{"id":"https://openalex.org/W2136361687","doi":"https://doi.org/10.1109/cmd.2008.4580324","title":"Application of combined PD sensor for GIS PD detection and condition monitoring","display_name":"Application of combined PD sensor for GIS PD detection and condition monitoring","alternate_titles":[],"publication_year":2008,"publication_date":"2008-01-01","ids":{"openalex":"https://openalex.org/W2136361687","doi":"https://doi.org/10.1109/cmd.2008.4580324","mag":"2136361687"},"language":"en","primary_location":{"id":"doi:10.1109/cmd.2008.4580324","doi":"https://doi.org/10.1109/cmd.2008.4580324","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cmd.2008.4580324","pdf_url":null,"source":{"id":"https://openalex.org/S4363608139","display_name":"International Conference on Condition Monitoring and Diagnosis (CMD)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2008 International Conference on Condition Monitoring and Diagnosis","raw_type":"proceedings-article"},"parent_works":[],"lineage":["https://openalex.org/W2136361687"],"child_works_count":0,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Chen Min","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Chen Min","raw_affiliation_strings":["SE Technology Limited, Hong Kong, China","SE Technol. Ltd., Hong Kong"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"SE Technology Limited, Hong Kong, China","institution_ids":[]},{"raw_affiliation_string":"SE Technol. Ltd., Hong Kong","institution_ids":[]}]},{"author_position":"middle","author":{"id":null,"display_name":"Koji Urano","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Koji Urano","raw_affiliation_strings":["SE Technology Limited, Hong Kong, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"SE Technology Limited, Hong Kong, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5059911281","display_name":"You\u2010Cheng Li","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Li You-Cheng","raw_affiliation_strings":["Zhuhai Electric Power Corporation, China","Zhuhai Electric Power Corp., China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Zhuhai Electric Power Corporation, China","institution_ids":[]},{"raw_affiliation_string":"Zhuhai Electric Power Corp., China","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5058597099","display_name":"Atsuhide Jinno","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4405264454","display_name":"J-Power Systems Corporation (Japan)","ror":"https://ror.org/01zwa1v37","country_code":"JP","type":"company","lineage":["https://openalex.org/I4405264454"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Atsuhide Jinno","raw_affiliation_strings":["J-Power Systems Corporation, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"J-Power Systems Corporation, Japan","institution_ids":["https://openalex.org/I4405264454"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.8667,"has_fulltext":false,"cited_by_count":15,"citation_normalized_percentile":{"value":0.63093161,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"456","last_page":"460"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.9854000210762024,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.9854000210762024,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.0024999999441206455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12692","display_name":"Magnetic Field Sensors Techniques","score":0.000699999975040555,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/partial-discharge","display_name":"partial discharge","score":0.875},{"id":"https://openalex.org/keywords/gas-insulated-switchgear","display_name":"gas-insulated switchgear","score":0.9769999980926514},{"id":"https://openalex.org/keywords/partial-discharge-localization","display_name":"partial discharge localization","score":0.7300000190734863},{"id":"https://openalex.org/keywords/acoustic-signal-detection","display_name":"acoustic signal detection","score":0.6859999895095825},{"id":"https://openalex.org/keywords/combined-sensor","display_name":"combined sensor","score":0.7639999985694885},{"id":"https://openalex.org/keywords/condition-monitoring","display_name":"condition monitoring","score":0.8650000095367432},{"id":"https://openalex.org/keywords/time-difference-of-arrival","display_name":"time difference of arrival","score":0.6819999814033508}],"concepts":[{"id":"https://openalex.org/C130143024","wikidata":"https://www.wikidata.org/wiki/Q1929972","display_name":"Partial discharge","level":3,"score":0.8296988010406494},{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.5883662700653076},{"id":"https://openalex.org/C2780167933","wikidata":"https://www.wikidata.org/wiki/Q1550652","display_name":"Pulse (music)","level":3,"score":0.5514836311340332},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.5208064317703247},{"id":"https://openalex.org/C41856607","wikidata":"https://www.wikidata.org/wiki/Q483130","display_name":"Geographic information system","level":2,"score":0.4818497896194458},{"id":"https://openalex.org/C55000061","wikidata":"https://www.wikidata.org/wiki/Q24894777","display_name":"Current sensor","level":3,"score":0.4688096344470978},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.4671342372894287},{"id":"https://openalex.org/C62649853","wikidata":"https://www.wikidata.org/wiki/Q199687","display_name":"Remote sensing","level":1,"score":0.4444849491119385},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3784519135951996},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.3395553231239319},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.23638159036636353},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.22963273525238037},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.22199931740760803},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.15892961621284485},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.15492716431617737},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.11849826574325562},{"id":"https://openalex.org/C94915269","wikidata":"https://www.wikidata.org/wiki/Q1834857","display_name":"Detector","level":2,"score":0.09376326203346252},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/cmd.2008.4580324","doi":"https://doi.org/10.1109/cmd.2008.4580324","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cmd.2008.4580324","pdf_url":null,"source":{"id":"https://openalex.org/S4363608139","display_name":"International Conference on Condition Monitoring and Diagnosis (CMD)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2008 International Conference on Condition Monitoring and Diagnosis","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.5378999710083008,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":1,"referenced_works":["https://openalex.org/W2137355952"],"related_works":["https://openalex.org/W1894941525","https://openalex.org/W2359218046","https://openalex.org/W4409499389","https://openalex.org/W7167013307","https://openalex.org/W2742401515","https://openalex.org/W4409372840","https://openalex.org/W4282020657","https://openalex.org/W4389578992","https://openalex.org/W2369210541","https://openalex.org/W2361359289"],"abstract_inverted_index":{"It":[0],"was":[1],"reported":[2],"previously":[3],"that":[4,92],"partial":[5],"discharge":[6],"(PD)":[7],"existing":[8],"in":[9,27],"GIS":[10,39],"can":[11,96],"be":[12,97],"localized":[13],"with":[14],"a":[15],"PD":[16,25,54,70,87],"localization":[17,47],"method":[18],"based":[19],"on":[20],"the":[21,38,46,53,67,79,85],"time":[22],"difference":[23],"of":[24],"detection,":[26],"which":[28],"more":[29],"than":[30],"one":[31],"pulse":[32,74],"current":[33,75],"sensors":[34,71],"are":[35],"installed":[36],"at":[37],"sealing":[40],"end":[41],"or":[42],"cable":[43],"termination.":[44],"However,":[45],"accuracy":[48,68,95],"is":[49,57],"not":[50,61],"satisfactory":[51],"since":[52],"propagation":[55],"speed":[56],"too":[58],"high":[59],"and":[60,76],"average":[62],"inside":[63],"GIS.":[64],"To":[65],"increase":[66],"combined":[69],"to":[72,77],"detect":[73],"catch":[78],"acoustic":[80],"signal":[81],"were":[82],"applied":[83],"for":[84],"on-site":[86],"localization.":[88],"The":[89],"result":[90],"shows":[91],"higher":[93],"location":[94],"obtained.":[98]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2136361687","counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":2},{"year":2013,"cited_by_count":1},{"year":2012,"cited_by_count":2}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-06-24T00:00:00"}