{"id":"https://openalex.org/W2139485256","doi":"https://doi.org/10.1109/psamp.2006.285402","title":"Protection of High-Voltage AC Cables","display_name":"Protection of High-Voltage AC Cables","alternate_titles":[],"publication_year":2006,"publication_date":"2006-01-01","ids":{"openalex":"https://openalex.org/W2139485256","doi":"https://doi.org/10.1109/psamp.2006.285402","mag":"2139485256"},"language":"en","primary_location":{"id":"doi:10.1109/psamp.2006.285402","doi":"https://doi.org/10.1109/psamp.2006.285402","is_oa":false,"landing_page_url":"https://doi.org/10.1109/psamp.2006.285402","pdf_url":null,"source":{"id":"https://openalex.org/S4306522916","display_name":"Power Systems Conference","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2006 Power Systems Conference: Advanced Metering, Protection, Control, Communication, and Distributed Resources","raw_type":"proceedings-article"},"parent_works":[],"lineage":["https://openalex.org/W2139485256"],"child_works_count":0,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5036461560","display_name":"Demetrios A. Tziouvaras","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4405273072","display_name":"Schweitzer Engineering Laboratories (United States)","ror":"https://ror.org/057yrm276","country_code":"US","type":"company","lineage":["https://openalex.org/I4405273072"]}],"countries":["US"],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"Demetrios Tziouvaras","raw_affiliation_strings":["Schweitzer Engineering Laboratories, Inc., USA","SCHWEITZER ENGINEERING LABORATORIES, INC"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Schweitzer Engineering Laboratories, Inc., USA","institution_ids":["https://openalex.org/I4405273072"]},{"raw_affiliation_string":"SCHWEITZER ENGINEERING LABORATORIES, INC","institution_ids":["https://openalex.org/I4405273072"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5036461560"],"corresponding_institution_ids":["https://openalex.org/I4405273072"],"apc_list":null,"apc_paid":null,"fwci":1.2188,"has_fulltext":false,"cited_by_count":58,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.72676492,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"316","last_page":"328"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9878000020980835,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9878000020980835,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.00930000003427267,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.0007999999797903001,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/underground-cables","display_name":"underground cables","score":0.8790000081062317},{"id":"https://openalex.org/keywords/cable-sheath-grounding","display_name":"cable sheath grounding","score":0.7889999747276306},{"id":"https://openalex.org/keywords/zero-sequence-impedance","display_name":"zero-sequence impedance","score":0.9610000252723694},{"id":"https://openalex.org/keywords/short-circuit-protection","display_name":"short-circuit protection","score":0.8050000071525574},{"id":"https://openalex.org/keywords/overhead-transmission-lines","display_name":"overhead transmission lines","score":0.7850000262260437}],"concepts":[{"id":"https://openalex.org/C168993435","wikidata":"https://www.wikidata.org/wiki/Q6501125","display_name":"Ground","level":2,"score":0.8347405195236206},{"id":"https://openalex.org/C2779960059","wikidata":"https://www.wikidata.org/wiki/Q7113681","display_name":"Overhead (engineering)","level":2,"score":0.6964976787567139},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.6533567309379578},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.6477105021476746},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.5865970849990845},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5795203447341919},{"id":"https://openalex.org/C137802790","wikidata":"https://www.wikidata.org/wiki/Q5280219","display_name":"Direct-buried cable","level":5,"score":0.5574375987052917},{"id":"https://openalex.org/C91199653","wikidata":"https://www.wikidata.org/wiki/Q20110135","display_name":"All-dielectric self-supporting cable","level":5,"score":0.5402218699455261},{"id":"https://openalex.org/C2775861652","wikidata":"https://www.wikidata.org/wiki/Q110701","display_name":"Overhead line","level":2,"score":0.509732186794281},{"id":"https://openalex.org/C138081364","wikidata":"https://www.wikidata.org/wiki/Q852013","display_name":"Shield","level":2,"score":0.5061189532279968},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.50174880027771},{"id":"https://openalex.org/C33441834","wikidata":"https://www.wikidata.org/wiki/Q693004","display_name":"Transmission line","level":2,"score":0.4943959712982178},{"id":"https://openalex.org/C2777300110","wikidata":"https://www.wikidata.org/wiki/Q1577470","display_name":"High-voltage cable","level":3,"score":0.4736907482147217},{"id":"https://openalex.org/C88182573","wikidata":"https://www.wikidata.org/wiki/Q1139740","display_name":"High voltage","level":3,"score":0.4384484589099884},{"id":"https://openalex.org/C77590175","wikidata":"https://www.wikidata.org/wiki/Q3506009","display_name":"Shielded cable","level":2,"score":0.4190690517425537},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.33209228515625},{"id":"https://openalex.org/C180761244","wikidata":"https://www.wikidata.org/wiki/Q354262","display_name":"Cable harness","level":3,"score":0.25184351205825806},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.13599130511283875},{"id":"https://openalex.org/C110925319","wikidata":"https://www.wikidata.org/wiki/Q12855","display_name":"Cable gland","level":2,"score":0.11651352047920227},{"id":"https://openalex.org/C59399137","wikidata":"https://www.wikidata.org/wiki/Q1327423","display_name":"Cable theory","level":4,"score":0.08810004591941833},{"id":"https://openalex.org/C5900021","wikidata":"https://www.wikidata.org/wiki/Q163082","display_name":"Petrology","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/psamp.2006.285402","doi":"https://doi.org/10.1109/psamp.2006.285402","is_oa":false,"landing_page_url":"https://doi.org/10.1109/psamp.2006.285402","pdf_url":null,"source":{"id":"https://openalex.org/S4306522916","display_name":"Power Systems Conference","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2006 Power Systems Conference: Advanced Metering, Protection, Control, Communication, and Distributed Resources","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":7,"referenced_works":["https://openalex.org/W60347853","https://openalex.org/W1909812498","https://openalex.org/W1974077596","https://openalex.org/W2162423569","https://openalex.org/W2396077989","https://openalex.org/W4238107016","https://openalex.org/W4253260825"],"related_works":["https://openalex.org/W6885141915","https://openalex.org/W2373288537","https://openalex.org/W2388633065","https://openalex.org/W2359553025","https://openalex.org/W3186903694","https://openalex.org/W7168101543","https://openalex.org/W2910791556","https://openalex.org/W2524642485","https://openalex.org/W2079187611","https://openalex.org/W1610201467"],"abstract_inverted_index":{"High-voltage":[0],"underground":[1,29,34,47,59],"AC":[2,88],"cables":[3,89],"have":[4],"significantly":[5],"different":[6],"electrical":[7,76],"characteristics":[8],"than":[9],"overhead":[10,71],"transmission":[11,72],"lines.":[12],"The":[13],"cable":[14,35,48,75],"sheath":[15],"or":[16],"shield":[17],"grounding":[18,36,64],"method":[19,37],"has":[20],"a":[21],"major":[22],"impact":[23],"on":[24],"the":[25,33,39,51,56,67,81],"zero-sequence":[26],"impedance":[27],"of":[28,58,83],"cables.":[30],"Understanding":[31],"how":[32],"affects":[38],"series":[40],"sequence":[41],"impedances":[42],"is":[43],"very":[44],"fundamental":[45,68],"to":[46],"protection.":[49],"In":[50],"paper":[52],"we":[53,79],"briefly":[54],"discuss":[55,80],"types":[57],"cables,":[60],"their":[61],"bonding":[62],"and":[63,66,74],"methods,":[65],"differences":[69],"between":[70],"lines":[73],"characteristics.":[77],"Finally":[78],"application":[82],"short-circuit":[84],"protection":[85],"for":[86],"high-voltage":[87]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2139485256","counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":6},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":5},{"year":2019,"cited_by_count":3},{"year":2018,"cited_by_count":8},{"year":2017,"cited_by_count":4},{"year":2016,"cited_by_count":6},{"year":2015,"cited_by_count":3},{"year":2014,"cited_by_count":6},{"year":2013,"cited_by_count":3},{"year":2012,"cited_by_count":3}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-06-24T00:00:00"}
