{"id":"https://openalex.org/W2145114963","doi":"https://doi.org/10.1061/(asce)0733-9496(2005)131:4(316)","title":"Pipeline Break Detection Using Pressure Transient Monitoring","display_name":"Pipeline Break Detection Using Pressure Transient Monitoring","alternate_titles":[],"publication_year":2005,"publication_date":"2005-06-16","ids":{"openalex":"https://openalex.org/W2145114963","doi":"https://doi.org/10.1061/(asce)0733-9496(2005)131:4(316)","mag":"2145114963"},"language":"en","primary_location":{"id":"doi:10.1061/(asce)0733-9496(2005)131:4(316)","doi":"https://doi.org/10.1061/(asce)0733-9496(2005)131:4(316)","is_oa":false,"landing_page_url":"https://doi.org/10.1061/(asce)0733-9496(2005)131:4(316)","pdf_url":null,"source":{"id":"https://openalex.org/S127754761","display_name":"Journal of Water Resources Planning and Management","issn_l":"0733-9496","issn":["0733-9496","1943-5452"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-1","norway-1","poland-140","russia-white-list-1"],"host_organization":"https://openalex.org/P4310315747","host_organization_name":"American Society of Civil Engineers","host_organization_lineage":["https://openalex.org/P4310315747"],"host_organization_lineage_names":["American Society of Civil Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Water Resources Planning and Management","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2145114963"],"child_works_count":0,"pull_notice_works":[],"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5083302501","display_name":"Dalius Misi\u016bnas","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I187531555","display_name":"Lund University","ror":"https://ror.org/012a77v79","country_code":"SE","type":"education","lineage":["https://openalex.org/I187531555"]},{"id":"https://openalex.org/I5681781","display_name":"The University of Adelaide","ror":"https://ror.org/00892tw58","country_code":"AU","type":"education","lineage":["https://openalex.org/I4405259444","https://openalex.org/I5681781"]}],"countries":["AU","SE"],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"Dalius Misiunas","raw_affiliation_strings":["Associate Professor, Head of School of Civil and Environmental Engineering, Univ. of Adelaide, Adelaide SA 5005, Australia","Graduate Engineer, Water Solutions Pty Ltd, P.O. Box 1031, Kenmore, Qld., 4069, Australia","PhD Candidate, Dept. of Industrial Electrical Engineering and Automation, Lund Univ., P.O. Box 118, SE - 221 00, Lund, Sweden (corresponding author)","Professor, Dept. of Industrial Electrical Engineering and Automation, Lund Univ., P.O. Box 118, SE - 221 00, Lund, Sweden","Senior Lecturer, School of Civil and Environmental Engineering, Univ. of Adelaide, Adelaide SA 5005, Australia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Associate Professor, Head of School of Civil and Environmental Engineering, Univ. of Adelaide, Adelaide SA 5005, Australia","institution_ids":["https://openalex.org/I5681781"]},{"raw_affiliation_string":"Graduate Engineer, Water Solutions Pty Ltd, P.O. Box 1031, Kenmore, Qld., 4069, Australia","institution_ids":[]},{"raw_affiliation_string":"PhD Candidate, Dept. of Industrial Electrical Engineering and Automation, Lund Univ., P.O. Box 118, SE - 221 00, Lund, Sweden (corresponding author)","institution_ids":["https://openalex.org/I187531555"]},{"raw_affiliation_string":"Professor, Dept. of Industrial Electrical Engineering and Automation, Lund Univ., P.O. Box 118, SE - 221 00, Lund, Sweden","institution_ids":["https://openalex.org/I187531555"]},{"raw_affiliation_string":"Senior Lecturer, School of Civil and Environmental Engineering, Univ. of Adelaide, Adelaide SA 5005, Australia","institution_ids":["https://openalex.org/I5681781"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5036061213","display_name":"John P. V\u00edtkovsk\u00fd","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I187531555","display_name":"Lund University","ror":"https://ror.org/012a77v79","country_code":"SE","type":"education","lineage":["https://openalex.org/I187531555"]},{"id":"https://openalex.org/I5681781","display_name":"The University of Adelaide","ror":"https://ror.org/00892tw58","country_code":"AU","type":"education","lineage":["https://openalex.org/I4405259444","https://openalex.org/I5681781"]}],"countries":["AU","SE"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"John V\u00edtkovsk\u00fd","raw_affiliation_strings":["Associate Professor, Head of School of Civil and Environmental Engineering, Univ. of Adelaide, Adelaide SA 5005, Australia","Graduate Engineer, Water Solutions Pty Ltd, P.O. Box 1031, Kenmore, Qld., 4069, Australia","PhD Candidate, Dept. of Industrial Electrical Engineering and Automation, Lund Univ., P.O. Box 118, SE - 221 00, Lund, Sweden (corresponding author)","Professor, Dept. of Industrial Electrical Engineering and Automation, Lund Univ., P.O. Box 118, SE - 221 00, Lund, Sweden","Senior Lecturer, School of Civil and Environmental Engineering, Univ. of Adelaide, Adelaide SA 5005, Australia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Associate Professor, Head of School of Civil and Environmental Engineering, Univ. of Adelaide, Adelaide SA 5005, Australia","institution_ids":["https://openalex.org/I5681781"]},{"raw_affiliation_string":"Graduate Engineer, Water Solutions Pty Ltd, P.O. Box 1031, Kenmore, Qld., 4069, Australia","institution_ids":[]},{"raw_affiliation_string":"PhD Candidate, Dept. of Industrial Electrical Engineering and Automation, Lund Univ., P.O. Box 118, SE - 221 00, Lund, Sweden (corresponding author)","institution_ids":["https://openalex.org/I187531555"]},{"raw_affiliation_string":"Professor, Dept. of Industrial Electrical Engineering and Automation, Lund Univ., P.O. Box 118, SE - 221 00, Lund, Sweden","institution_ids":["https://openalex.org/I187531555"]},{"raw_affiliation_string":"Senior Lecturer, School of Civil and Environmental Engineering, Univ. of Adelaide, Adelaide SA 5005, Australia","institution_ids":["https://openalex.org/I5681781"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5102982345","display_name":"Gustaf Olsson","type":null,"orcid":"https://orcid.org/0000-0002-7677-1886","observed_orcids":["https://orcid.org/0000-0002-7677-1886"]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I187531555","display_name":"Lund University","ror":"https://ror.org/012a77v79","country_code":"SE","type":"education","lineage":["https://openalex.org/I187531555"]},{"id":"https://openalex.org/I5681781","display_name":"The University of Adelaide","ror":"https://ror.org/00892tw58","country_code":"AU","type":"education","lineage":["https://openalex.org/I4405259444","https://openalex.org/I5681781"]}],"countries":["AU","SE"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Gustaf Olsson","raw_affiliation_strings":["Associate Professor, Head of School of Civil and Environmental Engineering, Univ. of Adelaide, Adelaide SA 5005, Australia","Graduate Engineer, Water Solutions Pty Ltd, P.O. Box 1031, Kenmore, Qld., 4069, Australia","PhD Candidate, Dept. of Industrial Electrical Engineering and Automation, Lund Univ., P.O. Box 118, SE - 221 00, Lund, Sweden (corresponding author)","Professor, Dept. of Industrial Electrical Engineering and Automation, Lund Univ., P.O. Box 118, SE - 221 00, Lund, Sweden","Senior Lecturer, School of Civil and Environmental Engineering, Univ. of Adelaide, Adelaide SA 5005, Australia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Associate Professor, Head of School of Civil and Environmental Engineering, Univ. of Adelaide, Adelaide SA 5005, Australia","institution_ids":["https://openalex.org/I5681781"]},{"raw_affiliation_string":"Graduate Engineer, Water Solutions Pty Ltd, P.O. Box 1031, Kenmore, Qld., 4069, Australia","institution_ids":[]},{"raw_affiliation_string":"PhD Candidate, Dept. of Industrial Electrical Engineering and Automation, Lund Univ., P.O. Box 118, SE - 221 00, Lund, Sweden (corresponding author)","institution_ids":["https://openalex.org/I187531555"]},{"raw_affiliation_string":"Professor, Dept. of Industrial Electrical Engineering and Automation, Lund Univ., P.O. Box 118, SE - 221 00, Lund, Sweden","institution_ids":["https://openalex.org/I187531555"]},{"raw_affiliation_string":"Senior Lecturer, School of Civil and Environmental Engineering, Univ. of Adelaide, Adelaide SA 5005, Australia","institution_ids":["https://openalex.org/I5681781"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5051380741","display_name":"Angus Ross Simpson","type":null,"orcid":"https://orcid.org/0000-0003-1633-0111","observed_orcids":["https://orcid.org/0000-0003-1633-0111"]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I187531555","display_name":"Lund University","ror":"https://ror.org/012a77v79","country_code":"SE","type":"education","lineage":["https://openalex.org/I187531555"]},{"id":"https://openalex.org/I5681781","display_name":"The University of Adelaide","ror":"https://ror.org/00892tw58","country_code":"AU","type":"education","lineage":["https://openalex.org/I4405259444","https://openalex.org/I5681781"]}],"countries":["AU","SE"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Angus Simpson","raw_affiliation_strings":["Associate Professor, Head of School of Civil and Environmental Engineering, Univ. of Adelaide, Adelaide SA 5005, Australia","Graduate Engineer, Water Solutions Pty Ltd, P.O. Box 1031, Kenmore, Qld., 4069, Australia","PhD Candidate, Dept. of Industrial Electrical Engineering and Automation, Lund Univ., P.O. Box 118, SE - 221 00, Lund, Sweden (corresponding author)","Professor, Dept. of Industrial Electrical Engineering and Automation, Lund Univ., P.O. Box 118, SE - 221 00, Lund, Sweden","Senior Lecturer, School of Civil and Environmental Engineering, Univ. of Adelaide, Adelaide SA 5005, Australia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Associate Professor, Head of School of Civil and Environmental Engineering, Univ. of Adelaide, Adelaide SA 5005, Australia","institution_ids":["https://openalex.org/I5681781"]},{"raw_affiliation_string":"Graduate Engineer, Water Solutions Pty Ltd, P.O. Box 1031, Kenmore, Qld., 4069, Australia","institution_ids":[]},{"raw_affiliation_string":"PhD Candidate, Dept. of Industrial Electrical Engineering and Automation, Lund Univ., P.O. Box 118, SE - 221 00, Lund, Sweden (corresponding author)","institution_ids":["https://openalex.org/I187531555"]},{"raw_affiliation_string":"Professor, Dept. of Industrial Electrical Engineering and Automation, Lund Univ., P.O. Box 118, SE - 221 00, Lund, Sweden","institution_ids":["https://openalex.org/I187531555"]},{"raw_affiliation_string":"Senior Lecturer, School of Civil and Environmental Engineering, Univ. of Adelaide, Adelaide SA 5005, Australia","institution_ids":["https://openalex.org/I5681781"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5032732957","display_name":"Martin Francis Lambert","type":null,"orcid":"https://orcid.org/0000-0001-8272-6697","observed_orcids":["https://orcid.org/0000-0001-8272-6697"]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I187531555","display_name":"Lund University","ror":"https://ror.org/012a77v79","country_code":"SE","type":"education","lineage":["https://openalex.org/I187531555"]},{"id":"https://openalex.org/I5681781","display_name":"The University of Adelaide","ror":"https://ror.org/00892tw58","country_code":"AU","type":"education","lineage":["https://openalex.org/I4405259444","https://openalex.org/I5681781"]}],"countries":["AU","SE"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Martin Lambert","raw_affiliation_strings":["Associate Professor, Head of School of Civil and Environmental Engineering, Univ. of Adelaide, Adelaide SA 5005, Australia","Graduate Engineer, Water Solutions Pty Ltd, P.O. Box 1031, Kenmore, Qld., 4069, Australia","PhD Candidate, Dept. of Industrial Electrical Engineering and Automation, Lund Univ., P.O. Box 118, SE - 221 00, Lund, Sweden (corresponding author)","Professor, Dept. of Industrial Electrical Engineering and Automation, Lund Univ., P.O. Box 118, SE - 221 00, Lund, Sweden","Senior Lecturer, School of Civil and Environmental Engineering, Univ. of Adelaide, Adelaide SA 5005, Australia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Associate Professor, Head of School of Civil and Environmental Engineering, Univ. of Adelaide, Adelaide SA 5005, Australia","institution_ids":["https://openalex.org/I5681781"]},{"raw_affiliation_string":"Graduate Engineer, Water Solutions Pty Ltd, P.O. Box 1031, Kenmore, Qld., 4069, Australia","institution_ids":[]},{"raw_affiliation_string":"PhD Candidate, Dept. of Industrial Electrical Engineering and Automation, Lund Univ., P.O. Box 118, SE - 221 00, Lund, Sweden (corresponding author)","institution_ids":["https://openalex.org/I187531555"]},{"raw_affiliation_string":"Professor, Dept. of Industrial Electrical Engineering and Automation, Lund Univ., P.O. Box 118, SE - 221 00, Lund, Sweden","institution_ids":["https://openalex.org/I187531555"]},{"raw_affiliation_string":"Senior Lecturer, School of Civil and Environmental Engineering, Univ. of Adelaide, Adelaide SA 5005, Australia","institution_ids":["https://openalex.org/I5681781"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5083302501"],"corresponding_institution_ids":["https://openalex.org/I187531555","https://openalex.org/I5681781"],"apc_list":null,"apc_paid":null,"fwci":9.3652,"has_fulltext":false,"cited_by_count":143,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.96838556,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":96,"max":99},"biblio":{"volume":"131","issue":"4","first_page":"316","last_page":"325"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11220","display_name":"Water Systems and Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11220","display_name":"Water Systems and Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12086","display_name":"Structural Integrity and Reliability Analysis","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/water-transmission-pipelines","display_name":"water transmission pipelines","score":0.8479999899864197},{"id":"https://openalex.org/keywords/negative-pressure-wave","display_name":"negative pressure wave","score":0.6819999814033508},{"id":"https://openalex.org/keywords/pressure-wave-reflection","display_name":"pressure wave reflection","score":0.6570000052452087},{"id":"https://openalex.org/keywords/cusum-algorithm","display_name":"CUSUM algorithm","score":0.7870000004768372},{"id":"https://openalex.org/keywords/parameter-adaptation","display_name":"parameter adaptation","score":0.7910000085830688},{"id":"https://openalex.org/keywords/continuous-monitoring","display_name":"continuous monitoring","score":0.6050000190734863}],"concepts":[{"id":"https://openalex.org/C175309249","wikidata":"https://www.wikidata.org/wiki/Q725864","display_name":"Pipeline transport","level":2,"score":0.7853965163230896},{"id":"https://openalex.org/C178518018","wikidata":"https://www.wikidata.org/wiki/Q1024555","display_name":"CUSUM","level":2,"score":0.7139307260513306},{"id":"https://openalex.org/C43521106","wikidata":"https://www.wikidata.org/wiki/Q2165493","display_name":"Pipeline (software)","level":2,"score":0.668380081653595},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.6621496677398682},{"id":"https://openalex.org/C2776902269","wikidata":"https://www.wikidata.org/wiki/Q5165493","display_name":"Continuous monitoring","level":2,"score":0.4305422306060791},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3964293599128723},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.3710709810256958},{"id":"https://openalex.org/C199104240","wikidata":"https://www.wikidata.org/wiki/Q118291","display_name":"Marine engineering","level":1,"score":0.35365423560142517},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3048369288444519},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.09803140163421631},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1061/(asce)0733-9496(2005)131:4(316)","doi":"https://doi.org/10.1061/(asce)0733-9496(2005)131:4(316)","is_oa":false,"landing_page_url":"https://doi.org/10.1061/(asce)0733-9496(2005)131:4(316)","pdf_url":null,"source":{"id":"https://openalex.org/S127754761","display_name":"Journal of Water Resources Planning and Management","issn_l":"0733-9496","issn":["0733-9496","1943-5452"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-1","norway-1","poland-140","russia-white-list-1"],"host_organization":"https://openalex.org/P4310315747","host_organization_name":"American Society of Civil Engineers","host_organization_lineage":["https://openalex.org/P4310315747"],"host_organization_lineage_names":["American Society of Civil Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Water Resources Planning and Management","raw_type":"journal-article"},{"id":"pmh:oai:digital.library.adelaide.edu.au:2440/16741","doi":null,"is_oa":false,"landing_page_url":"http://hdl.handle.net/2440/16741","pdf_url":null,"source":{"id":"https://openalex.org/S4306401835","display_name":"Adelaide Research & Scholarship (AR&S) (University of Adelaide)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I5681781","host_organization_name":"The University of Adelaide","host_organization_lineage":["https://openalex.org/I5681781"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"https://doi.org/10.1061/(asce)0733-9496(2005)131:4(316)","raw_type":"Journal article"},{"id":"pmh:oai:lup.lub.lu.se:a7493a78-38e3-4299-a414-c275f7f1371f","doi":null,"is_oa":false,"landing_page_url":"https://lup.lub.lu.se/record/233782","pdf_url":null,"source":{"id":"https://openalex.org/S4306400536","display_name":"Lund University Publications (Lund University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I187531555","host_organization_name":"Lund University","host_organization_lineage":["https://openalex.org/I187531555"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"ISSN: 0733-9496","raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.7207000255584717}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320320936","display_name":"Royal Swedish Academy of Sciences","ror":"https://ror.org/00j62qv07"},{"id":"https://openalex.org/F4320334704","display_name":"Australian Research Council","ror":"https://ror.org/05mmh0f86"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W59826130","https://openalex.org/W1567265551","https://openalex.org/W1868081366","https://openalex.org/W1969780039","https://openalex.org/W1972118609","https://openalex.org/W2005154074","https://openalex.org/W2010922160","https://openalex.org/W2023524830","https://openalex.org/W2048979357","https://openalex.org/W2051903196","https://openalex.org/W2056705165","https://openalex.org/W2058862986","https://openalex.org/W2070468178","https://openalex.org/W2090258153","https://openalex.org/W2119356525","https://openalex.org/W2546609409"],"related_works":["https://openalex.org/W1868081366","https://openalex.org/W1683397072","https://openalex.org/W2129185340","https://openalex.org/W1811445279","https://openalex.org/W3130100939","https://openalex.org/W7033601057","https://openalex.org/W1754695804","https://openalex.org/W6981010088","https://openalex.org/W2155791057","https://openalex.org/W1565224653"],"abstract_inverted_index":{"Sudden":[0],"pipe":[1,71],"breaks":[2,15,42,66,169,199],"occur":[3],"in":[4,67,80,155,200],"water":[5],"transmission":[6],"pipelines":[7],"and":[8,29,34,51,64,88,111,173,188,191,196],"distribution":[9],"mains.":[10],"The":[11,36,125,138,159,176],"consequences":[12],"of":[13,21,27,108,122,127,134,162,170],"these":[14],"can":[16,43],"be":[17,44],"very":[18],"expensive":[19],"because":[20],"the":[22,25,40,48,85,92,96,104,106,109,117,120,123,128,135,156],"service":[23],"interruption,":[24],"cost":[26],"repair,":[28],"damage":[30],"to":[31,150,167],"surrounding":[32],"property":[33],"infrastructure.":[35],"costs":[37],"associated":[38],"with":[39],"pipeline":[41,93],"reduced":[45],"by":[46,116,182],"minimizing":[47],"break":[49,72,86,118,136],"detection":[50],"location":[52,102,121],"time.":[53],"This":[54],"paper":[55],"presents":[56],"a":[57,74,143],"new":[58],"continuous":[59,139,177],"monitoring":[60,140,178],"approach":[61],"for":[62,194],"detecting":[63,195],"locating":[65,197],"pipelines.":[68,202],"A":[69],"sudden":[70,198],"creates":[73],"negative":[75],"pressure":[76,97,157],"wave":[77,130],"that":[78],"travels":[79],"both":[81,186],"directions":[82],"away":[83],"from":[84,185],"point":[87],"is":[89,165,180],"reflected":[90,112],"at":[91,100],"boundaries.":[94],"Using":[95],"data":[98],"measured":[99],"one":[101],"along":[103],"pipeline,":[105],"timing":[107],"initial":[110],"transient":[113,129],"waves":[114],"induced":[115],"determines":[119],"break.":[124],"magnitude":[126],"provides":[131],"an":[132],"estimate":[133],"size.":[137],"technique":[141,179],"uses":[142],"modified":[144],"two-sided":[145],"cumulative":[146],"sum":[147],"(CUSUM)":[148],"algorithm":[149],"detect":[151,168],"abrupt":[152],"break-induced":[153],"changes":[154],"data.":[158],"adaptive":[160],"tuning":[161],"CUSUM":[163],"parameters":[164],"implemented":[166],"differing":[171],"sizes":[172],"opening":[174],"times.":[175],"verified":[181],"using":[183],"results":[184],"laboratory":[187],"field":[189],"experiments":[190],"shows":[192],"potential":[193],"real":[201]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2145114963","counts_by_year":[{"year":2026,"cited_by_count":3},{"year":2025,"cited_by_count":5},{"year":2024,"cited_by_count":7},{"year":2023,"cited_by_count":6},{"year":2022,"cited_by_count":10},{"year":2021,"cited_by_count":9},{"year":2020,"cited_by_count":10},{"year":2019,"cited_by_count":11},{"year":2018,"cited_by_count":5},{"year":2017,"cited_by_count":5},{"year":2016,"cited_by_count":8},{"year":2015,"cited_by_count":5},{"year":2014,"cited_by_count":8},{"year":2013,"cited_by_count":8},{"year":2012,"cited_by_count":12}],"updated_date":"2026-11-25T09:40:18.809321","created_date":"2016-06-24T00:00:00"}