{"id":"https://openalex.org/W2154096790","doi":"https://doi.org/10.1109/mper.2002.4311847","title":"An Adaptive Scheme to Prevent Undesirable Distance Protection Operation during Voltage Instability","display_name":"An Adaptive Scheme to Prevent Undesirable Distance Protection Operation during Voltage Instability","alternate_titles":[],"publication_year":2002,"publication_date":"2002-11-01","ids":{"openalex":"https://openalex.org/W2154096790","doi":"https://doi.org/10.1109/mper.2002.4311847","mag":"2154096790"},"language":"en","primary_location":{"id":"doi:10.1109/mper.2002.4311847","doi":"https://doi.org/10.1109/mper.2002.4311847","is_oa":false,"landing_page_url":"https://doi.org/10.1109/mper.2002.4311847","pdf_url":null,"source":{"id":"https://openalex.org/S4210237175","display_name":"IEEE Power Engineering Review","issn_l":"0272-1724","issn":["0272-1724","1558-1705"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","norway-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Power Engineering Review","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2154096790"],"child_works_count":0,"pull_notice_works":[],"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"M. Jonsson","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I66862912","display_name":"Chalmers University of Technology","ror":"https://ror.org/040wg7k59","country_code":"SE","type":"education","lineage":["https://openalex.org/I66862912"]}],"countries":["SE"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"M. Jonsson","raw_affiliation_strings":["Chalmers University of Technology, Sweden"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Chalmers University of Technology, Sweden","institution_ids":["https://openalex.org/I66862912"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5006196650","display_name":"Jaap E. Daalder","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I66862912","display_name":"Chalmers University of Technology","ror":"https://ror.org/040wg7k59","country_code":"SE","type":"education","lineage":["https://openalex.org/I66862912"]}],"countries":["SE"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"J. Daalder","raw_affiliation_strings":["Chalmers University of Technology, Sweden"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Chalmers University of Technology, Sweden","institution_ids":["https://openalex.org/I66862912"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I66862912"],"apc_list":null,"apc_paid":null,"fwci":1.2121,"has_fulltext":false,"cited_by_count":66,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.7994995,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":99},"biblio":{"volume":"22","issue":"11","first_page":"61","last_page":"61"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.8335000276565552,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.8335000276565552,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.1655000001192093,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/distance-protection","display_name":"distance protection","score":0.9070000052452087},{"id":"https://openalex.org/keywords/voltage-instability","display_name":"voltage instability","score":0.9850000143051147},{"id":"https://openalex.org/keywords/rate-of-change-of-voltage","display_name":"rate of change of voltage","score":0.968999981880188},{"id":"https://openalex.org/keywords/power-system-collapse","display_name":"power system collapse","score":0.6710000038146973},{"id":"https://openalex.org/keywords/blackout-prevention","display_name":"blackout prevention","score":0.6539999842643738}],"concepts":[{"id":"https://openalex.org/C2778156585","wikidata":"https://www.wikidata.org/wiki/Q174053","display_name":"Relay","level":3,"score":0.8500254154205322},{"id":"https://openalex.org/C2777693866","wikidata":"https://www.wikidata.org/wiki/Q359099","display_name":"Blackout","level":4,"score":0.8442970514297485},{"id":"https://openalex.org/C207821765","wikidata":"https://www.wikidata.org/wiki/Q405372","display_name":"Instability","level":2,"score":0.7233772277832031},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6279313564300537},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.546436071395874},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.47390496730804443},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.37144696712493896},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2929793894290924},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.15937310457229614},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.11904516816139221},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/mper.2002.4311847","doi":"https://doi.org/10.1109/mper.2002.4311847","is_oa":false,"landing_page_url":"https://doi.org/10.1109/mper.2002.4311847","pdf_url":null,"source":{"id":"https://openalex.org/S4210237175","display_name":"IEEE Power Engineering Review","issn_l":"0272-1724","issn":["0272-1724","1558-1705"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","norway-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Power Engineering Review","raw_type":"journal-article"},{"id":"pmh:oai:publications.lib.chalmers.se:10360","doi":null,"is_oa":false,"landing_page_url":"http://publications.lib.chalmers.se/publication/10360-an-adaptive-scheme-to-prevent-undesirable-distance-protection-operation-during-voltage-instability","pdf_url":null,"source":{"id":"https://openalex.org/S4377196470","display_name":"Chalmers Publication Library (Chalmers University of Technology)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I66862912","host_organization_name":"Chalmers University of Technology","host_organization_lineage":["https://openalex.org/I66862912"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Text.Article.Journal.PeerReviewed"},{"id":"pmh:oai:research.chalmers.se:10360","doi":null,"is_oa":false,"landing_page_url":"https://research.chalmers.se/en/publication/10360","pdf_url":null,"source":{"id":"https://openalex.org/S4306402469","display_name":"Chalmers Research (Chalmers University of Technology)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I66862912","host_organization_name":"Chalmers University of Technology","host_organization_lineage":["https://openalex.org/I66862912"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.7207000255584717}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W2071344806","https://openalex.org/W2075632197","https://openalex.org/W2076433708","https://openalex.org/W2146687065"],"related_works":["https://openalex.org/W2120245302","https://openalex.org/W2101447226","https://openalex.org/W1992840562","https://openalex.org/W1991213482","https://openalex.org/W1999560353","https://openalex.org/W2118865147","https://openalex.org/W3008331014","https://openalex.org/W2529770170","https://openalex.org/W4417338507","https://openalex.org/W3135179155"],"abstract_inverted_index":{"An":[0],"adaptive":[1,96],"algorithm":[2,15,97,107],"to":[3,35,42,111],"prevent":[4],"undesirable":[5,70],"distance":[6,73,118],"protection":[7],"operations":[8,75],"during":[9,87],"voltage":[10,29,43,88,112],"instability":[11,113],"is":[12,16],"proposed.":[13],"The":[14,66],"based":[17,47],"on":[18,48],"mathematical":[19],"logic":[20],"blocks":[21],"and":[22,62,83],"uses":[23],"the":[24,37,60,63,78,95,100,106,114,117],"rate":[25],"of":[26,28,116],"change":[27],"as":[30],"an":[31],"additional":[32],"relay":[33,38,74,119],"criteria":[34],"increase":[36],"security":[39],"with":[40],"respect":[41],"instability.":[44,89],"Studies":[45],"are":[46],"simulations":[49,91],"using":[50],"two":[51],"different":[52],"test":[53],"systems:":[54],"a":[55,81,84,103],"15-bus":[56],"system":[57,86,101],"developed":[58],"by":[59],"authors":[61],"Nordic32":[64],"system.":[65],"investigation":[67],"shows":[68],"that":[69,94],"zone":[71],"3":[72],"can":[76],"be":[77,122],"difference":[79],"between":[80],"blackout":[82],"recovering":[85],"However,":[90],"have":[92],"shown":[93],"may":[98],"save":[99],"from":[102],"collapse.":[104],"Although":[105],"prevents":[108],"mal-trips":[109],"due":[110],"reach":[115],"will":[120],"not":[121],"restricted.":[123]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2154096790","counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2021,"cited_by_count":5},{"year":2020,"cited_by_count":7},{"year":2019,"cited_by_count":3},{"year":2018,"cited_by_count":2},{"year":2017,"cited_by_count":8},{"year":2016,"cited_by_count":10},{"year":2015,"cited_by_count":4},{"year":2014,"cited_by_count":6},{"year":2013,"cited_by_count":2},{"year":2012,"cited_by_count":3}],"updated_date":"2026-11-20T13:11:24.684918","created_date":"2016-06-24T00:00:00"}
