{"id":"https://openalex.org/W2145666117","doi":"https://doi.org/10.1109/elinsl.2000.845534","title":"On-site investigations of gas insulated substations using ion mobility spectrometry for remote sensing of SF/sub 6/ decomposition","display_name":"On-site investigations of gas insulated substations using ion mobility spectrometry for remote sensing of SF/sub 6/ decomposition","publication_year":2002,"publication_date":"2002-11-07","ids":{"openalex":"https://openalex.org/W2145666117","doi":"https://doi.org/10.1109/elinsl.2000.845534","mag":"2145666117"},"language":"en","primary_location":{"id":"doi:10.1109/elinsl.2000.845534","doi":"https://doi.org/10.1109/elinsl.2000.845534","is_oa":false,"landing_page_url":"https://doi.org/10.1109/elinsl.2000.845534","pdf_url":null,"source":{"id":"https://openalex.org/S4306418757","display_name":"IEEE International Symposium on Electrical Insulation","issn_l":"0164-2006","issn":["0164-2006"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Conference Record of the 2000 IEEE International Symposium on Electrical Insulation (Cat. No.00CH37075)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5068460285","display_name":"P. Pilzecker","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"P. Pilzecker","raw_affiliation_strings":["TechnologieZentrum Dortmund, Gesellschaft f\u00fcr analytische SensorSysteme GmbH, Dortmund, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"TechnologieZentrum Dortmund, Gesellschaft f\u00fcr analytische SensorSysteme GmbH, Dortmund, Germany","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5111711254","display_name":"J. I. Baumbach","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210121365","display_name":"Leibniz Institute for Analytical Sciences - ISAS","ror":"https://ror.org/02jhqqg57","country_code":"DE","type":"facility","lineage":["https://openalex.org/I315704651","https://openalex.org/I4210121365"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"J.I. Baumbach","raw_affiliation_strings":["Institut f\u00fcr Spektrochemie und Angewandte Spektroskopie, Dortmund, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institut f\u00fcr Spektrochemie und Angewandte Spektroskopie, Dortmund, Germany","institution_ids":["https://openalex.org/I4210121365"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5108446673","display_name":"Eduardo Marques Trindade","orcid":"https://orcid.org/0000-0003-4929-5973","observed_orcids":["https://orcid.org/0000-0003-4929-5973"]},"institutions":[{"id":"https://openalex.org/I52418104","display_name":"Universidade Federal do Paran\u00e1","ror":"https://ror.org/05syd6y78","country_code":"BR","type":"education","lineage":["https://openalex.org/I52418104"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"E. Trindade","raw_affiliation_strings":["Laborat\u00f3drio Central de Pesquisa e Desenvolvimento Copel/UFPR, Curitiba, Parana, Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Laborat\u00f3drio Central de Pesquisa e Desenvolvimento Copel/UFPR, Curitiba, Parana, Brazil","institution_ids":["https://openalex.org/I52418104"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":3.0147,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.90850934,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"98","issue":null,"first_page":"400","last_page":"403"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.5913000106811523,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.5913000106811523,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10683","display_name":"Mass Spectrometry Techniques and Applications","score":0.2502000033855438,"subfield":{"id":"https://openalex.org/subfields/1607","display_name":"Spectroscopy"},"field":{"id":"https://openalex.org/fields/16","display_name":"Chemistry"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11111","display_name":"Spectroscopy and Laser Applications","score":0.014499999582767487,"subfield":{"id":"https://openalex.org/subfields/1607","display_name":"Spectroscopy"},"field":{"id":"https://openalex.org/fields/16","display_name":"Chemistry"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/gas-insulated-substations","display_name":"gas-insulated substations","score":0.8600000143051147},{"id":"https://openalex.org/keywords/sf6-decomposition","display_name":"SF6 decomposition","score":0.8230000138282776},{"id":"https://openalex.org/keywords/ion-mobility-spectrometry","display_name":"ion mobility spectrometry","score":0.9539999961853027},{"id":"https://openalex.org/keywords/partial-discharge","display_name":"partial discharge","score":0.628000020980835},{"id":"https://openalex.org/keywords/sf6-circuit-breakers","display_name":"SF6 circuit breakers","score":0.8190000057220459},{"id":"https://openalex.org/keywords/field-monitoring","display_name":"field monitoring","score":0.6930000185966492},{"id":"https://openalex.org/keywords/remote-sensing","display_name":"remote sensing","score":0.7540000081062317},{"id":"https://openalex.org/keywords/gas-insulated-switchgear","display_name":"gas-insulated switchgear","score":0.6470000147819519},{"id":"https://openalex.org/keywords/itaipu-binacional","display_name":"Itaipu Binacional","score":0.6850000023841858},{"id":"https://openalex.org/keywords/foz-do-iguacu","display_name":"Foz do Igua\u00e7u","score":0.8489999771118164},{"id":"https://openalex.org/keywords/hydroelectric-power-plant","display_name":"hydroelectric power plant","score":0.7099999785423279}],"concepts":[{"id":"https://openalex.org/C93893174","wikidata":"https://www.wikidata.org/wiki/Q1273786","display_name":"Switchgear","level":2,"score":0.9272780418395996},{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.908359169960022},{"id":"https://openalex.org/C92311004","wikidata":"https://www.wikidata.org/wiki/Q80638","display_name":"Hydroelectricity","level":2,"score":0.6656123995780945},{"id":"https://openalex.org/C2778282533","wikidata":"https://www.wikidata.org/wiki/Q279055","display_name":"Sulfur hexafluoride","level":2,"score":0.6149530410766602},{"id":"https://openalex.org/C119224816","wikidata":"https://www.wikidata.org/wiki/Q5274910","display_name":"Dielectric gas","level":2,"score":0.589066207408905},{"id":"https://openalex.org/C130143024","wikidata":"https://www.wikidata.org/wiki/Q1929972","display_name":"Partial discharge","level":3,"score":0.5709829926490784},{"id":"https://openalex.org/C15213710","wikidata":"https://www.wikidata.org/wiki/Q904207","display_name":"Ion-mobility spectrometry","level":3,"score":0.5532391667366028},{"id":"https://openalex.org/C124681953","wikidata":"https://www.wikidata.org/wiki/Q339062","display_name":"Decomposition","level":2,"score":0.5141173005104065},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.505204975605011},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4831399619579315},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.47955724596977234},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.47310781478881836},{"id":"https://openalex.org/C4311470","wikidata":"https://www.wikidata.org/wiki/Q159719","display_name":"Power station","level":2,"score":0.4684106707572937},{"id":"https://openalex.org/C162175671","wikidata":"https://www.wikidata.org/wiki/Q3749263","display_name":"Electrical equipment","level":2,"score":0.4263724386692047},{"id":"https://openalex.org/C3018541784","wikidata":"https://www.wikidata.org/wiki/Q5526318","display_name":"Gas analysis","level":2,"score":0.42014509439468384},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.3928043842315674},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3218955397605896},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.30697402358055115},{"id":"https://openalex.org/C116915560","wikidata":"https://www.wikidata.org/wiki/Q83504","display_name":"Nuclear engineering","level":1,"score":0.27723729610443115},{"id":"https://openalex.org/C162356407","wikidata":"https://www.wikidata.org/wiki/Q180809","display_name":"Mass spectrometry","level":2,"score":0.19732573628425598},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.1273430585861206},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.1165851354598999},{"id":"https://openalex.org/C178790620","wikidata":"https://www.wikidata.org/wiki/Q11351","display_name":"Organic chemistry","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/elinsl.2000.845534","doi":"https://doi.org/10.1109/elinsl.2000.845534","is_oa":false,"landing_page_url":"https://doi.org/10.1109/elinsl.2000.845534","pdf_url":null,"source":{"id":"https://openalex.org/S4306418757","display_name":"IEEE International Symposium on Electrical Insulation","issn_l":"0164-2006","issn":["0164-2006"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Conference Record of the 2000 IEEE International Symposium on Electrical Insulation (Cat. No.00CH37075)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8970999717712402,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":9,"referenced_works":["https://openalex.org/W1590250728","https://openalex.org/W1988665829","https://openalex.org/W1997166043","https://openalex.org/W2021713537","https://openalex.org/W2047374213","https://openalex.org/W2068260381","https://openalex.org/W2149057066","https://openalex.org/W2291837249","https://openalex.org/W4206689559"],"related_works":["https://openalex.org/W2146818823","https://openalex.org/W1900170337","https://openalex.org/W2291837249","https://openalex.org/W2034781948","https://openalex.org/W1567653419","https://openalex.org/W2164131358","https://openalex.org/W2143856681","https://openalex.org/W1764347934","https://openalex.org/W2535909520","https://openalex.org/W2391085632"],"abstract_inverted_index":{"Although":[0],"gas":[1,46],"insulated":[2],"switchgear":[3],"and":[4,30,67,81,101],"substations":[5],"(GIS)":[6],"belong":[7],"to":[8,63],"the":[9,38,44,72,93,110,129,142],"most":[10],"reliable":[11],"components":[12],"of":[13,40,43,71,78,84,92,107,109,113,124,131,138,146,151],"electric":[14],"power":[15,57,95,144],"networks,":[16],"failures":[17],"still":[18],"occur":[19],"in":[20,88,121,141],"their":[21],"long":[22],"term":[23],"operation.":[24],"A":[25],"monitoring":[26,66,80],"system":[27,133],"for":[28,134],"GIS":[29],"SF/sub":[31,73,85,139],"6/-filled":[32],"circuit":[33,90,116],"breakers":[34,117],"is":[35,154],"realised":[36],"on":[37],"basis":[39],"continuous":[41],"sensing":[42,137],"insulating":[45],"using":[47],"ion":[48],"mobility":[49],"spectrometers":[50],"(IMS).":[51],"Especially,":[52],"partial":[53],"discharge":[54],"IMS":[55],"provides":[56],"utilities":[58],"a":[59,89,122,132],"diagnostic":[60],"tool":[61],"able":[62],"perform":[64],"on-site":[65,79,136],"event":[68],"controlled":[69],"inspections":[70],"6/":[74,86],"gas.":[75],"The":[76],"results":[77],"on-line":[82],"analyse":[83],"contained":[87],"breaker":[91],"hydroelectric":[94,143],"plant":[96,145],"Itaipu":[97,125],"Binacional,":[98],"Brazil,":[99,153],"before":[100],"after":[102],"operation":[103],"are":[104,126],"described.":[105],"Conclusions":[106],"investigations":[108],"actual":[111],"state":[112],"36":[114],"different":[115],"executed":[118],"under":[119],"service":[120],"substation":[123],"presented.":[127],"Finally,":[128],"structure":[130],"automatic":[135],"6/-decomposition":[140],"Foz":[147],"do":[148],"Areia,":[149],"State":[150],"Parana":[152],"discussed.":[155]},"counts_by_year":[{"year":2013,"cited_by_count":1}],"updated_date":"2026-10-06T10:28:23.643775","created_date":"2016-06-24T00:00:00"}