{"id":"https://openalex.org/W2136014753","doi":"https://doi.org/10.1109/iecon.2004.1432161","title":"A study on the loss model and characteristic comparison of three-level converter and full-bridge converter through the conduction loss analysis of power devices","display_name":"A study on the loss model and characteristic comparison of three-level converter and full-bridge converter through the conduction loss analysis of power devices","publication_year":2005,"publication_date":"2005-05-24","ids":{"openalex":"https://openalex.org/W2136014753","doi":"https://doi.org/10.1109/iecon.2004.1432161","mag":"2136014753"},"language":"en","primary_location":{"id":"doi:10.1109/iecon.2004.1432161","doi":"https://doi.org/10.1109/iecon.2004.1432161","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2004.1432161","pdf_url":null,"source":{"id":"https://openalex.org/S4210172894","display_name":"Annual Conference of the IEEE Industrial Electronics Society (IECON)","issn_l":"1553-572X","issn":["1553-572X","2577-1647"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["jufo-1","norway-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"30th Annual Conference of IEEE Industrial Electronics Society, 2004. IECON 2004","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5030726734","display_name":"Jin-Yong Bae","orcid":"https://orcid.org/0000-0003-0554-3621","observed_orcids":["https://orcid.org/0000-0003-0554-3621"]},"institutions":[{"id":"https://openalex.org/I205490536","display_name":"Dongguk University","ror":"https://ror.org/057q6n778","country_code":"KR","type":"education","lineage":["https://openalex.org/I205490536"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Jin-Yong Bae","raw_affiliation_strings":["Department of Electrical Engineering, Dongguk University, Seoul, South Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Dongguk University, Seoul, South Korea","institution_ids":["https://openalex.org/I205490536"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100329378","display_name":"Yong Kim","orcid":"https://orcid.org/0000-0002-0264-1915","observed_orcids":["https://orcid.org/0000-0002-0264-1915"]},"institutions":[{"id":"https://openalex.org/I205490536","display_name":"Dongguk University","ror":"https://ror.org/057q6n778","country_code":"KR","type":"education","lineage":["https://openalex.org/I205490536"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Yong Kim","raw_affiliation_strings":["Department of Electrical Engineering, Dongguk University, Seoul, South Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Dongguk University, Seoul, South Korea","institution_ids":["https://openalex.org/I205490536"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100429195","display_name":"Donghyun Lee","orcid":"https://orcid.org/0000-0001-9117-5647","observed_orcids":["https://orcid.org/0000-0001-9117-5647"]},"institutions":[{"id":"https://openalex.org/I205490536","display_name":"Dongguk University","ror":"https://ror.org/057q6n778","country_code":"KR","type":"education","lineage":["https://openalex.org/I205490536"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Dong-Hyun Lee","raw_affiliation_strings":["Department of Electrical Engineering, Dongguk University, Seoul, South Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Dongguk University, Seoul, South Korea","institution_ids":["https://openalex.org/I205490536"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5086903003","display_name":"Soon-Do Kwon","orcid":"https://orcid.org/0000-0002-9377-8158","observed_orcids":["https://orcid.org/0000-0002-9377-8158"]},"institutions":[{"id":"https://openalex.org/I4792177","display_name":"Daelim University College","ror":"https://ror.org/00hn0mq04","country_code":"KR","type":"education","lineage":["https://openalex.org/I4792177"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Soon-Do Kwon","raw_affiliation_strings":["Daelim College, Anyang, Gyeonggi, South Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Daelim College, Anyang, Gyeonggi, South Korea","institution_ids":["https://openalex.org/I4792177"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5089722465","display_name":"Pill-Soo Kim","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4792177","display_name":"Daelim University College","ror":"https://ror.org/00hn0mq04","country_code":"KR","type":"education","lineage":["https://openalex.org/I4792177"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Pill-Soo Kim","raw_affiliation_strings":["Daelim College, Anyang, Gyeonggi, South Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Daelim College, Anyang, Gyeonggi, South Korea","institution_ids":["https://openalex.org/I4792177"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5032935203","display_name":"Dae Hee Han","orcid":"https://orcid.org/0000-0002-5004-9721","observed_orcids":["https://orcid.org/0000-0002-5004-9721"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Dae-Hee Han","raw_affiliation_strings":["Dongah Elecomm Corporation, Yongin si, Gyeonggi, South Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dongah Elecomm Corporation, Yongin si, Gyeonggi, South Korea","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.1286,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.72292167,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":95},"biblio":{"volume":"3","issue":null,"first_page":"2314","last_page":"2320"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9726999998092651,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9726999998092651,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.023900000378489494,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10361","display_name":"Silicon Carbide Semiconductor Technologies","score":0.000699999975040555,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/three-level-converter","display_name":"three-level converter","score":0.9580000042915344},{"id":"https://openalex.org/keywords/full-bridge-converter","display_name":"full-bridge converter","score":1.0},{"id":"https://openalex.org/keywords/conduction-losses","display_name":"conduction losses","score":0.8180000185966492},{"id":"https://openalex.org/keywords/power-device-losses","display_name":"power device losses","score":0.7910000085830688},{"id":"https://openalex.org/keywords/loss-modeling","display_name":"loss modeling","score":0.765999972820282},{"id":"https://openalex.org/keywords/converter-efficiency","display_name":"converter efficiency","score":0.8560000061988831},{"id":"https://openalex.org/keywords/power-converters","display_name":"power converters","score":0.4339999854564667},{"id":"https://openalex.org/keywords/loss-analysis","display_name":"loss analysis","score":0.39100000262260437}],"concepts":[{"id":"https://openalex.org/C2985627981","wikidata":"https://www.wikidata.org/wiki/Q828827","display_name":"Power loss","level":3,"score":0.5998560190200806},{"id":"https://openalex.org/C172100665","wikidata":"https://www.wikidata.org/wiki/Q7465774","display_name":"Thermal conduction","level":2,"score":0.5398764610290527},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.5062934160232544},{"id":"https://openalex.org/C78336795","wikidata":"https://www.wikidata.org/wiki/Q760134","display_name":"Boost converter","level":3,"score":0.49451944231987},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4826089143753052},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.47484639286994934},{"id":"https://openalex.org/C42043438","wikidata":"https://www.wikidata.org/wiki/Q1671740","display_name":"Buck\u2013boost converter","level":4,"score":0.4700920581817627},{"id":"https://openalex.org/C100329506","wikidata":"https://www.wikidata.org/wiki/Q336439","display_name":"\u0106uk converter","level":4,"score":0.45996883511543274},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.4566236734390259},{"id":"https://openalex.org/C100776233","wikidata":"https://www.wikidata.org/wiki/Q2532492","display_name":"Bridge (graph theory)","level":2,"score":0.428815633058548},{"id":"https://openalex.org/C150818752","wikidata":"https://www.wikidata.org/wiki/Q83804","display_name":"Buck converter","level":3,"score":0.4101472795009613},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3850715756416321},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.36031362414360046},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.3000448942184448},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.17397141456604004},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.14675495028495789},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.0},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.0},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon.2004.1432161","doi":"https://doi.org/10.1109/iecon.2004.1432161","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2004.1432161","pdf_url":null,"source":{"id":"https://openalex.org/S4210172894","display_name":"Annual Conference of the IEEE Industrial Electronics Society (IECON)","issn_l":"1553-572X","issn":["1553-572X","2577-1647"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["jufo-1","norway-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"30th Annual Conference of IEEE Industrial Electronics Society, 2004. IECON 2004","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.878000020980835},{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.5378999710083008}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":2,"referenced_works":["https://openalex.org/W1865733354","https://openalex.org/W2167281613"],"related_works":["https://openalex.org/W3002986683","https://openalex.org/W2221760863","https://openalex.org/W2068971161","https://openalex.org/W2125243049","https://openalex.org/W2904179369","https://openalex.org/W2236715659","https://openalex.org/W2768345419","https://openalex.org/W143712214","https://openalex.org/W2376039365","https://openalex.org/W7128445701"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"the":[3,18,27,43,50,54,64],"loss":[4,20,44],"model":[5],"and":[6,13,49],"characteristic":[7],"comparison":[8],"of":[9,22,30,34,46,63],"a":[10,14,35,39],"three-level":[11,40],"converter":[12,16,37],"full-bridge":[15,36],"through":[17],"conduction":[19],"analysis":[21,45,65],"power":[23],"devices.":[24],"It":[25],"shows":[26],"main":[28],"reason":[29],"efficiency":[31],"diminution,":[32],"comparing":[33],"with":[38,68],"converter.":[41],"Also,":[42],"each":[47],"component":[48],"various":[51],"losses":[52],"in":[53,58],"circuit":[55],"are":[56],"proposed":[57],"this":[59],"paper.":[60],"The":[61],"result":[62],"is":[66],"verified":[67],"2.5":[69],"kW":[70],"prototype.":[71]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2015,"cited_by_count":1}],"updated_date":"2026-11-07T11:25:07.637180","created_date":"2016-06-24T00:00:00"}