{"id":"https://openalex.org/W2139152932","doi":"https://doi.org/10.1109/61.131110","title":"A new method for measurement of earth fault loop impedance","display_name":"A new method for measurement of earth fault loop impedance","alternate_titles":[],"publication_year":1991,"publication_date":"1991-04-01","ids":{"openalex":"https://openalex.org/W2139152932","doi":"https://doi.org/10.1109/61.131110","mag":"2139152932"},"language":"en","primary_location":{"id":"doi:10.1109/61.131110","doi":"https://doi.org/10.1109/61.131110","is_oa":false,"landing_page_url":"https://doi.org/10.1109/61.131110","pdf_url":null,"source":{"id":"https://openalex.org/S203966947","display_name":"IEEE Transactions on Power Delivery","issn_l":"0885-8977","issn":["0885-8977","1937-4208"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-2","norway-2","poland-140","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Power Delivery","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2139152932"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5004817436","display_name":"Ryszard Roskosz","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I169333911","display_name":"Gda\u0144sk University of Technology","ror":"https://ror.org/006x4sc24","country_code":"PL","type":"education","lineage":["https://openalex.org/I169333911"]}],"countries":["PL"],"is_corresponding":true,"raw_author_name":"R. Roskosz","raw_affiliation_strings":["Technical University of Gda\u0144sk, GdaDsk, Poland","Tech. Univ. of Gdansk, Poland#TAB#"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Technical University of Gda\u0144sk, GdaDsk, Poland","institution_ids":["https://openalex.org/I169333911"]},{"raw_affiliation_string":"Tech. Univ. of Gdansk, Poland#TAB#","institution_ids":["https://openalex.org/I169333911"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5004817436"],"corresponding_institution_ids":["https://openalex.org/I169333911"],"apc_list":{"value":2645,"currency":"USD","value_usd":2645},"apc_paid":null,"fwci":0.7946,"has_fulltext":false,"cited_by_count":9,"citation_normalized_percentile":{"value":0.67095809,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":95},"biblio":{"volume":"6","issue":"2","first_page":"546","last_page":"549"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.6646000146865845,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.6646000146865845,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.1543000042438507,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.1289999932050705,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/low-voltage-systems","display_name":"low-voltage systems","score":0.8289999961853027},{"id":"https://openalex.org/keywords/impedance-measurement","display_name":"impedance measurement","score":0.8759999871253967},{"id":"https://openalex.org/keywords/voltage-sampling","display_name":"voltage sampling","score":0.8159999847412109},{"id":"https://openalex.org/keywords/electrical-safety-testing","display_name":"electrical safety testing","score":0.6510000228881836}],"concepts":[{"id":"https://openalex.org/C176661527","wikidata":"https://www.wikidata.org/wiki/Q746935","display_name":"Reactance","level":3,"score":0.8570634126663208},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.6703343391418457},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6088159680366516},{"id":"https://openalex.org/C184670325","wikidata":"https://www.wikidata.org/wiki/Q512604","display_name":"Loop (graph theory)","level":2,"score":0.5387502908706665},{"id":"https://openalex.org/C140779682","wikidata":"https://www.wikidata.org/wiki/Q210868","display_name":"Sampling (signal processing)","level":3,"score":0.5325984358787537},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5104767084121704},{"id":"https://openalex.org/C172066009","wikidata":"https://www.wikidata.org/wiki/Q5463955","display_name":"Focused Impedance Measurement","level":3,"score":0.4881180226802826},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.46634453535079956},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.42818811535835266},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.40672022104263306},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3856356143951416},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.3465043902397156},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.15925520658493042},{"id":"https://openalex.org/C94915269","wikidata":"https://www.wikidata.org/wiki/Q1834857","display_name":"Detector","level":2,"score":0.12696483731269836},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.09450846910476685},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.09094169735908508},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C114614502","wikidata":"https://www.wikidata.org/wiki/Q76592","display_name":"Combinatorics","level":1,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/61.131110","doi":"https://doi.org/10.1109/61.131110","is_oa":false,"landing_page_url":"https://doi.org/10.1109/61.131110","pdf_url":null,"source":{"id":"https://openalex.org/S203966947","display_name":"IEEE Transactions on Power Delivery","issn_l":"0885-8977","issn":["0885-8977","1937-4208"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-2","norway-2","poland-140","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Power Delivery","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W1977997938","https://openalex.org/W2027880427","https://openalex.org/W4388422690","https://openalex.org/W3119754553","https://openalex.org/W2889383066","https://openalex.org/W2972216876","https://openalex.org/W7196969686","https://openalex.org/W3168519085","https://openalex.org/W138407564","https://openalex.org/W2098817802"],"abstract_inverted_index":{"A":[0],"novel":[1],"method":[2,24,39],"for":[3],"accurate":[4],"and":[5,48],"quick":[6],"measurement":[7,44],"of":[8,22,29,45],"earth":[9],"fault":[10],"loop":[11],"impedance":[12],"in":[13],"a":[14],"low-voltage":[15],"system":[16],"is":[17,25,53],"presented.":[18],"The":[19,38,50],"theoretical":[20],"principle":[21],"the":[23,30,42],"based":[26],"on":[27],"sampling":[28],"tested":[31],"circuit":[32],"voltage":[33],"at":[34],"properly":[35],"chosen":[36],"moments.":[37],"makes":[40],"possible":[41],"simultaneous":[43],"impedance,":[46],"resistance,":[47],"reactance.":[49],"digital":[51],"display":[52],"calibrated":[54],"such":[55],"that":[56],"quantities":[57],"can":[58],"be":[59],"read":[60],"directly.>":[61]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2139152932","counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2014,"cited_by_count":1},{"year":2013,"cited_by_count":1},{"year":2012,"cited_by_count":2}],"updated_date":"2026-11-12T12:28:57.059296","created_date":"2016-06-24T00:00:00"}
