","https://openalex.org/W1977524549","https://openalex.org/W2142129448","https://openalex.org/W2032603453","https://openalex.org/W4390416902","https://openalex.org/W1506097459","https://openalex.org/W2110534007","https://openalex.org/W1965287768","https://openalex.org/W2390297779"],"abstract_inverted_index":{"As":[0],"the":[1,17,42,52,60,71,84,88,93,96,109,115,118,130,149,168,185,191,202,210],"power":[2,19,44,53,73,90,97,101,182],"level":[3,205],"of":[4,95,117,167,206],"a":[5,39],"single":[6],"wind":[7,18,43,89,133],"turbine":[8],"is":[9,37,152,163],"continuously":[10],"pushed":[11],"up":[12],"even":[13],"to":[14,24,30,57,59,82,200],"7":[15],"MW,":[16],"generation":[20,45],"systems":[21],"are":[22,76,135],"required":[23],"be":[25,48],"more":[26,49,78,80,198],"reliable":[27],"and":[28,55,79,112,137,193,204],"able":[29,56],"withstand":[31],"extreme":[32],"grid":[33,61,68,105],"disturbances.":[34],"Moreover,":[35,190],"it":[36],"becoming":[38,77],"need":[40],"that":[41,165],"system":[46],"should":[47],"active":[50],"in":[51,87,99,178],"network":[54],"contribute":[58],"recovery":[62],"by":[63],"injecting":[64],"reactive":[65],"current":[66],"during":[67,104],"faults.":[69],"Consequently,":[70],"full-scale":[72,100],"converter":[74,127,170],"solutions":[75],"popular":[81],"fulfill":[83],"growing":[85],"challenges":[86],"application.":[91],"Nevertheless,":[92],"loading":[94],"devices":[98,183],"converters,":[102],"particularly":[103],"faults,":[106],"may":[107],"compromise":[108],"reliability":[110],"performance":[111],"further":[113],"increase":[114],"cost":[116],"system.":[119],"In":[120],"this":[121],"paper,":[122],"three":[123],"promising":[124],"grid-side":[125],"multilevel":[126],"topologies":[128,171,196],"for":[129],"next-generation":[131],"10-MW":[132],"turbines":[134],"proposed":[136,169],"basically":[138],"designed":[139],"as":[140,146,148],"case":[141],"study.":[142],"The":[143],"operation":[144],"status,":[145],"well":[147],"reliability-related":[150],"performances,":[151],"investigated":[153],"aimed":[154],"at":[155],"various":[156],"low-voltage":[157],"ride":[158],"through":[159],"(LVRT)":[160],"conditions.":[161],"It":[162],"found":[164],"all":[166],"will":[172],"suffer":[173],"from":[174],"higher":[175],"junction":[176],"temperature":[177],"some":[179],"heavily":[180],"loaded":[181],"(particularly":[184],"diodes)":[186],"under":[187],"LVRT":[188],"operation.":[189],"three-level":[192,212],"five-level":[194],"H-bridge":[195],"show":[197],"potential":[199],"reduce":[201],"inequality":[203],"device":[207],"stress":[208],"than":[209],"well-known":[211],"neutral":[213],"point":[214],"clamped":[215],"topology.":[216]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2155777988","counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":5},{"year":2021,"cited_by_count":7},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":4},{"year":2018,"cited_by_count":5},{"year":2017,"cited_by_count":4},{"year":2016,"cited_by_count":9},{"year":2015,"cited_by_count":4},{"year":2014,"cited_by_count":11},{"year":2013,"cited_by_count":9},{"year":2012,"cited_by_count":3}],"updated_date":"2026-11-21T10:27:49.728292","created_date":"2016-06-24T00:00:00"}
