{"id":"https://openalex.org/W2146353205","doi":null,"title":"Solar Panel Maximum Power Point Tracker for Power Utilities","display_name":"Solar Panel Maximum Power Point Tracker for Power Utilities","publication_year":2014,"publication_date":"2014-01-01","ids":{"openalex":"https://openalex.org/W2146353205","mag":"2146353205"},"language":"en","primary_location":{"id":"mag:2146353205","doi":null,"is_oa":false,"landing_page_url":"https://doaj.org/article/caec6ed82c194d588acd57f788f96a54","pdf_url":null,"source":{"id":"https://openalex.org/S2739325770","display_name":"International Journal of Engineering Research and Applications","issn_l":"2248-9622","issn":["2248-9622"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"International Journal of Engineering Research and Applications","raw_type":null},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Sandeep Banik","orcid":"https://orcid.org/0000-0001-9949-7173","observed_orcids":["https://orcid.org/0000-0001-9949-7173"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Sandeep Banik","raw_affiliation_strings":[],"raw_orcid":"https://orcid.org/0000-0001-9949-7173","affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5101934674","display_name":"Pradip Kumar Saha","orcid":"https://orcid.org/0000-0001-8453-5659","observed_orcids":["https://orcid.org/0000-0001-8453-5659"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Pradip Kumar Saha","raw_affiliation_strings":[],"raw_orcid":"https://orcid.org/0000-0001-8453-5659","affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.15523256,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"4","issue":"1","first_page":"71","last_page":"75"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10468","display_name":"Photovoltaic System Optimization Techniques","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10468","display_name":"Photovoltaic System Optimization Techniques","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/maximum-power-point-tracking","display_name":"maximum power point tracking","score":0.9940000176429749},{"id":"https://openalex.org/keywords/photovoltaic-arrays","display_name":"photovoltaic arrays","score":0.8330000042915344},{"id":"https://openalex.org/keywords/solar-energy","display_name":"solar energy","score":0.5709999799728394},{"id":"https://openalex.org/keywords/switching-converters","display_name":"switching converters","score":0.625},{"id":"https://openalex.org/keywords/inverter","display_name":"inverter","score":0.968999981880188},{"id":"https://openalex.org/keywords/dc-ac-conversion","display_name":"DC-AC conversion","score":0.8140000104904175},{"id":"https://openalex.org/keywords/electricity-sector","display_name":"electric utilities","score":0.671999990940094}],"concepts":[{"id":"https://openalex.org/C36139824","wikidata":"https://www.wikidata.org/wiki/Q1052007","display_name":"Maximum power point tracking","level":4,"score":0.9199014902114868},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.8403131365776062},{"id":"https://openalex.org/C116615679","wikidata":"https://www.wikidata.org/wiki/Q6795908","display_name":"Maximum power principle","level":3,"score":0.7529802322387695},{"id":"https://openalex.org/C145180747","wikidata":"https://www.wikidata.org/wiki/Q7236587","display_name":"Power optimizer","level":5,"score":0.6320024728775024},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.5654609203338623},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5547335743904114},{"id":"https://openalex.org/C195697387","wikidata":"https://www.wikidata.org/wiki/Q5608561","display_name":"Grid-connected photovoltaic power system","level":5,"score":0.5010442733764648},{"id":"https://openalex.org/C53954817","wikidata":"https://www.wikidata.org/wiki/Q7556716","display_name":"Solar micro-inverter","level":5,"score":0.47857168316841125},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4599742889404297},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4328845143318176},{"id":"https://openalex.org/C151799858","wikidata":"https://www.wikidata.org/wiki/Q587008","display_name":"Switched-mode power supply","level":3,"score":0.42257049679756165},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.38619813323020935},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3387046456336975},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3087635338306427},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.20458155870437622},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:2146353205","doi":null,"is_oa":false,"landing_page_url":"https://doaj.org/article/caec6ed82c194d588acd57f788f96a54","pdf_url":null,"source":{"id":"https://openalex.org/S2739325770","display_name":"International Journal of Engineering Research and Applications","issn_l":"2248-9622","issn":["2248-9622"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"International Journal of Engineering Research and Applications","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.9853000044822693,"id":"https://metadata.un.org/sdg/7"},{"display_name":"Industry, innovation and infrastructure","score":0.6773999929428101,"id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":3,"referenced_works":["https://openalex.org/W1590926527","https://openalex.org/W2098487547","https://openalex.org/W2184869874"],"related_works":["https://openalex.org/W2039580481","https://openalex.org/W2165280097","https://openalex.org/W7220191378","https://openalex.org/W4380201329","https://openalex.org/W2518108079","https://openalex.org/W2799984333","https://openalex.org/W2917345325","https://openalex.org/W2330898168","https://openalex.org/W6996840249","https://openalex.org/W2109520446"],"abstract_inverted_index":{"\u2015Solar":[0],"Panel":[1],"Maximum":[2],"Power":[3],"Point":[4],"Tracker":[5],"For":[6],"power":[7,28,44,58,72,109],"utilities\u2016":[8],"As":[9],"the":[10,20,42,50,66,97],"name":[11],"implied,":[12],"it":[13],"is":[14,62,80],"a":[15,24,83],"photovoltaic":[16,21,33,84],"system":[17],"that":[18],"uses":[19],"array":[22,35,54,68,86],"as":[23],"source":[25],"of":[26,76],"electrical":[27],"supply":[29],"and":[30,53,111],"since":[31],"every":[32],"(PV)":[34,85],"has":[36],"an":[37],"optimum":[38],"operating":[39],"point,":[40,45],"called":[41],"maximum":[43,57,71],"which":[46],"varies":[47],"depending":[48],"on":[49],"insolation":[51],"level":[52],"voltage.":[55],"A":[56],"point":[59],"tracker":[60],"(MPPT)":[61],"needed":[63],"to":[64,81,100],"operate":[65],"PV":[67],"at":[69],"its":[70],"point.":[73],"The":[74],"objective":[75],"this":[77],"thesis":[78],"project":[79],"build":[82],"Of":[87],"121.6V":[88],"DC":[89,98],"Voltage(6":[90],"cell":[91],"each":[92],"20V,":[93],"100watt)":[94],"And":[95],"convert":[96],"voltage":[99,105],"Single":[101],"phase":[102],"120v,50Hz":[103],"AC":[104],"by":[106],"switch":[107],"mode":[108],"converter\u2018s":[110],"inverter\u2018s.":[112]},"counts_by_year":[],"updated_date":"2026-09-29T14:09:16.559479","created_date":"2016-06-24T00:00:00"}
