{"id":"https://openalex.org/W2139759405","doi":"https://doi.org/10.1109/ptc.2011.6019192","title":"Design, operation and availability analysis of a multi-terminal HVDC grid - A case study of a possible Offshore Grid in the Norwegian Sea","display_name":"Design, operation and availability analysis of a multi-terminal HVDC grid - A case study of a possible Offshore Grid in the Norwegian Sea","alternate_titles":[],"publication_year":2011,"publication_date":"2011-06-01","ids":{"openalex":"https://openalex.org/W2139759405","doi":"https://doi.org/10.1109/ptc.2011.6019192","mag":"2139759405"},"language":"en","primary_location":{"id":"doi:10.1109/ptc.2011.6019192","doi":"https://doi.org/10.1109/ptc.2011.6019192","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ptc.2011.6019192","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 IEEE Trondheim PowerTech","raw_type":"proceedings-article"},"parent_works":[],"lineage":["https://openalex.org/W2139759405"],"child_works_count":0,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5088126559","display_name":"\u00d8yvind August Rui","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210155328","display_name":"Statnett (Norway)","ror":"https://ror.org/05232hy51","country_code":"NO","type":"company","lineage":["https://openalex.org/I4210155328"]}],"countries":["NO"],"is_corresponding":false,"raw_author_name":"O. Rui","raw_affiliation_strings":["Statnett SF, Norway"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Statnett SF, Norway","institution_ids":["https://openalex.org/I4210155328"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5089319842","display_name":"Carl Ohlen","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210155328","display_name":"Statnett (Norway)","ror":"https://ror.org/05232hy51","country_code":"NO","type":"company","lineage":["https://openalex.org/I4210155328"]}],"countries":["NO"],"is_corresponding":false,"raw_author_name":"C. Ohlen","raw_affiliation_strings":["Statnett SF","STRI., Norway"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Statnett SF","institution_ids":["https://openalex.org/I4210155328"]},{"raw_affiliation_string":"STRI., Norway","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5013756047","display_name":"Johan Solvik","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I188703460","display_name":"DNV (Norway)","ror":"https://ror.org/04c235406","country_code":"NO","type":"company","lineage":["https://openalex.org/I188703460"]}],"countries":["NO"],"is_corresponding":false,"raw_author_name":"J. Solvik","raw_affiliation_strings":["STRI","Det Norske Veritas, Norway"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STRI","institution_ids":[]},{"raw_affiliation_string":"Det Norske Veritas, Norway","institution_ids":["https://openalex.org/I188703460"]}]},{"author_position":"middle","author":{"id":null,"display_name":"J. Thon","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I188703460","display_name":"DNV (Norway)","ror":"https://ror.org/04c235406","country_code":"NO","type":"company","lineage":["https://openalex.org/I188703460"]},{"id":"https://openalex.org/I4210155328","display_name":"Statnett (Norway)","ror":"https://ror.org/05232hy51","country_code":"NO","type":"company","lineage":["https://openalex.org/I4210155328"]}],"countries":["NO"],"is_corresponding":false,"raw_author_name":"J. Thon","raw_affiliation_strings":["Det Norske Veritas","Statnett SF, Norway"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Det Norske Veritas","institution_ids":["https://openalex.org/I188703460"]},{"raw_affiliation_string":"Statnett SF, Norway","institution_ids":["https://openalex.org/I4210155328"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5026327364","display_name":"K. Karijord","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210155328","display_name":"Statnett (Norway)","ror":"https://ror.org/05232hy51","country_code":"NO","type":"company","lineage":["https://openalex.org/I4210155328"]}],"countries":["NO"],"is_corresponding":false,"raw_author_name":"K. Karijord","raw_affiliation_strings":["Statnett SF","Statnett SF, Norway"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Statnett SF","institution_ids":["https://openalex.org/I4210155328"]},{"raw_affiliation_string":"Statnett SF, Norway","institution_ids":["https://openalex.org/I4210155328"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5089582364","display_name":"Terje Gjengedal","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I204778367","display_name":"Norwegian University of Science and Technology","ror":"https://ror.org/05xg72x27","country_code":"NO","type":"education","lineage":["https://openalex.org/I204778367"]},{"id":"https://openalex.org/I4210155328","display_name":"Statnett (Norway)","ror":"https://ror.org/05232hy51","country_code":"NO","type":"company","lineage":["https://openalex.org/I4210155328"]}],"countries":["NO"],"is_corresponding":false,"raw_author_name":"T. Gjengedal","raw_affiliation_strings":["Statnett SF, NTNU","Statnett SF and NTNU, Norway"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Statnett SF, NTNU","institution_ids":["https://openalex.org/I204778367"]},{"raw_affiliation_string":"Statnett SF and NTNU, Norway","institution_ids":["https://openalex.org/I204778367","https://openalex.org/I4210155328"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":2.9656,"has_fulltext":false,"cited_by_count":26,"citation_normalized_percentile":{"value":0.90797831,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":87,"max":98},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"7"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11185","display_name":"Integrated Energy Systems Optimization","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/multiterminal-hvdc","display_name":"multi-terminal HVDC","score":0.9330000281333923},{"id":"https://openalex.org/keywords/subsea-cables","display_name":"subsea cables","score":0.7689999938011169},{"id":"https://openalex.org/keywords/offshore-grid","display_name":"offshore grid","score":0.8650000095367432},{"id":"https://openalex.org/keywords/offshore-wind-energy","display_name":"offshore wind energy","score":0.9309999942779541},{"id":"https://openalex.org/keywords/offshore-oil-and-gas","display_name":"offshore oil and gas","score":0.7919999957084656},{"id":"https://openalex.org/keywords/power-system-reliability","display_name":"power system reliability","score":0.703000009059906},{"id":"https://openalex.org/keywords/fault-clearing","display_name":"fault clearance","score":0.6850000023841858},{"id":"https://openalex.org/keywords/hvdc-control","display_name":"HVDC control","score":0.8500000238418579},{"id":"https://openalex.org/keywords/grid-availability","display_name":"grid availability","score":0.550000011920929},{"id":"https://openalex.org/keywords/norwegian-sea","display_name":"Norwegian Sea","score":0.6330000162124634}],"concepts":[{"id":"https://openalex.org/C2777737062","wikidata":"https://www.wikidata.org/wiki/Q14898686","display_name":"Subsea","level":2,"score":0.7685741186141968},{"id":"https://openalex.org/C8735168","wikidata":"https://www.wikidata.org/wiki/Q61637704","display_name":"Offshore wind power","level":3,"score":0.7582131624221802},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.6766701936721802},{"id":"https://openalex.org/C162284963","wikidata":"https://www.wikidata.org/wiki/Q17106102","display_name":"Submarine pipeline","level":2,"score":0.5998164415359497},{"id":"https://openalex.org/C199104240","wikidata":"https://www.wikidata.org/wiki/Q118291","display_name":"Marine engineering","level":1,"score":0.5907868146896362},{"id":"https://openalex.org/C2779664074","wikidata":"https://www.wikidata.org/wiki/Q3518405","display_name":"Terminal (telecommunication)","level":2,"score":0.5779827833175659},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.48442700505256653},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.45950740575790405},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.44889241456985474},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3659307658672333},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.35865265130996704},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3262704014778137},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.314736545085907},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.21251755952835083},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.1366463005542755},{"id":"https://openalex.org/C187320778","wikidata":"https://www.wikidata.org/wiki/Q1349130","display_name":"Geotechnical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C13280743","wikidata":"https://www.wikidata.org/wiki/Q131089","display_name":"Geodesy","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ptc.2011.6019192","doi":"https://doi.org/10.1109/ptc.2011.6019192","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ptc.2011.6019192","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 IEEE Trondheim PowerTech","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":1.0},{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.8970999717712402},{"id":"https://metadata.un.org/sdg/13","display_name":"Climate action","score":0.4399999976158142}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W1562065634","https://openalex.org/W2005963716","https://openalex.org/W2103606537","https://openalex.org/W6634004748"],"related_works":["https://openalex.org/W2181414411","https://openalex.org/W2107435583","https://openalex.org/W2801870053","https://openalex.org/W269896242","https://openalex.org/W2558478312","https://openalex.org/W1596052872","https://openalex.org/W2606257180","https://openalex.org/W7219775585","https://openalex.org/W3146295208","https://openalex.org/W3152364547"],"abstract_inverted_index":{"Multi-terminal":[0],"HVDC":[1,63],"subsea":[2],"cable":[3],"grids":[4,33],"have":[5,34],"the":[6,17,28,52],"ability":[7],"to":[8,42],"integrate":[9],"offshore":[10,83],"wind":[11],"power":[12],"and":[13,71,81,103],"petroleum":[14],"installations":[15],"with":[16,27,77],"main":[18],"land,":[19],"as":[20,22,56],"well":[21],"transferring":[23],"energy":[24],"in":[25,48,87],"parallel":[26],"onshore":[29],"AC":[30],"grid.":[31],"Such":[32],"presumably":[35],"lower":[36],"investment":[37],"costs":[38],"than":[39],"radial":[40],"cables":[41],"each":[43],"installation.":[44],"It":[45],"is":[46,54,85,92],"shown":[47],"this":[49,88],"paper":[50],"that":[51],"reliability":[53],"higher":[55],"well.":[57],"The":[58,90],"operation":[59],"of":[60,95],"a":[61,93],"multi-terminal":[62],"grid":[64],"calls":[65],"for":[66,69],"new":[67],"methods":[68],"control":[70],"fault":[72],"clearing.":[73],"A":[74],"case":[75],"study":[76],"two":[78],"land":[79],"terminals":[80,84],"three":[82],"presented":[86],"paper.":[89],"work":[91],"part":[94],"Statnett's":[96],"R&D":[97],"project":[98],"\u201cOffshore":[99],"Grid":[100],"-":[101],"design":[102],"operation.\u201d":[104]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2139759405","counts_by_year":[{"year":2024,"cited_by_count":2},{"year":2021,"cited_by_count":1},{"year":2019,"cited_by_count":3},{"year":2018,"cited_by_count":3},{"year":2017,"cited_by_count":2},{"year":2016,"cited_by_count":5},{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":1},{"year":2013,"cited_by_count":3},{"year":2012,"cited_by_count":5}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-06-24T00:00:00"}
