{"id":"https://openalex.org/W2129189348","doi":"https://doi.org/10.1109/tdei.2007.302881","title":"Aging of silicone rubber composite insulators on 400 kV transmission lines","display_name":"Aging of silicone rubber composite insulators on 400 kV transmission lines","alternate_titles":[],"publication_year":2007,"publication_date":"2007-02-01","ids":{"openalex":"https://openalex.org/W2129189348","doi":"https://doi.org/10.1109/tdei.2007.302881","mag":"2129189348"},"language":"en","primary_location":{"id":"doi:10.1109/tdei.2007.302881","doi":"https://doi.org/10.1109/tdei.2007.302881","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tdei.2007.302881","pdf_url":null,"source":{"id":"https://openalex.org/S19003042","display_name":"IEEE Transactions on Dielectrics and Electrical Insulation","issn_l":"1070-9878","issn":["1070-9878","1558-4135"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","jufo-2","ki-jl-1","norway-1","poland-100","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Dielectrics and Electrical Insulation","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2129189348"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://research.manchester.ac.uk/en/publications/cb7a4c6c-c60d-4fb7-8ac1-f5223b98a69f","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5016482802","display_name":"Simon Rowland","orcid":"https://orcid.org/0000-0003-0811-1509","observed_orcids":["https://orcid.org/0000-0003-0811-1509"]},"institutions":[{"id":"https://openalex.org/I28407311","display_name":"University of Manchester","ror":"https://ror.org/027m9bs27","country_code":"GB","type":"education","lineage":["https://openalex.org/I28407311"]}],"countries":["GB"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"S. Rowland","raw_affiliation_strings":["School of Electrical and Electronic Engineering, University of Manchester, Institute of Science and Technology, Manchester, UK","Dept. of Electr. & Electron. Eng., Manchester Univ"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Electrical and Electronic Engineering, University of Manchester, Institute of Science and Technology, Manchester, UK","institution_ids":["https://openalex.org/I28407311"]},{"raw_affiliation_string":"Dept. of Electr. & Electron. Eng., Manchester Univ","institution_ids":["https://openalex.org/I28407311"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Y. Xiong","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I28407311","display_name":"University of Manchester","ror":"https://ror.org/027m9bs27","country_code":"GB","type":"education","lineage":["https://openalex.org/I28407311"]}],"countries":["GB"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Y. Xiong","raw_affiliation_strings":["School of Electrical and Electronic Engineering, University of Manchester, Institute of Science and Technology, Manchester, UK","Dept. of Electr. & Electron. Eng., Manchester Univ"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Electrical and Electronic Engineering, University of Manchester, Institute of Science and Technology, Manchester, UK","institution_ids":["https://openalex.org/I28407311"]},{"raw_affiliation_string":"Dept. of Electr. & Electron. Eng., Manchester Univ","institution_ids":["https://openalex.org/I28407311"]}]},{"author_position":"middle","author":{"id":null,"display_name":"J. Robertson","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I28407311","display_name":"University of Manchester","ror":"https://ror.org/027m9bs27","country_code":"GB","type":"education","lineage":["https://openalex.org/I28407311"]}],"countries":["GB"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"J. Robertson","raw_affiliation_strings":["School of Electrical and Electronic Engineering, University of Manchester, Institute of Science and Technology, Manchester, UK","Dept. of Electr. & Electron. Eng., Manchester Univ"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Electrical and Electronic Engineering, University of Manchester, Institute of Science and Technology, Manchester, UK","institution_ids":["https://openalex.org/I28407311"]},{"raw_affiliation_string":"Dept. of Electr. & Electron. Eng., Manchester Univ","institution_ids":["https://openalex.org/I28407311"]}]},{"author_position":"last","author":{"id":null,"display_name":"S. Hoffmann","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210155979","display_name":"National Grid (United Kingdom)","ror":"https://ror.org/04hp86393","country_code":"GB","type":"company","lineage":["https://openalex.org/I4210155979"]}],"countries":["GB"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"S. Hoffmann","raw_affiliation_strings":["National Grid Company Limited, Warwick, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Grid Company Limited, Warwick, UK","institution_ids":["https://openalex.org/I4210155979"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":2645,"currency":"USD","value_usd":2645},"apc_paid":null,"fwci":3.8647,"has_fulltext":true,"cited_by_count":78,"citation_normalized_percentile":{"value":0.92588529,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":88,"max":99},"biblio":{"volume":"14","issue":"1","first_page":"130","last_page":"136"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/insulator-aging","display_name":"insulator aging","score":0.9049999713897705},{"id":"https://openalex.org/keywords/hydrophobicity","display_name":"hydrophobicity","score":0.9580000042915344},{"id":"https://openalex.org/keywords/contact-angle","display_name":"contact angle","score":0.972000002861023},{"id":"https://openalex.org/keywords/400-kv-transmission-lines","display_name":"400 kV transmission lines","score":0.8960000276565552},{"id":"https://openalex.org/keywords/coastal-environment","display_name":"littoral zone","score":0.5839999914169312},{"id":"https://openalex.org/keywords/insulator-sheds","display_name":"insulator sheds","score":0.7670000195503235},{"id":"https://openalex.org/keywords/discoloration","display_name":"discoloration","score":0.9589999914169312},{"id":"https://openalex.org/keywords/insulator-strings","display_name":"insulator strings","score":0.4740000069141388}],"concepts":[{"id":"https://openalex.org/C2776290925","wikidata":"https://www.wikidata.org/wiki/Q4115245","display_name":"Silicone rubber","level":2,"score":0.9216552972793579},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.7113730907440186},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.696171760559082},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.5687459111213684},{"id":"https://openalex.org/C6556556","wikidata":"https://www.wikidata.org/wiki/Q899239","display_name":"Contact angle","level":2,"score":0.5666017532348633},{"id":"https://openalex.org/C212702","wikidata":"https://www.wikidata.org/wiki/Q178150","display_name":"Insulator (electricity)","level":2,"score":0.5550442934036255},{"id":"https://openalex.org/C104779481","wikidata":"https://www.wikidata.org/wiki/Q50707","display_name":"Composite number","level":2,"score":0.5512875914573669},{"id":"https://openalex.org/C176933379","wikidata":"https://www.wikidata.org/wiki/Q131877","display_name":"Natural rubber","level":2,"score":0.543391227722168},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.49605926871299744},{"id":"https://openalex.org/C166504685","wikidata":"https://www.wikidata.org/wiki/Q843905","display_name":"Circumference","level":2,"score":0.4528367221355438},{"id":"https://openalex.org/C33441834","wikidata":"https://www.wikidata.org/wiki/Q693004","display_name":"Transmission line","level":2,"score":0.4192875325679779},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.39940598607063293},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.08406928181648254},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.07589021325111389},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/tdei.2007.302881","doi":"https://doi.org/10.1109/tdei.2007.302881","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tdei.2007.302881","pdf_url":null,"source":{"id":"https://openalex.org/S19003042","display_name":"IEEE Transactions on Dielectrics and Electrical Insulation","issn_l":"1070-9878","issn":["1070-9878","1558-4135"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","jufo-2","ki-jl-1","norway-1","poland-100","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Dielectrics and Electrical Insulation","raw_type":"journal-article"},{"id":"pmh:oai:pure.atira.dk:openaire/cb7a4c6c-c60d-4fb7-8ac1-f5223b98a69f","doi":null,"is_oa":true,"landing_page_url":"https://research.manchester.ac.uk/en/publications/cb7a4c6c-c60d-4fb7-8ac1-f5223b98a69f","pdf_url":null,"source":{"id":"https://openalex.org/S4306400662","display_name":"Research Explorer (The University of Manchester)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I28407311","host_organization_name":"University of Manchester","host_organization_lineage":["https://openalex.org/I28407311"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Rowland, S M, Xiong, Y, Robertson, J & Hoffmann, S 2007, 'Aging of silicone rubber composite insulators on 400 kV transmission lines', IEEE Transactions on Dielectrics and Electrical Insulation, vol. 14, no. 1, pp. 130-136. https://doi.org/10.1109/TDEI.2007.302881","raw_type":"info:eu-repo/semantics/article"},{"id":"pmh:oai:CiteSeerX.psu:10.1.1.334.1967","doi":null,"is_oa":false,"landing_page_url":"http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.334.1967","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"http://www.eee.manchester.ac.uk/research/groups/eeps/publications/sci/hvpsp/rowland_2007B.pdf","raw_type":"text"}],"best_oa_location":{"id":"pmh:oai:pure.atira.dk:openaire/cb7a4c6c-c60d-4fb7-8ac1-f5223b98a69f","doi":null,"is_oa":true,"landing_page_url":"https://research.manchester.ac.uk/en/publications/cb7a4c6c-c60d-4fb7-8ac1-f5223b98a69f","pdf_url":null,"source":{"id":"https://openalex.org/S4306400662","display_name":"Research Explorer (The University of Manchester)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I28407311","host_organization_name":"University of Manchester","host_organization_lineage":["https://openalex.org/I28407311"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Rowland, S M, Xiong, Y, Robertson, J & Hoffmann, S 2007, 'Aging of silicone rubber composite insulators on 400 kV transmission lines', IEEE Transactions on Dielectrics and Electrical Insulation, vol. 14, no. 1, pp. 130-136. https://doi.org/10.1109/TDEI.2007.302881","raw_type":"info:eu-repo/semantics/article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","score":0.5378999710083008,"display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":20,"referenced_works":["https://openalex.org/W1588851994","https://openalex.org/W1923966231","https://openalex.org/W1968387579","https://openalex.org/W1971070332","https://openalex.org/W1974200773","https://openalex.org/W1992954462","https://openalex.org/W2053327152","https://openalex.org/W2062978816","https://openalex.org/W2091497704","https://openalex.org/W2095301240","https://openalex.org/W2101121889","https://openalex.org/W2111055103","https://openalex.org/W2118092936","https://openalex.org/W2119098205","https://openalex.org/W2121791893","https://openalex.org/W2141920786","https://openalex.org/W2152303625","https://openalex.org/W2287051918","https://openalex.org/W4233468095","https://openalex.org/W4247705339"],"related_works":["https://openalex.org/W2109507414","https://openalex.org/W2032246859","https://openalex.org/W2541783054","https://openalex.org/W2083189368","https://openalex.org/W2535548046","https://openalex.org/W2544544053","https://openalex.org/W4379525093","https://openalex.org/W2366545629","https://openalex.org/W4378841457"],"abstract_inverted_index":{"A":[0],"number":[1],"of":[2,13,27,41,68,89,107,114],"silicone":[3],"rubber":[4],"composite":[5],"insulators":[6,109],"have":[7],"been":[8],"examined":[9],"following":[10],"15":[11],"years":[12],"service":[14],"on":[15,86,104,110],"a":[16,39],"coastal":[17],"400":[18],"kV":[19],"transmission":[20],"line":[21],"in":[22,65,83,92],"the":[23,49,54,59,66,69,90,105,108],"UK.":[24],"Extensive":[25],"measurements":[26],"their":[28,42,77],"hydrophobicity,":[29],"as":[30],"determined":[31],"by":[32],"contact":[33,61,112],"angle,":[34],"are":[35],"given":[36],"along":[37],"with":[38,58],"description":[40],"appearance.":[43],"The":[44,71,97],"hydrophobicity":[45,95],"change":[46,99],"varied":[47],"from":[48],"low":[50],"voltage":[51,56],"end":[52,57],"to":[53,94,100],"high":[55],"lowest":[60],"angles":[62,113],"being":[63],"found":[64],"middle":[67],"string.":[70],"sheds":[72],"also":[73],"aged":[74],"differently":[75],"around":[76],"circumference":[78],"and":[79],"this":[80],"was":[81,102],"reflected":[82],"discoloration":[84],"differences":[85],"different":[87],"sides":[88],"insulator,":[91],"addition":[93],"changes.":[96],"greatest":[98],"properties":[101],"witnessed":[103],"core":[106],"which":[111],"less":[115],"than":[116],"70":[117],"degrees":[118],"were":[119],"recorded":[120]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2129189348","counts_by_year":[{"year":2026,"cited_by_count":3},{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":4},{"year":2023,"cited_by_count":6},{"year":2022,"cited_by_count":4},{"year":2021,"cited_by_count":4},{"year":2020,"cited_by_count":5},{"year":2019,"cited_by_count":3},{"year":2018,"cited_by_count":8},{"year":2017,"cited_by_count":7},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":2},{"year":2013,"cited_by_count":2},{"year":2012,"cited_by_count":8}],"updated_date":"2026-11-20T13:11:24.684918","created_date":"2016-06-24T00:00:00"}