{"id":"https://openalex.org/W2152201252","doi":"https://doi.org/10.1049/cp:19950223","title":"Condition assessment techniques for large power transformers","display_name":"Condition assessment techniques for large power transformers","publication_year":1995,"publication_date":"1995-01-01","ids":{"openalex":"https://openalex.org/W2152201252","doi":"https://doi.org/10.1049/cp:19950223","mag":"2152201252"},"language":"en","primary_location":{"id":"doi:10.1049/cp:19950223","doi":"https://doi.org/10.1049/cp:19950223","is_oa":false,"landing_page_url":"https://doi.org/10.1049/cp:19950223","pdf_url":null,"source":{"id":"https://openalex.org/S7407105625","display_name":"IEE International Conference on Reliability of Transmission and Distribution Networks (RTDN)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4320800662","host_organization_name":"Institution of Electrical Engineers","host_organization_lineage":["https://openalex.org/P4320800662"],"host_organization_lineage_names":["Institution of Electrical Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Second International Conference on the Reliability of Transmission and Distribution Equipment","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5057645880","display_name":"J. A. Lapworth","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"J.A. Lapworth","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5057645880"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":16,"citation_normalized_percentile":{"value":0.36991171,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":95},"biblio":{"volume":"1995","issue":null,"first_page":"85","last_page":"90"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/condition-assessment","display_name":"condition assessment","score":0.8980000019073486},{"id":"https://openalex.org/keywords/power-transformers","display_name":"power transformers","score":0.9459999799728394},{"id":"https://openalex.org/keywords/transformer-reliability","display_name":"transformer reliability","score":0.5040000081062317},{"id":"https://openalex.org/keywords/asset-management","display_name":"asset management","score":0.6010000109672546},{"id":"https://openalex.org/keywords/condition-monitoring","display_name":"condition monitoring","score":0.6029999852180481},{"id":"https://openalex.org/keywords/diagnostic-testing","display_name":"diagnostic testing","score":0.5180000066757202},{"id":"https://openalex.org/keywords/trend-analysis","display_name":"trend analysis","score":0.6320000290870667},{"id":"https://openalex.org/keywords/electricity-sector","display_name":"electric utilities","score":0.4650000035762787},{"id":"https://openalex.org/keywords/capital-cost-reduction","display_name":"capital cost reduction","score":0.5199999809265137}],"concepts":[{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.7547727227210999},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.6511297821998596},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6312121152877808},{"id":"https://openalex.org/C2775846686","wikidata":"https://www.wikidata.org/wiki/Q643012","display_name":"Condition monitoring","level":2,"score":0.5383620858192444},{"id":"https://openalex.org/C112930515","wikidata":"https://www.wikidata.org/wiki/Q4389547","display_name":"Risk analysis (engineering)","level":1,"score":0.5307775735855103},{"id":"https://openalex.org/C2992893776","wikidata":"https://www.wikidata.org/wiki/Q955421","display_name":"Capital equipment","level":2,"score":0.4265681505203247},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3111359477043152},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.23016709089279175},{"id":"https://openalex.org/C117671659","wikidata":"https://www.wikidata.org/wiki/Q11049265","display_name":"Manufacturing engineering","level":1,"score":0.13954699039459229},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.13230210542678833},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1049/cp:19950223","doi":"https://doi.org/10.1049/cp:19950223","is_oa":false,"landing_page_url":"https://doi.org/10.1049/cp:19950223","pdf_url":null,"source":{"id":"https://openalex.org/S7407105625","display_name":"IEE International Conference on Reliability of Transmission and Distribution Networks (RTDN)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4320800662","host_organization_name":"Institution of Electrical Engineers","host_organization_lineage":["https://openalex.org/P4320800662"],"host_organization_lineage_names":["Institution of Electrical Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Second International Conference on the Reliability of Transmission and Distribution Equipment","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","score":0.7207000255584717,"display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W7221305250","https://openalex.org/W2034646051","https://openalex.org/W3198289631","https://openalex.org/W2890025291","https://openalex.org/W2542562327","https://openalex.org/W4405857509","https://openalex.org/W2582104326","https://openalex.org/W3152281767","https://openalex.org/W1987415035","https://openalex.org/W2539552458"],"abstract_inverted_index":{"An":[0],"important":[1],"task":[2],"for":[3,19,52,74],"electric":[4],"utilities":[5],"is":[6,40,49],"to":[7,103,113],"maintain":[8],"the":[9,17,28,33,60,68,123],"reliability":[10],"of":[11,32,65,87,125],"their":[12],"power":[13,53,76],"systems":[14],"whilst":[15],"minimising":[16],"necessity":[18],"capital":[20],"expenditure":[21],"on":[22,122],"asset":[23],"replacement.":[24],"To":[25],"achieve":[26],"this,":[27],"best":[29],"possible":[30],"knowledge":[31],"plant":[34],"condition":[35,71,81,97],"and":[36,47,89,95,105],"likely":[37],"future":[38],"problems":[39],"required.":[41],"Effective":[42],"assessment":[43,72,82,98],"techniques":[44,73,92],"are":[45,57,93],"required,":[46,94],"this":[48],"especially":[50],"so":[51],"transformers":[54],"since":[55],"these":[56],"very":[58],"often":[59],"single":[61],"most":[62],"expensive":[63],"items":[64],"plant.":[66],"Here,":[67],"authors":[69],"describe":[70],"such":[75],"transformers.":[77],"The":[78],"detail":[79],"how":[80,96],"encompasses":[83],"a":[84],"wide":[85],"range":[86],"activities":[88],"many":[90],"complementary":[91],"tests":[99],"should":[100,106,119],"be":[101,114],"easy":[102],"perform":[104],"provide":[107],"useful":[108],"information":[109],"from":[110],"one":[111],"test":[112],"cost":[115],"effective.":[116],"Ideally,":[117],"diagnoses":[118],"not":[120],"depend":[121],"analysis":[124],"trends.":[126]},"counts_by_year":[{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2014,"cited_by_count":1},{"year":2012,"cited_by_count":2}],"updated_date":"2026-10-28T10:33:24.094632","created_date":"2016-06-24T00:00:00"}
