{"id":"https://openalex.org/W2144722285","doi":"https://doi.org/10.1109/86.296345","title":"Slip information provided by nerve cuff signals: application in closed-loop control of functional electrical stimulation","display_name":"Slip information provided by nerve cuff signals: application in closed-loop control of functional electrical stimulation","alternate_titles":[],"publication_year":1994,"publication_date":"1994-03-01","ids":{"openalex":"https://openalex.org/W2144722285","doi":"https://doi.org/10.1109/86.296345","mag":"2144722285"},"language":"en","primary_location":{"id":"doi:10.1109/86.296345","doi":"https://doi.org/10.1109/86.296345","is_oa":false,"landing_page_url":"https://doi.org/10.1109/86.296345","pdf_url":null,"source":{"id":"https://openalex.org/S101490220","display_name":"IEEE Transactions on Rehabilitation Engineering","issn_l":"1063-6528","issn":["1063-6528","1558-0024"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Rehabilitation Engineering","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2144722285"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5108364360","display_name":"M.K. Haugland","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I891191580","display_name":"Aalborg University","ror":"https://ror.org/04m5j1k67","country_code":"DK","type":"education","lineage":["https://openalex.org/I891191580"]}],"countries":["DK"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"M.K. Haugland","raw_affiliation_strings":["Department of Medical Informatics and Image Analysis, Institute of Electronic Systems, University of Aalborg, Aalborg, Denmark"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Medical Informatics and Image Analysis, Institute of Electronic Systems, University of Aalborg, Aalborg, Denmark","institution_ids":["https://openalex.org/I891191580"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5006263355","display_name":"J. A. Hoffer","orcid":"https://orcid.org/0000-0003-2259-1908","observed_orcids":["https://orcid.org/0000-0003-2259-1908"]},"institutions":[{"id":"https://openalex.org/I18014758","display_name":"Simon Fraser University","ror":"https://ror.org/0213rcc28","country_code":"CA","type":"education","lineage":["https://openalex.org/I18014758"]}],"countries":["CA"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"J.A. Hoffer","raw_affiliation_strings":["School of Kinesiology, Faculty of Applied Sciences, Simon Fraser University, Burnaby, BC, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Kinesiology, Faculty of Applied Sciences, Simon Fraser University, Burnaby, BC, Canada","institution_ids":["https://openalex.org/I18014758"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.2484,"has_fulltext":false,"cited_by_count":89,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.77183707,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":98},"biblio":{"volume":"2","issue":"1","first_page":"29","last_page":"36"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11601","display_name":"Neuroscience and Neural Engineering","score":0.38960000872612,"subfield":{"id":"https://openalex.org/subfields/2804","display_name":"Cellular and Molecular Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},"topics":[{"id":"https://openalex.org/T11601","display_name":"Neuroscience and Neural Engineering","score":0.38960000872612,"subfield":{"id":"https://openalex.org/subfields/2804","display_name":"Cellular and Molecular Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},{"id":"https://openalex.org/T10784","display_name":"Muscle activation and electromyography studies","score":0.35499998927116394,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10510","display_name":"Stroke Rehabilitation and Recovery","score":0.15330000221729279,"subfield":{"id":"https://openalex.org/subfields/2742","display_name":"Rehabilitation"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/functional-electrical-stimulation","display_name":"functional electrical stimulation","score":0.8769999742507935},{"id":"https://openalex.org/keywords/slip-detection","display_name":"slip detection","score":0.6140000224113464},{"id":"https://openalex.org/keywords/nerve-cuff-electrodes","display_name":"cuff electrodes","score":0.6389999985694885},{"id":"https://openalex.org/keywords/tibial-nerve","display_name":"tibial nerve","score":0.824999988079071},{"id":"https://openalex.org/keywords/electroneurography","display_name":"electroneurography","score":0.8270000219345093},{"id":"https://openalex.org/keywords/mechanoreceptors","display_name":"mechanoreceptors","score":0.7960000038146973},{"id":"https://openalex.org/keywords/feedback-control","display_name":"feedback control","score":0.8100000023841858},{"id":"https://openalex.org/keywords/event-triggered-control","display_name":"event-triggered control","score":0.7200000286102295},{"id":"https://openalex.org/keywords/muscle-fatigue","display_name":"muscle fatigue","score":0.4860000014305115}],"concepts":[{"id":"https://openalex.org/C2777766275","wikidata":"https://www.wikidata.org/wiki/Q1327643","display_name":"Functional electrical stimulation","level":3,"score":0.7097345590591431},{"id":"https://openalex.org/C24998067","wikidata":"https://www.wikidata.org/wiki/Q4114622","display_name":"Stimulation","level":2,"score":0.5538432598114014},{"id":"https://openalex.org/C2778640784","wikidata":"https://www.wikidata.org/wiki/Q168002","display_name":"Ankle","level":2,"score":0.5331900119781494},{"id":"https://openalex.org/C2780017030","wikidata":"https://www.wikidata.org/wiki/Q368366","display_name":"Cuff","level":2,"score":0.5158659815788269},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.42890697717666626},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.3430534601211548},{"id":"https://openalex.org/C105702510","wikidata":"https://www.wikidata.org/wiki/Q514","display_name":"Anatomy","level":1,"score":0.3177834451198578},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.28360462188720703},{"id":"https://openalex.org/C169760540","wikidata":"https://www.wikidata.org/wiki/Q207011","display_name":"Neuroscience","level":1,"score":0.23436284065246582},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.15018829703330994},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.09424445033073425}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/86.296345","doi":"https://doi.org/10.1109/86.296345","is_oa":false,"landing_page_url":"https://doi.org/10.1109/86.296345","pdf_url":null,"source":{"id":"https://openalex.org/S101490220","display_name":"IEEE Transactions on Rehabilitation Engineering","issn_l":"1063-6528","issn":["1063-6528","1558-0024"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Rehabilitation Engineering","raw_type":"journal-article"},{"id":"pmh:oai:pure.atira.dk:publications/403b6e90-832c-11de-9240-000ea68e967b","doi":null,"is_oa":false,"landing_page_url":"https://vbn.aau.dk/da/publications/403b6e90-832c-11de-9240-000ea68e967b","pdf_url":null,"source":{"id":"https://openalex.org/S4306401731","display_name":"VBN Forskningsportal (Aalborg Universitet)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I891191580","host_organization_name":"Aalborg University","host_organization_lineage":["https://openalex.org/I891191580"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Haugland, M K & Hoffer, A 1994, 'Slip information provided by nerve cuff signals : application in closed-loop control of functional electrical stimulation', IEEE transactions on rehabilitation engineering, vol. 2, no. 1, pp. 29-36. https://doi.org/10.1109/86.296345","raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.766700029373169,"display_name":"Good health and well-being","id":"https://metadata.un.org/sdg/3"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":24,"referenced_works":["https://openalex.org/W1595629881","https://openalex.org/W1774657277","https://openalex.org/W1967848970","https://openalex.org/W1968181716","https://openalex.org/W1979363806","https://openalex.org/W2029384059","https://openalex.org/W2032427945","https://openalex.org/W2032670029","https://openalex.org/W2037831228","https://openalex.org/W2045222441","https://openalex.org/W2045484898","https://openalex.org/W2061696957","https://openalex.org/W2065584726","https://openalex.org/W2104353092","https://openalex.org/W2122845088","https://openalex.org/W2140196459","https://openalex.org/W2181970214","https://openalex.org/W2314128867","https://openalex.org/W2341122572","https://openalex.org/W2442713783","https://openalex.org/W2481660679","https://openalex.org/W2539388841","https://openalex.org/W2548487437","https://openalex.org/W2745479848"],"related_works":["https://openalex.org/W2539388841","https://openalex.org/W2130603866","https://openalex.org/W2112093452","https://openalex.org/W2011623748","https://openalex.org/W2167690665","https://openalex.org/W2032670029","https://openalex.org/W2147548785","https://openalex.org/W2542050179","https://openalex.org/W2122845088","https://openalex.org/W63869231"],"abstract_inverted_index":{"A":[0],"model":[1],"of":[2,130],"a":[3,50],"paralyzed":[4,134],"hand":[5],"gripping":[6,95],"and":[7,32,70,106,122],"lifting":[8],"an":[9,34,78,93],"object":[10,69],"was":[11,47,75,97],"developed":[12],"using":[13],"anaesthetized":[14],"cats.":[15],"Functional":[16],"neuromuscular":[17],"stimulation":[18],"(FNS)":[19],"applied":[20],"to":[21,29,86,119,125],"the":[22,27,45,55,62,68,71,83,107],"ankle":[23],"plantarflexor":[24],"muscles":[25],"caused":[26],"footpad":[28,46],"press":[30],"against":[31],"grip":[33,132],"object.":[35],"Electroneurographic":[36],"activity":[37,39],"(ENG)":[38],"generated":[40],"by":[41],"skin":[42],"mechanoreceptors":[43],"in":[44,61,77,133],"recorded":[48],"with":[49],"cuff":[51],"electrode":[52],"implanted":[53],"on":[54],"tibial":[56],"nerve.":[57],"Sharp":[58],"bursts":[59],"evident":[60],"ENG":[63],"signaled":[64],"any":[65],"slips":[66],"between":[67],"skin.":[72],"This":[73,115],"information":[74],"used":[76],"event-driven":[79],"controller":[80],"that":[81,99],"allowed":[82],"FNS":[84],"system":[85],"compensate":[87],"for":[88,102,128],"slips.":[89],"In":[90],"this":[91],"way":[92],"\"artificial":[94],"reflex\"":[96],"implemented":[98],"compensated":[100],"automatically":[101],"internal":[103],"changes":[104],"(fatigue)":[105],"external":[108],"perturbations":[109],"(increased":[110],"load,":[111],"changed":[112],"frictional":[113],"coefficient).":[114],"control":[116],"scheme":[117],"proved":[118],"be":[120,126],"robust":[121],"is":[123],"proposed":[124],"applicable":[127],"restoration":[129],"precision":[131],"humans.>":[135]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2144722285","counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2024,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2018,"cited_by_count":2},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":2},{"year":2014,"cited_by_count":1},{"year":2013,"cited_by_count":6},{"year":2012,"cited_by_count":1}],"updated_date":"2026-11-21T10:27:49.728292","created_date":"2016-06-24T00:00:00"}
