{"id":"https://openalex.org/W2129120944","doi":"https://doi.org/10.1109/tns.1983.4332662","title":"Iconic Displays, Rankine Cycles and Human Factors for Control Rooms of Nuclear Power Plants","display_name":"Iconic Displays, Rankine Cycles and Human Factors for Control Rooms of Nuclear Power Plants","publication_year":1983,"publication_date":"1983-01-01","ids":{"openalex":"https://openalex.org/W2129120944","doi":"https://doi.org/10.1109/tns.1983.4332662","mag":"2129120944"},"language":"en","primary_location":{"id":"doi:10.1109/tns.1983.4332662","doi":"https://doi.org/10.1109/tns.1983.4332662","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tns.1983.4332662","pdf_url":null,"source":{"id":"https://openalex.org/S14279044","display_name":"IEEE Transactions on Nuclear Science","issn_l":"0018-9499","issn":["0018-9499","1558-1578"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-1","norway-1","poland-70","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Nuclear Science","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5041436619","display_name":"Leo Beltracchi","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"L. Beltracchi","raw_affiliation_strings":["Iconic Displays, Rankine Cycles, Human Factors For Control Rooms Of Nuclear Power Plants"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Iconic Displays, Rankine Cycles, Human Factors For Control Rooms Of Nuclear Power Plants","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5041436619"],"corresponding_institution_ids":[],"apc_list":{"value":2645,"currency":"USD","value_usd":2645},"apc_paid":null,"fwci":1.3009,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.78504673,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"30","issue":"3","first_page":"1856","last_page":"1861"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10525","display_name":"Human-Automation Interaction and Safety","score":0.6304000020027161,"subfield":{"id":"https://openalex.org/subfields/3307","display_name":"Human Factors and Ergonomics"},"field":{"id":"https://openalex.org/fields/33","display_name":"Social Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}},"topics":[{"id":"https://openalex.org/T10525","display_name":"Human-Automation Interaction and Safety","score":0.6304000020027161,"subfield":{"id":"https://openalex.org/subfields/3307","display_name":"Human Factors and Ergonomics"},"field":{"id":"https://openalex.org/fields/33","display_name":"Social Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}},{"id":"https://openalex.org/T10799","display_name":"Data Visualization and Analytics","score":0.16660000383853912,"subfield":{"id":"https://openalex.org/subfields/1704","display_name":"Computer Graphics and Computer-Aided Design"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11357","display_name":"Risk and Safety Analysis","score":0.034299999475479126,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/nuclear-power-plant-control-rooms","display_name":"nuclear power plant control rooms","score":0.8180000185966492},{"id":"https://openalex.org/keywords/rankine-cycle","display_name":"Rankine cycle","score":0.9160000085830688},{"id":"https://openalex.org/keywords/pressurized-water-reactor","display_name":"pressurized water reactor","score":0.7559999823570251},{"id":"https://openalex.org/keywords/human-factors","display_name":"human factors","score":0.8360000252723694},{"id":"https://openalex.org/keywords/design-basis-accidents","display_name":"design basis accidents","score":0.7630000114440918},{"id":"https://openalex.org/keywords/operator-decision-making","display_name":"operator decision-making","score":0.5759999752044678},{"id":"https://openalex.org/keywords/heat-transfer-visualization","display_name":"heat transfer visualization","score":0.6389999985694885},{"id":"https://openalex.org/keywords/transient-operation","display_name":"transient operation","score":0.4860000014305115},{"id":"https://openalex.org/keywords/sensor-data-interpretation","display_name":"sensor data interpretation","score":0.5260000228881836},{"id":"https://openalex.org/keywords/operator-workload","display_name":"operator workload","score":0.5320000052452087},{"id":"https://openalex.org/keywords/human-machine-interaction","display_name":"human-machine interaction","score":0.4009999930858612}],"concepts":[{"id":"https://openalex.org/C44431628","wikidata":"https://www.wikidata.org/wiki/Q207488","display_name":"Degree Rankine","level":2,"score":0.6453700661659241},{"id":"https://openalex.org/C513653683","wikidata":"https://www.wikidata.org/wiki/Q12739","display_name":"Nuclear power","level":2,"score":0.6214693188667297},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.5259749293327332},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4647139310836792},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.45883908867836},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.43983617424964905},{"id":"https://openalex.org/C116915560","wikidata":"https://www.wikidata.org/wiki/Q83504","display_name":"Nuclear engineering","level":1,"score":0.4334239959716797},{"id":"https://openalex.org/C2779697362","wikidata":"https://www.wikidata.org/wiki/Q390516","display_name":"Control room","level":2,"score":0.4187565743923187},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.3787667155265808},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.33617353439331055},{"id":"https://openalex.org/C185544564","wikidata":"https://www.wikidata.org/wiki/Q81197","display_name":"Nuclear physics","level":1,"score":0.3089035749435425},{"id":"https://openalex.org/C21880701","wikidata":"https://www.wikidata.org/wiki/Q2144042","display_name":"Process engineering","level":1,"score":0.22588521242141724},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tns.1983.4332662","doi":"https://doi.org/10.1109/tns.1983.4332662","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tns.1983.4332662","pdf_url":null,"source":{"id":"https://openalex.org/S14279044","display_name":"IEEE Transactions on Nuclear Science","issn_l":"0018-9499","issn":["0018-9499","1558-1578"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-1","norway-1","poland-70","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Nuclear Science","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":1,"referenced_works":["https://openalex.org/W820711994"],"related_works":["https://openalex.org/W2157162103","https://openalex.org/W2037800474","https://openalex.org/W1977181446","https://openalex.org/W269121049","https://openalex.org/W1526711811","https://openalex.org/W2146579722","https://openalex.org/W2003218740","https://openalex.org/W150985461","https://openalex.org/W2063731246","https://openalex.org/W2073187503"],"abstract_inverted_index":{"This":[0],"report":[1],"discusses":[2],"a":[3,6,23,36,119],"concept":[4],"for":[5,39],"nuclear":[7],"power":[8,41,59,74],"plant":[9,17,60,107],"(NPP)":[10],"process":[11,125],"iconic":[12,28,98],"display":[13,29,44,79,99],"to":[14,133],"model":[15,38],"the":[16,19,33,40,50,58,73,78,86,106,122,127,130,134,137,144,154,156,171,174,182],"in":[18,57,65,72,143],"control":[20],"room":[21],"of":[22,55,85,94,105,121,146,184],"pressurized-water":[24],"reactor":[25,131],"(PWR).":[26],"The":[27,43,97],"is":[30,63],"based":[31],"on":[32,49],"Rankine":[34],"Cycle,":[35],"thermodynamic":[37],"cycle.":[42],"image":[45,80],"contains":[46],"coded":[47,141],"information":[48,142],"generation,":[51],"transport,":[52],"and":[53,69,111,114,163,180],"removal":[54],"heat":[56,123,128,135],"process.":[61,108],"It":[62,109],"useful":[64],"evaluating":[66],"both":[67],"steady-state":[68],"transient":[70],"operation":[71],"plant.":[75],"Elements":[76],"within":[77],"become":[81],"distorted":[82],"during":[83],"many":[84],"significant":[87],"design-basis":[88],"accidents":[89],"thus":[90,169],"facilitating":[91],"operator":[92,175],"recognition":[93],"these":[95],"events.":[96],"serves":[100],"as":[101],"an":[102],"overview":[103],"monitor":[104],"structures":[110],"codes":[112],"temperature":[113],"pressure":[115],"sensor":[116],"data":[117,158,164],"into":[118],"synthesis":[120],"transfer":[124],"from":[126],"source,":[129],"core,":[132],"sink,":[136],"environment.":[138],"With":[139],"this":[140],"form":[145],"patterns":[147],"that":[148,173],"can":[149],"be":[150],"easily":[151],"interpreted":[152],"by":[153],"operator,":[155],"operator's":[157],"search":[159],"time,":[160,162],"dwell":[161],"processing":[165],"workload":[166],"are":[167],"minimized,":[168],"enhancing":[170],"probability":[172,183],"will":[176],"make":[177],"correct":[178],"decisions":[179],"minimizing":[181],"errors.":[185]},"counts_by_year":[],"updated_date":"2026-09-22T06:50:58.402377","created_date":"2016-06-24T00:00:00"}
