{"id":"https://openalex.org/W2139741069","doi":"https://doi.org/10.1002/we.1852","title":"Model-based fault detection for generator cooling system in wind turbines using SCADA data","display_name":"Model-based fault detection for generator cooling system in wind turbines using SCADA data","alternate_titles":[],"publication_year":2015,"publication_date":"2015-04-17","ids":{"openalex":"https://openalex.org/W2139741069","doi":"https://doi.org/10.1002/we.1852","mag":"2139741069"},"language":"en","primary_location":{"id":"doi:10.1002/we.1852","doi":"https://doi.org/10.1002/we.1852","is_oa":false,"landing_page_url":"https://doi.org/10.1002/we.1852","pdf_url":null,"source":{"id":"https://openalex.org/S79495670","display_name":"Wind Energy","issn_l":"1095-4244","issn":["1095-4244","1099-1824"],"is_oa":false,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-b","jufo-2","norway-2","oarl","poland-140","russia-white-list-2"],"host_organization":"https://openalex.org/P4310320595","host_organization_name":"Wiley","host_organization_lineage":["https://openalex.org/P4310320595"],"host_organization_lineage_names":["Wiley"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Wind Energy","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2139741069"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5043997922","display_name":"Anders Bech Borchersen","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I891191580","display_name":"Aalborg University","ror":"https://ror.org/04m5j1k67","country_code":"DK","type":"education","lineage":["https://openalex.org/I891191580"]}],"countries":["DK"],"is_corresponding":false,"raw_author_name":"A. B. Borchersen","raw_affiliation_strings":["Section of Automation and Control, Department of Electronic Systems, Aalborg University, Fredrik Bajers Vej 7C, 9220 Aalborg, Denmark"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Section of Automation and Control, Department of Electronic Systems, Aalborg University, Fredrik Bajers Vej 7C, 9220 Aalborg, Denmark","institution_ids":["https://openalex.org/I891191580"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5051936919","display_name":"Michel Kinnaert","orcid":"https://orcid.org/0000-0003-3855-3957","observed_orcids":["https://orcid.org/0000-0003-3855-3957"]},"institutions":[{"id":"https://openalex.org/I132053463","display_name":"Universit\u00e9 Libre de Bruxelles","ror":"https://ror.org/01r9htc13","country_code":"BE","type":"education","lineage":["https://openalex.org/I132053463"]}],"countries":["BE"],"is_corresponding":false,"raw_author_name":"M. Kinnaert","raw_affiliation_strings":["Department of Control Engineering and System Analysis; Universit\u00e9 libre de Bruxelles (ULB); CP165/55, 50 Ave. F.D. Roosevelt 1050 Brussels Belgium"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Control Engineering and System Analysis; Universit\u00e9 libre de Bruxelles (ULB); CP165/55, 50 Ave. F.D. Roosevelt 1050 Brussels Belgium","institution_ids":["https://openalex.org/I132053463"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":3730,"currency":"USD","value_usd":3730},"apc_paid":null,"fwci":1.7018,"has_fulltext":false,"cited_by_count":45,"citation_normalized_percentile":{"value":0.84196172,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":99},"biblio":{"volume":"19","issue":"4","first_page":"593","last_page":"606"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9804999828338623,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9804999828338623,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.012600000016391277,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.001500000013038516,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fault-detection","display_name":"fault detection","score":0.7900000214576721},{"id":"https://openalex.org/keywords/wind-turbines","display_name":"wind turbines","score":0.7889999747276306},{"id":"https://openalex.org/keywords/generator-cooling-system","display_name":"generator cooling system","score":0.9829999804496765},{"id":"https://openalex.org/keywords/scada-data","display_name":"SCADA data","score":0.8259999752044678},{"id":"https://openalex.org/keywords/hybrid-model","display_name":"hybrid model","score":0.5350000262260437},{"id":"https://openalex.org/keywords/extended-kalman-filter","display_name":"extended Kalman filter","score":0.9179999828338623},{"id":"https://openalex.org/keywords/parameter-estimation","display_name":"parameter estimation","score":0.9850000143051147},{"id":"https://openalex.org/keywords/statistical-change-detection","display_name":"statistical change detection","score":0.9200000166893005},{"id":"https://openalex.org/keywords/incipient-fault-detection","display_name":"early fault detection","score":0.8700000047683716},{"id":"https://openalex.org/keywords/false-alarms","display_name":"false alarms","score":0.6060000061988831},{"id":"https://openalex.org/keywords/condition-monitoring","display_name":"condition monitoring","score":0.6159999966621399}],"concepts":[{"id":"https://openalex.org/C113863187","wikidata":"https://www.wikidata.org/wiki/Q17498","display_name":"SCADA","level":2,"score":0.8512423038482666},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.7201445698738098},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.546736478805542},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.5355935096740723},{"id":"https://openalex.org/C2780992000","wikidata":"https://www.wikidata.org/wiki/Q17016113","display_name":"Generator (circuit theory)","level":3,"score":0.4819883704185486},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4210798144340515},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4023425877094269},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3422292470932007},{"id":"https://openalex.org/C199104240","wikidata":"https://www.wikidata.org/wiki/Q118291","display_name":"Marine engineering","level":1,"score":0.3371464014053345},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2636738419532776},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.1495766043663025},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.11451175808906555},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.11255457997322083},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.07214701175689697},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1002/we.1852","doi":"https://doi.org/10.1002/we.1852","is_oa":false,"landing_page_url":"https://doi.org/10.1002/we.1852","pdf_url":null,"source":{"id":"https://openalex.org/S79495670","display_name":"Wind Energy","issn_l":"1095-4244","issn":["1095-4244","1099-1824"],"is_oa":false,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-b","jufo-2","norway-2","oarl","poland-140","russia-white-list-2"],"host_organization":"https://openalex.org/P4310320595","host_organization_name":"Wiley","host_organization_lineage":["https://openalex.org/P4310320595"],"host_organization_lineage_names":["Wiley"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Wind Energy","raw_type":"journal-article"},{"id":"pmh:oai:pure.atira.dk:publications/50570c50-8544-42bc-af4e-74e34c6eb027","doi":null,"is_oa":false,"landing_page_url":"http://onlinelibrary.wiley.com/wol1/doi/10.1002/we.1852/full","pdf_url":null,"source":{"id":"https://openalex.org/S4306401731","display_name":"VBN Forskningsportal (Aalborg Universitet)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I891191580","host_organization_name":"Aalborg University","host_organization_lineage":["https://openalex.org/I891191580"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Borchersen, A B & Kinnaert, M 2016, 'Model-based fault detection for generator cooling system in wind turbines using SCADA data', Wind Energy, vol. 19, no. 4, pp. 593\u2013606. https://doi.org/10.1002/we.1852","raw_type":"info:eu-repo/semantics/publishedVersion"},{"id":"pmh:oai:dipot.ulb.ac.be:2013/193195","doi":null,"is_oa":false,"landing_page_url":"https://dipot.ulb.ac.be/dspace/bitstream/2013/193195/3/193195.pdf","pdf_url":"https://dipot.ulb.ac.be/dspace/bitstream/2013/193195/3/193195.pdf","source":{"id":"https://openalex.org/S4306401063","display_name":"D\u00e9p\u00f4t institutionnel de l'Universit\u00e9 libre de Bruxelles (Universit\u00e9 Libre de Bruxelles)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I132053463","host_organization_name":"Universit\u00e9 Libre de Bruxelles","host_organization_lineage":["https://openalex.org/I132053463"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Wind energy","raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8485000133514404,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320309606","display_name":"Vattenfall","ror":"https://ror.org/028v4fg64"},{"id":"https://openalex.org/F4320310481","display_name":"Uddannelses- og Forskningsministeriet","ror":"https://ror.org/03ge1nb22"},{"id":"https://openalex.org/F4320323414","display_name":"Mokslo, Inovaciju ir Technologiju Agentura","ror":"https://ror.org/00reard48"},{"id":"https://openalex.org/F4320334770","display_name":"Danish Agency for Science and Higher Education","ror":"https://ror.org/03ge1nb22"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W1964522863","https://openalex.org/W2009637664","https://openalex.org/W2042641006","https://openalex.org/W2044535354","https://openalex.org/W2044883611","https://openalex.org/W2060512336","https://openalex.org/W2066159588","https://openalex.org/W2085019962","https://openalex.org/W2097138094","https://openalex.org/W2110000683","https://openalex.org/W2127064699","https://openalex.org/W2166834795","https://openalex.org/W2171074980","https://openalex.org/W2396427259","https://openalex.org/W2990212009","https://openalex.org/W6712295462"],"related_works":["https://openalex.org/W3041811889","https://openalex.org/W2128136780","https://openalex.org/W7170031761","https://openalex.org/W3092417622","https://openalex.org/W2012748113","https://openalex.org/W7120206754","https://openalex.org/W7213292774","https://openalex.org/W4413271684","https://openalex.org/W3017305581","https://openalex.org/W2534794885"],"abstract_inverted_index":{"In":[0,122],"this":[1],"work,":[2],"an":[3,38,49,105,137],"early":[4],"fault":[5,129],"detection":[6,53],"system":[7,111],"for":[8,160],"the":[9,26,32,61,66,82,94,109,125,128,134,143,161,168,174,183],"generator":[10,33],"cooling":[11,27,62],"of":[12,25,31,75,89,142,163],"wind":[13],"turbines":[14],"is":[15,104,145,148],"presented":[16],"and":[17,97,116,153],"tested.":[18],"It":[19],"relies":[20],"on":[21,72,150],"a":[22,130],"hybrid":[23],"model":[24,34],"system.":[28,63],"The":[29,42],"parameters":[30,44],"are":[35,45,158],"estimated":[36,43],"by":[37,48,93],"extended":[39],"Kalman":[40],"filter.":[41],"then":[46],"processed":[47],"appropriate":[50],"statistical":[51],"change":[52],"algorithm":[54],"in":[55,60,182],"order":[56],"to":[57,176],"detect":[58],"faults":[59,86],"To":[64],"validate":[65],"method,":[67,96],"it":[68,147],"has":[69],"been":[70],"tested":[71],"3":[73],"years":[74],"historical":[76],"data":[77,154,156],"from":[78],"43":[79],"turbines.":[80,166,184],"During":[81],"testing":[83],"period,":[84],"16":[85],"occurred;":[87],"15":[88,114],"these":[90],"were":[91],"detected":[92],"developed":[95],"one":[98],"false":[99,120],"alarm":[100],"was":[101],"issued.":[102],"This":[103],"improvement":[106],"compared":[107],"with":[108],"current":[110],"that":[112,146,157],"gives":[113],"detections":[115],"more":[117],"than":[118],"10":[119],"alarms.":[121],"some":[123],"cases,":[124],"method":[126,144,169],"detects":[127],"long":[131],"time":[132],"before":[133],"turbine":[135],"reports":[136],"alarm.":[138],"A":[139],"further":[140],"advantage":[141],"based":[149],"supervisory":[151],"control":[152],"acquisition":[155],"available":[159],"operator":[162],"all":[164],"modern":[165],"Thereby,":[167],"can":[170],"be":[171],"implemented":[172],"without":[173],"need":[175],"modify":[177],"or":[178],"install":[179],"additional":[180],"components":[181],"Copyright":[185],"\u00a9":[186],"2015":[187],"John":[188],"Wiley":[189],"&":[190],"Sons,":[191],"Ltd.":[192]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2139741069","counts_by_year":[{"year":2025,"cited_by_count":4},{"year":2024,"cited_by_count":8},{"year":2023,"cited_by_count":10},{"year":2022,"cited_by_count":5},{"year":2021,"cited_by_count":4},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":5},{"year":2018,"cited_by_count":4},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":3}],"updated_date":"2026-11-17T12:49:18.490984","created_date":"2016-06-24T00:00:00"}