{"id":"https://openalex.org/W2124369850","doi":"https://doi.org/10.1109/pcicon.2005.1524567","title":"Industrial Cybersecurity for Power System and Scada Networks","display_name":"Industrial Cybersecurity for Power System and Scada Networks","alternate_titles":[],"publication_year":2006,"publication_date":"2006-10-11","ids":{"openalex":"https://openalex.org/W2124369850","doi":"https://doi.org/10.1109/pcicon.2005.1524567","mag":"2124369850"},"language":"en","primary_location":{"id":"doi:10.1109/pcicon.2005.1524567","doi":"https://doi.org/10.1109/pcicon.2005.1524567","is_oa":false,"landing_page_url":"https://doi.org/10.1109/pcicon.2005.1524567","pdf_url":null,"source":{"id":"https://openalex.org/S4210220794","display_name":"Record of conference papers/Record of conference papers - Petroleum and Chemical Industry Conference","issn_l":"0090-3507","issn":["0090-3507","2161-8127"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["jufo-1","norway-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Record of Conference Papers Industry Applications Society 52nd Annual Petroleum and Chemical Industry Conference","raw_type":"proceedings-article"},"parent_works":[],"lineage":["https://openalex.org/W2124369850"],"child_works_count":0,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5048952041","display_name":"Adam Creery","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"A. Creery","raw_affiliation_strings":["Universal Dynamics Limited, Richmond, BC, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universal Dynamics Limited, Richmond, BC, Canada","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5066106846","display_name":"Eric James Byres","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I174167972","display_name":"British Columbia Institute of Technology","ror":"https://ror.org/01p65pg69","country_code":"CA","type":"education","lineage":["https://openalex.org/I174167972"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"E.J. Byres","raw_affiliation_strings":["BC Institute of Technology BCIT, Burnaby, BC, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"BC Institute of Technology BCIT, Burnaby, BC, Canada","institution_ids":["https://openalex.org/I174167972"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":5.1703,"has_fulltext":false,"cited_by_count":95,"citation_normalized_percentile":{"value":0.96402484,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":87,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"303","last_page":"309"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10734","display_name":"Information and Cyber Security","score":0.0005000000237487257,"subfield":{"id":"https://openalex.org/subfields/1710","display_name":"Information Systems"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10400","display_name":"Network Security and Intrusion Detection","score":0.00019999999494757503,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/industrial-cybersecurity","display_name":"industrial cybersecurity","score":0.9909999966621399},{"id":"https://openalex.org/keywords/power-system-networks","display_name":"power system networks","score":0.640999972820282},{"id":"https://openalex.org/keywords/scada-networks","display_name":"SCADA networks","score":0.8709999918937683},{"id":"https://openalex.org/keywords/networked-control-systems","display_name":"networked control systems","score":0.9760000109672546},{"id":"https://openalex.org/keywords/vulnerability-assessment","display_name":"vulnerability assessment","score":0.7459999918937683},{"id":"https://openalex.org/keywords/security-controls","display_name":"security countermeasures","score":0.8840000033378601},{"id":"https://openalex.org/keywords/legacy-systems","display_name":"legacy systems","score":0.7049999833106995},{"id":"https://openalex.org/keywords/industrial-automation","display_name":"industrial automation","score":0.43799999356269836}],"concepts":[{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.7399576902389526},{"id":"https://openalex.org/C113863187","wikidata":"https://www.wikidata.org/wiki/Q17498","display_name":"SCADA","level":2,"score":0.7306933403015137},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.616511344909668},{"id":"https://openalex.org/C112930515","wikidata":"https://www.wikidata.org/wiki/Q4389547","display_name":"Risk analysis (engineering)","level":1,"score":0.5462406277656555},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.5365560054779053},{"id":"https://openalex.org/C167063184","wikidata":"https://www.wikidata.org/wiki/Q1400839","display_name":"Vulnerability assessment","level":3,"score":0.5074934363365173},{"id":"https://openalex.org/C95713431","wikidata":"https://www.wikidata.org/wiki/Q631425","display_name":"Vulnerability (computing)","level":2,"score":0.5046924352645874},{"id":"https://openalex.org/C40071531","wikidata":"https://www.wikidata.org/wiki/Q2513962","display_name":"Industrial control system","level":3,"score":0.5002889633178711},{"id":"https://openalex.org/C29852176","wikidata":"https://www.wikidata.org/wiki/Q373338","display_name":"Critical infrastructure","level":2,"score":0.4891110062599182},{"id":"https://openalex.org/C172862783","wikidata":"https://www.wikidata.org/wiki/Q5165888","display_name":"Control system security","level":5,"score":0.470475971698761},{"id":"https://openalex.org/C2779777834","wikidata":"https://www.wikidata.org/wiki/Q4202277","display_name":"Enforcement","level":2,"score":0.43076273798942566},{"id":"https://openalex.org/C115901376","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automation","level":2,"score":0.42606550455093384},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.4145650565624237},{"id":"https://openalex.org/C172776598","wikidata":"https://www.wikidata.org/wiki/Q7943570","display_name":"Vulnerability management","level":4,"score":0.4140976071357727},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.4015427231788635},{"id":"https://openalex.org/C29983905","wikidata":"https://www.wikidata.org/wiki/Q7445066","display_name":"Security service","level":3,"score":0.2205541729927063},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2109551727771759},{"id":"https://openalex.org/C117110713","wikidata":"https://www.wikidata.org/wiki/Q3394676","display_name":"Network security policy","level":4,"score":0.2103213369846344},{"id":"https://openalex.org/C527648132","wikidata":"https://www.wikidata.org/wiki/Q189900","display_name":"Information security","level":2,"score":0.19953757524490356},{"id":"https://openalex.org/C144133560","wikidata":"https://www.wikidata.org/wiki/Q4830453","display_name":"Business","level":0,"score":0.17762145400047302},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.1456531584262848},{"id":"https://openalex.org/C542102704","wikidata":"https://www.wikidata.org/wiki/Q183257","display_name":"Psychotherapist","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C17744445","wikidata":"https://www.wikidata.org/wiki/Q36442","display_name":"Political science","level":0,"score":0.0},{"id":"https://openalex.org/C15744967","wikidata":"https://www.wikidata.org/wiki/Q9418","display_name":"Psychology","level":0,"score":0.0},{"id":"https://openalex.org/C137176749","wikidata":"https://www.wikidata.org/wiki/Q4105337","display_name":"Psychological resilience","level":2,"score":0.0},{"id":"https://openalex.org/C199539241","wikidata":"https://www.wikidata.org/wiki/Q7748","display_name":"Law","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/pcicon.2005.1524567","doi":"https://doi.org/10.1109/pcicon.2005.1524567","is_oa":false,"landing_page_url":"https://doi.org/10.1109/pcicon.2005.1524567","pdf_url":null,"source":{"id":"https://openalex.org/S4210220794","display_name":"Record of conference papers/Record of conference papers - Petroleum and Chemical Industry Conference","issn_l":"0090-3507","issn":["0090-3507","2161-8127"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["jufo-1","norway-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Record of Conference Papers Industry Applications Society 52nd Annual Petroleum and Chemical Industry Conference","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":1.0}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":8,"referenced_works":["https://openalex.org/W653086118","https://openalex.org/W1550189296","https://openalex.org/W1653851611","https://openalex.org/W2345292669","https://openalex.org/W3217808497","https://openalex.org/W4205472781","https://openalex.org/W4285719527","https://openalex.org/W7100533130"],"related_works":["https://openalex.org/W2086199236","https://openalex.org/W2252567165","https://openalex.org/W1987465543","https://openalex.org/W625616531","https://openalex.org/W2347304241","https://openalex.org/W2370736111","https://openalex.org/W7095262614","https://openalex.org/W3126291053","https://openalex.org/W2271608432","https://openalex.org/W2154705412"],"abstract_inverted_index":{"Many":[0],"automation":[1],"and":[2,22,25,31,47,56,66,94,107,127],"modernization":[3],"programs":[4],"are":[5,17,89,92,102],"now":[6],"employing":[7],"Intranet/Internet":[8],"technologies":[9],"in":[10,28,124],"industrial":[11],"control":[12,62,79],"strategies.":[13],"The":[14,69],"ensuing":[15],"systems":[16,63],"a":[18,73],"mixture":[19],"of":[20,33,60,76,129],"state-of-the-art":[21],"legacy":[23],"installations":[24],"create":[26],"challenges":[27],"the":[29,58,77,111,115,125,130],"implementation":[30],"enforcement":[32],"security":[34,126],"measures.":[35],"Control":[36],"system":[37],"intrusions":[38],"can":[39],"cause":[40],"environmental":[41],"damage,":[42],"safety":[43],"risks,":[44],"poor":[45],"quality":[46],"lost":[48],"production.":[49],"This":[50],"paper":[51],"presents":[52],"methods":[53],"to":[54,64,81,97,118],"determine":[55],"reduce":[57],"vulnerability":[59],"networked":[61],"unintended":[65],"malicious":[67],"intrusions.":[68],"procedure":[70],"for":[71],"conducting":[72],"thorough":[74],"assessment":[75,112],"process":[78],"networks":[80],"evaluate":[82],"these":[83,99],"risks":[84],"is":[85],"presented.":[86],"Security":[87],"issues":[88],"identified,":[90],"as":[91],"technical":[93],"procedural":[95],"countermeasures":[96],"mitigate":[98],"risks.":[100],"Examples":[101],"drawn":[103],"from":[104],"past":[105],"assessments":[106],"incidents.":[108],"Once":[109],"complete,":[110],"results":[113],"allow":[114],"network":[116],"designer":[117],"plan":[119],"infrastructure":[120],"expansion":[121],"with":[122],"confidence":[123],"reliability":[128],"network's":[131],"operation.":[132]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2124369850","counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2025,"cited_by_count":4},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":7},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":4},{"year":2019,"cited_by_count":3},{"year":2018,"cited_by_count":6},{"year":2017,"cited_by_count":7},{"year":2016,"cited_by_count":2},{"year":2015,"cited_by_count":5},{"year":2014,"cited_by_count":4},{"year":2013,"cited_by_count":10},{"year":2012,"cited_by_count":5}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-06-24T00:00:00"}
