{"id":"https://openalex.org/W2138337489","doi":"https://doi.org/10.1111/j.1600-0668.1993.00023.x","title":"Causes of Poor Sealant Performance in Soil-Gas-Resistant Foundations","display_name":"Causes of Poor Sealant Performance in Soil-Gas-Resistant Foundations","publication_year":1993,"publication_date":"1993-12-01","ids":{"openalex":"https://openalex.org/W2138337489","doi":"https://doi.org/10.1111/j.1600-0668.1993.00023.x","mag":"2138337489"},"language":"en","primary_location":{"id":"doi:10.1111/j.1600-0668.1993.00023.x","doi":"https://doi.org/10.1111/j.1600-0668.1993.00023.x","is_oa":false,"landing_page_url":"https://doi.org/10.1111/j.1600-0668.1993.00023.x","pdf_url":null,"source":{"id":"https://openalex.org/S12992298","display_name":"Indoor Air","issn_l":"0905-6947","issn":["0905-6947","1600-0668"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","dongbi-b","jufo-2","ki-jl-1","norway-1","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320595","host_organization_name":"Wiley","host_organization_lineage":["https://openalex.org/P4310320595"],"host_organization_lineage_names":["Wiley"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Indoor Air","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5077849048","display_name":"Arthur G. Scott","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Arthur Scott","raw_affiliation_strings":["Arthur Scott and Associates, 2020 South Millway Drive, Unit 11, Mississauga, Ontario, Canada L5L 1K2, Telefax 416-828-2389"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Arthur Scott and Associates, 2020 South Millway Drive, Unit 11, Mississauga, Ontario, Canada L5L 1K2, Telefax 416-828-2389","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5077849048"],"corresponding_institution_ids":[],"apc_list":{"value":2490,"currency":"USD","value_usd":2490},"apc_paid":null,"fwci":0.5048,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.57926147,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"3","issue":"4","first_page":"376","last_page":"381"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10946","display_name":"Radioactivity and Radon Measurements","score":0.9854000210762024,"subfield":{"id":"https://openalex.org/subfields/3108","display_name":"Radiation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10946","display_name":"Radioactivity and Radon Measurements","score":0.9854000210762024,"subfield":{"id":"https://openalex.org/subfields/3108","display_name":"Radiation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13923","display_name":"Nuclear and radioactivity studies","score":0.0035000001080334187,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11002","display_name":"Indoor Air Quality and Microbial Exposure","score":0.0027000000700354576,"subfield":{"id":"https://openalex.org/subfields/2307","display_name":"Health, Toxicology and Mutagenesis"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/sealant-performance","display_name":"sealant performance","score":0.7099999785423279},{"id":"https://openalex.org/keywords/permeameter","display_name":"permeameter","score":0.734000027179718},{"id":"https://openalex.org/keywords/concrete-surface-defects","display_name":"concrete surface defects","score":0.7940000295639038},{"id":"https://openalex.org/keywords/radon","display_name":"radon","score":0.48399999737739563}],"concepts":[{"id":"https://openalex.org/C2775883587","wikidata":"https://www.wikidata.org/wiki/Q1427914","display_name":"Sealant","level":2,"score":0.9018750190734863},{"id":"https://openalex.org/C2781349789","wikidata":"https://www.wikidata.org/wiki/Q7169314","display_name":"Permeameter","level":4,"score":0.8608437776565552},{"id":"https://openalex.org/C114932410","wikidata":"https://www.wikidata.org/wiki/Q4698349","display_name":"Air permeability specific surface","level":3,"score":0.6997590065002441},{"id":"https://openalex.org/C120882062","wikidata":"https://www.wikidata.org/wiki/Q28352","display_name":"Permeability (electromagnetism)","level":3,"score":0.6237623691558838},{"id":"https://openalex.org/C2777755289","wikidata":"https://www.wikidata.org/wiki/Q162919","display_name":"Seal (emblem)","level":2,"score":0.6124959588050842},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.555424153804779},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.49888014793395996},{"id":"https://openalex.org/C187320778","wikidata":"https://www.wikidata.org/wiki/Q1349130","display_name":"Geotechnical engineering","level":1,"score":0.49574026465415955},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.3269302546977997},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.1958932876586914},{"id":"https://openalex.org/C159750122","wikidata":"https://www.wikidata.org/wiki/Q96621023","display_name":"Soil water","level":2,"score":0.18374589085578918},{"id":"https://openalex.org/C2779227376","wikidata":"https://www.wikidata.org/wiki/Q6505497","display_name":"Layer (electronics)","level":2,"score":0.1837344765663147},{"id":"https://openalex.org/C159390177","wikidata":"https://www.wikidata.org/wiki/Q9161265","display_name":"Soil science","level":1,"score":0.10206463932991028},{"id":"https://openalex.org/C63184880","wikidata":"https://www.wikidata.org/wiki/Q2783041","display_name":"Hydraulic conductivity","level":3,"score":0.08577227592468262},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.08418884873390198},{"id":"https://openalex.org/C55493867","wikidata":"https://www.wikidata.org/wiki/Q7094","display_name":"Biochemistry","level":1,"score":0.0},{"id":"https://openalex.org/C41625074","wikidata":"https://www.wikidata.org/wiki/Q176088","display_name":"Membrane","level":2,"score":0.0},{"id":"https://openalex.org/C153349607","wikidata":"https://www.wikidata.org/wiki/Q36649","display_name":"Visual arts","level":1,"score":0.0},{"id":"https://openalex.org/C142362112","wikidata":"https://www.wikidata.org/wiki/Q735","display_name":"Art","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1111/j.1600-0668.1993.00023.x","doi":"https://doi.org/10.1111/j.1600-0668.1993.00023.x","is_oa":false,"landing_page_url":"https://doi.org/10.1111/j.1600-0668.1993.00023.x","pdf_url":null,"source":{"id":"https://openalex.org/S12992298","display_name":"Indoor Air","issn_l":"0905-6947","issn":["0905-6947","1600-0668"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","dongbi-b","jufo-2","ki-jl-1","norway-1","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320595","host_organization_name":"Wiley","host_organization_lineage":["https://openalex.org/P4310320595"],"host_organization_lineage_names":["Wiley"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Indoor Air","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":1,"referenced_works":["https://openalex.org/W2473459599"],"related_works":["https://openalex.org/W4409317193","https://openalex.org/W7097822243","https://openalex.org/W2181702110","https://openalex.org/W564441691","https://openalex.org/W2999528148","https://openalex.org/W2122900296","https://openalex.org/W2391518971","https://openalex.org/W2181457267","https://openalex.org/W2369586651","https://openalex.org/W3194356084"],"abstract_inverted_index":{"Sealants":[0],"for":[1,109],"radon-resistant":[2],"foundation":[3],"construction":[4],"must":[5],"seal":[6,19,61,111],"the":[7,24,27,31,50,64,78,101,117,137],"gap":[8],"between":[9],"concrete":[10,37,70,96],"sections.":[11],"Modern":[12],"sealants":[13],"have":[14],"such":[15],"low":[16],"permeability":[17,25,35,67,83,102],"that":[18,29],"performance":[20],"depends":[21],"only":[22,118],"on":[23,95],"of":[26,36,68,77,120,136],"material":[28],"contacts":[30],"sealant.":[32],"The":[33,66],"surface":[34,79,82,91,138],"walls":[38],"and":[39,123,140],"floors":[40],"was":[41],"measured":[42],"by":[43,53],"a":[44,54,58],"specially":[45],"designed":[46],"permeameter,":[47],"which":[48,99],"measures":[49],"airflow":[51],"induced":[52],"pressure":[55],"difference":[56],"across":[57],"temporary":[59],"test":[60],"applied":[62],"to":[63,87,103,113],"surface.":[65],"bulk":[69],"is":[71],"about":[72],"10\u221216":[73,88],"m2.":[74,89],"Areas":[75],"free":[76],"defects":[80,92],"had":[81],"ranging":[84],"from":[85],"10\u221214":[86],"However,":[90],"are":[93],"common":[94],"wall":[97],"surfaces,":[98],"increase":[100],">":[104],"10\u221212":[105],"m2,":[106],"too":[107],"high":[108],"standard":[110],"designs":[112],"be":[114],"adequate":[115],"as":[116],"method":[119],"soil":[121],"gas":[122],"radon":[124],"exclusion.":[125],"Radon-resistant":[126],"seals":[127],"require":[128],"either":[129],"extended":[130],"contact":[131],"widths":[132],"or":[133],"mechanical":[134],"removal":[135],"layer":[139],"defects.":[141]},"counts_by_year":[],"updated_date":"2026-10-30T12:39:25.321706","created_date":"2016-06-24T00:00:00"}
