{"id":"https://openalex.org/W2139787881","doi":"https://doi.org/10.1016/j.jconhyd.2005.03.003","title":"Numerical simulations of radon as an in situ partitioning tracer for quantifying NAPL contamination using push\u2013pull tests","display_name":"Numerical simulations of radon as an in situ partitioning tracer for quantifying NAPL contamination using push\u2013pull tests","publication_year":2005,"publication_date":"2005-06-01","ids":{"openalex":"https://openalex.org/W2139787881","doi":"https://doi.org/10.1016/j.jconhyd.2005.03.003","mag":"2139787881","pmid":"https://pubmed.ncbi.nlm.nih.gov/15949608"},"language":"en","primary_location":{"id":"doi:10.1016/j.jconhyd.2005.03.003","doi":"https://doi.org/10.1016/j.jconhyd.2005.03.003","is_oa":false,"landing_page_url":"https://doi.org/10.1016/j.jconhyd.2005.03.003","pdf_url":null,"source":{"id":"https://openalex.org/S20728117","display_name":"Journal of Contaminant Hydrology","issn_l":"0169-7722","issn":["0169-7722","1873-6009"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-d","jufo-1","medline","norway-1","poland-100","russia-white-list-1"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Contaminant Hydrology","raw_type":"journal-article"},"volume":null,"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"B.M. Davis","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"B.M. Davis","raw_affiliation_strings":["ChevronTexaco Energy Technology Co., PO Box 1627, 100 Chevron Way, Richmond, CA 94802, USA. bmda@chevrontexaco.com","ChevronTexaco Energy Technology Co., PO Box 1627, 100 Chevron Way, Richmond, CA 94802, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"ChevronTexaco Energy Technology Co., PO Box 1627, 100 Chevron Way, Richmond, CA 94802, USA. bmda@chevrontexaco.com","institution_ids":[]},{"raw_affiliation_string":"ChevronTexaco Energy Technology Co., PO Box 1627, 100 Chevron Way, Richmond, CA 94802, USA","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5079125454","display_name":"Jonathan David Istok","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I131249849","display_name":"Oregon State University","ror":"https://ror.org/00ysfqy60","country_code":"US","type":"education","lineage":["https://openalex.org/I131249849"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"J.D. Istok","raw_affiliation_strings":["Department of Civil, Construction and Environmental Engineering, Oregon State University, Corvallis, OR 97331, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Civil, Construction and Environmental Engineering, Oregon State University, Corvallis, OR 97331, USA","institution_ids":["https://openalex.org/I131249849"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5058723243","display_name":"Lewis Semprini","orcid":"https://orcid.org/0000-0002-9174-4464","observed_orcids":["https://orcid.org/0000-0002-9174-4464"]},"institutions":[{"id":"https://openalex.org/I131249849","display_name":"Oregon State University","ror":"https://ror.org/00ysfqy60","country_code":"US","type":"education","lineage":["https://openalex.org/I131249849"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"L. Semprini","raw_affiliation_strings":["Department of Civil, Construction and Environmental Engineering, Oregon State University, Corvallis, OR 97331, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Civil, Construction and Environmental Engineering, Oregon State University, Corvallis, OR 97331, USA","institution_ids":["https://openalex.org/I131249849"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":3640,"currency":"USD","value_usd":3640},"apc_paid":null,"fwci":2.5705,"has_fulltext":false,"cited_by_count":31,"citation_normalized_percentile":{"value":0.88532327,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":97},"biblio":{"volume":"78","issue":"1-2","first_page":"87","last_page":"103"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10894","display_name":"Groundwater flow and contamination studies","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2305","display_name":"Environmental Engineering"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10894","display_name":"Groundwater flow and contamination studies","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2305","display_name":"Environmental Engineering"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10398","display_name":"Groundwater and Isotope Geochemistry","score":0.0010999999940395355,"subfield":{"id":"https://openalex.org/subfields/1906","display_name":"Geochemistry and Petrology"},"field":{"id":"https://openalex.org/fields/19","display_name":"Earth and Planetary Sciences"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10716","display_name":"Soil and Unsaturated Flow","score":0.00019999999494757503,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/radon-222","display_name":"radon-222","score":0.9800000190734863},{"id":"https://openalex.org/keywords/push-pull-tests","display_name":"push-pull tests","score":0.8679999709129333},{"id":"https://openalex.org/keywords/partitioning-tracers","display_name":"partitioning tracers","score":0.7889999747276306},{"id":"https://openalex.org/keywords/napl-contamination","display_name":"NAPL contamination","score":0.828000009059906},{"id":"https://openalex.org/keywords/dense-nonaqueous-phase-liquids","display_name":"dense non-aqueous phase liquids","score":0.9160000085830688},{"id":"https://openalex.org/keywords/light-non-aqueous-phase-liquids","display_name":"light non-aqueous phase liquids","score":0.9750000238418579},{"id":"https://openalex.org/keywords/trichloroethylene","display_name":"trichloroethylene","score":0.9110000133514404},{"id":"https://openalex.org/keywords/aquifer-heterogeneity","display_name":"aquifer heterogeneity","score":0.8379999995231628},{"id":"https://openalex.org/keywords/remediation-monitoring","display_name":"remediation monitoring","score":0.6700000166893005},{"id":"https://openalex.org/keywords/groundwater-contamination","display_name":"groundwater contamination","score":0.3529999852180481}],"concepts":[{"id":"https://openalex.org/C545943180","wikidata":"https://www.wikidata.org/wiki/Q1133","display_name":"Radon","level":2,"score":0.8964858055114746},{"id":"https://openalex.org/C2778863792","wikidata":"https://www.wikidata.org/wiki/Q16909918","display_name":"TRACER","level":2,"score":0.8448405265808105},{"id":"https://openalex.org/C112570922","wikidata":"https://www.wikidata.org/wiki/Q60528603","display_name":"Contamination","level":2,"score":0.6600228548049927},{"id":"https://openalex.org/C2776300020","wikidata":"https://www.wikidata.org/wiki/Q422423","display_name":"Bromide","level":2,"score":0.5653887391090393},{"id":"https://openalex.org/C75622301","wikidata":"https://www.wikidata.org/wiki/Q208791","display_name":"Aquifer","level":3,"score":0.52101731300354},{"id":"https://openalex.org/C192552737","wikidata":"https://www.wikidata.org/wiki/Q898797","display_name":"Partition coefficient","level":2,"score":0.4517407715320587},{"id":"https://openalex.org/C159390177","wikidata":"https://www.wikidata.org/wiki/Q9161265","display_name":"Soil science","level":1,"score":0.4440135657787323},{"id":"https://openalex.org/C177562468","wikidata":"https://www.wikidata.org/wiki/Q182893","display_name":"Dispersion (optics)","level":2,"score":0.4390433132648468},{"id":"https://openalex.org/C9930424","wikidata":"https://www.wikidata.org/wiki/Q7426587","display_name":"Saturation (graph theory)","level":2,"score":0.418915331363678},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.41045069694519043},{"id":"https://openalex.org/C76177295","wikidata":"https://www.wikidata.org/wiki/Q161598","display_name":"Groundwater","level":2,"score":0.41021212935447693},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.3876599967479706},{"id":"https://openalex.org/C199289684","wikidata":"https://www.wikidata.org/wiki/Q83353","display_name":"Mineralogy","level":1,"score":0.3441603183746338},{"id":"https://openalex.org/C76886044","wikidata":"https://www.wikidata.org/wiki/Q2883300","display_name":"Hydrology (agriculture)","level":2,"score":0.32805120944976807},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.27922964096069336},{"id":"https://openalex.org/C187320778","wikidata":"https://www.wikidata.org/wiki/Q1349130","display_name":"Geotechnical engineering","level":1,"score":0.15412232279777527},{"id":"https://openalex.org/C43617362","wikidata":"https://www.wikidata.org/wiki/Q170050","display_name":"Chromatography","level":1,"score":0.10780343413352966},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.09201797842979431},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0683521032333374},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.0},{"id":"https://openalex.org/C178790620","wikidata":"https://www.wikidata.org/wiki/Q11351","display_name":"Organic chemistry","level":1,"score":0.0},{"id":"https://openalex.org/C114614502","wikidata":"https://www.wikidata.org/wiki/Q76592","display_name":"Combinatorics","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C18903297","wikidata":"https://www.wikidata.org/wiki/Q7150","display_name":"Ecology","level":1,"score":0.0},{"id":"https://openalex.org/C185544564","wikidata":"https://www.wikidata.org/wiki/Q81197","display_name":"Nuclear physics","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0}],"mesh":[{"descriptor_ui":"D003198","descriptor_name":"Computer Simulation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004784","descriptor_name":"Environmental Monitoring","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D011849","descriptor_name":"Radioactive Tracers","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011886","descriptor_name":"Radon","qualifier_ui":"Q000032","qualifier_name":"analysis","is_major_topic":true},{"descriptor_ui":"D014241","descriptor_name":"Trichloroethylene","qualifier_ui":"Q000032","qualifier_name":"analysis","is_major_topic":false},{"descriptor_ui":"D014874","descriptor_name":"Water Pollutants, Chemical","qualifier_ui":"Q000032","qualifier_name":"analysis","is_major_topic":true}],"locations_count":2,"locations":[{"id":"doi:10.1016/j.jconhyd.2005.03.003","doi":"https://doi.org/10.1016/j.jconhyd.2005.03.003","is_oa":false,"landing_page_url":"https://doi.org/10.1016/j.jconhyd.2005.03.003","pdf_url":null,"source":{"id":"https://openalex.org/S20728117","display_name":"Journal of Contaminant Hydrology","issn_l":"0169-7722","issn":["0169-7722","1873-6009"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-d","jufo-1","medline","norway-1","poland-100","russia-white-list-1"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Contaminant Hydrology","raw_type":"journal-article"},{"id":"pmid:15949608","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/15949608","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of contaminant hydrology","raw_type":"Journal Article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.53329998254776,"id":"https://metadata.un.org/sdg/6","display_name":"Clean water and sanitation"}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320306078","display_name":"U.S. Department of Defense","ror":"https://ror.org/0447fe631"},{"id":"https://openalex.org/F4320306084","display_name":"U.S. Department of Energy","ror":"https://ror.org/01bj3aw27"},{"id":"https://openalex.org/F4320333589","display_name":"Environmental Security Technology Certification Program","ror":null}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":17,"referenced_works":["https://openalex.org/W647677712","https://openalex.org/W1512286896","https://openalex.org/W1859943179","https://openalex.org/W1993906112","https://openalex.org/W1995812185","https://openalex.org/W1997790015","https://openalex.org/W2000121233","https://openalex.org/W2011110428","https://openalex.org/W2011974430","https://openalex.org/W2012539600","https://openalex.org/W2031370347","https://openalex.org/W2057947835","https://openalex.org/W2070644555","https://openalex.org/W2076556071","https://openalex.org/W2102081525","https://openalex.org/W2238850167","https://openalex.org/W2477341225"],"related_works":["https://openalex.org/W2076556071","https://openalex.org/W2011110428","https://openalex.org/W1582322529","https://openalex.org/W2030295205","https://openalex.org/W1512286896","https://openalex.org/W2011974430","https://openalex.org/W2003045035","https://openalex.org/W1513486228","https://openalex.org/W300153603","https://openalex.org/W876497791"],"abstract_inverted_index":null,"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":3},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":2},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":2},{"year":2013,"cited_by_count":2},{"year":2012,"cited_by_count":3}],"updated_date":"2026-10-31T12:09:11.096373","created_date":"2016-06-24T00:00:00"}
