{"id":"https://openalex.org/W2124167237","doi":"https://doi.org/10.1177/0957650912446547","title":"Performance characteristics of ejector expander transcritical CO 2 refrigeration cycle","display_name":"Performance characteristics of ejector expander transcritical CO 2 refrigeration cycle","publication_year":2012,"publication_date":"2012-05-09","ids":{"openalex":"https://openalex.org/W2124167237","doi":"https://doi.org/10.1177/0957650912446547","mag":"2124167237"},"language":"en","primary_location":{"id":"doi:10.1177/0957650912446547","doi":"https://doi.org/10.1177/0957650912446547","is_oa":false,"landing_page_url":"https://doi.org/10.1177/0957650912446547","pdf_url":null,"source":{"id":"https://openalex.org/S109525458","display_name":"Proceedings of the Institution of Mechanical Engineers Part A Journal of Power and Energy","issn_l":"0957-6509","issn":["0957-6509","2041-2967"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","jufo-1","norway-1","poland-70","russia-white-list-2"],"host_organization":"https://openalex.org/P4310320017","host_organization_name":"SAGE Publishing","host_organization_lineage":["https://openalex.org/P4310320017"],"host_organization_lineage_names":["SAGE Publishing"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5037156423","display_name":"H. K\u00fcr\u015fad Ersoy","orcid":"https://orcid.org/0000-0001-8588-296X","observed_orcids":["https://orcid.org/0000-0001-8588-296X"]},"institutions":[{"id":"https://openalex.org/I137996928","display_name":"Sel\u00e7uk University","ror":"https://ror.org/045hgzm75","country_code":"TR","type":"education","lineage":["https://openalex.org/I137996928"]}],"countries":["TR"],"is_corresponding":true,"raw_author_name":"H Kursad Ersoy","raw_affiliation_strings":["Department of Mechanical Engineering, Selcuk University, Turkey"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Mechanical Engineering, Selcuk University, Turkey","institution_ids":["https://openalex.org/I137996928"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5013607985","display_name":"Nagihan Bilir Sa\u011f","orcid":"https://orcid.org/0000-0001-8410-0268","observed_orcids":["https://orcid.org/0000-0001-8410-0268"]},"institutions":[{"id":"https://openalex.org/I137996928","display_name":"Sel\u00e7uk University","ror":"https://ror.org/045hgzm75","country_code":"TR","type":"education","lineage":["https://openalex.org/I137996928"]}],"countries":["TR"],"is_corresponding":false,"raw_author_name":"Nagihan Bilir","raw_affiliation_strings":["Department of Mechanical Engineering, Selcuk University, Turkey"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Mechanical Engineering, Selcuk University, Turkey","institution_ids":["https://openalex.org/I137996928"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5037156423"],"corresponding_institution_ids":["https://openalex.org/I137996928"],"apc_list":{"value":4150,"currency":"USD","value_usd":4150},"apc_paid":null,"fwci":3.1529,"has_fulltext":false,"cited_by_count":34,"citation_normalized_percentile":{"value":0.89640161,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":98},"biblio":{"volume":"226","issue":"5","first_page":"623","last_page":"635"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.9868000149726868,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.9868000149726868,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10568","display_name":"Thermodynamic and Exergetic Analyses of Power and Cooling Systems","score":0.011900000274181366,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12139","display_name":"Advanced Thermodynamic Systems and Engines","score":0.00039999998989515007,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/transcritical-co2-refrigeration-cycle","display_name":"transcritical CO2 refrigeration cycle","score":0.9660000205039978},{"id":"https://openalex.org/keywords/ejector-refrigeration","display_name":"ejector refrigeration","score":0.6129999756813049},{"id":"https://openalex.org/keywords/coefficient-of-performance","display_name":"coefficient of performance","score":0.6869999766349792},{"id":"https://openalex.org/keywords/exergy-efficiency","display_name":"exergy efficiency","score":0.996999979019165},{"id":"https://openalex.org/keywords/irreversibility","display_name":"irreversibility","score":0.7369999885559082},{"id":"https://openalex.org/keywords/gas-cooler-pressure","display_name":"gas cooler pressure","score":0.6990000009536743}],"concepts":[{"id":"https://openalex.org/C135186712","wikidata":"https://www.wikidata.org/wiki/Q425705","display_name":"Injector","level":2,"score":0.824329674243927},{"id":"https://openalex.org/C69907114","wikidata":"https://www.wikidata.org/wiki/Q747713","display_name":"Refrigeration","level":2,"score":0.7457116842269897},{"id":"https://openalex.org/C91311341","wikidata":"https://www.wikidata.org/wiki/Q1764892","display_name":"Evaporator","level":3,"score":0.7220755815505981},{"id":"https://openalex.org/C75825664","wikidata":"https://www.wikidata.org/wiki/Q1155000","display_name":"Transcritical cycle","level":4,"score":0.6692071557044983},{"id":"https://openalex.org/C83119724","wikidata":"https://www.wikidata.org/wiki/Q3070886","display_name":"Exergy efficiency","level":3,"score":0.6629733443260193},{"id":"https://openalex.org/C164915370","wikidata":"https://www.wikidata.org/wiki/Q5167494","display_name":"Cooling capacity","level":2,"score":0.6220676898956299},{"id":"https://openalex.org/C56200935","wikidata":"https://www.wikidata.org/wiki/Q250840","display_name":"Nozzle","level":2,"score":0.6031598448753357},{"id":"https://openalex.org/C13119800","wikidata":"https://www.wikidata.org/wiki/Q902090","display_name":"Coefficient of performance","level":4,"score":0.5847843885421753},{"id":"https://openalex.org/C96261405","wikidata":"https://www.wikidata.org/wiki/Q7113544","display_name":"Overall pressure ratio","level":3,"score":0.5740731954574585},{"id":"https://openalex.org/C114088122","wikidata":"https://www.wikidata.org/wiki/Q1261069","display_name":"Pressure drop","level":2,"score":0.547999382019043},{"id":"https://openalex.org/C113146524","wikidata":"https://www.wikidata.org/wiki/Q663290","display_name":"Exergy","level":2,"score":0.5221788883209229},{"id":"https://openalex.org/C141713623","wikidata":"https://www.wikidata.org/wiki/Q1452596","display_name":"Heat pump and refrigeration cycle","level":4,"score":0.5011570453643799},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.49125736951828003},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.47868186235427856},{"id":"https://openalex.org/C2779301550","wikidata":"https://www.wikidata.org/wiki/Q217236","display_name":"Working fluid","level":2,"score":0.46658092737197876},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.3918887972831726},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.38912254571914673},{"id":"https://openalex.org/C116915560","wikidata":"https://www.wikidata.org/wiki/Q83504","display_name":"Nuclear engineering","level":1,"score":0.3788113594055176},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.2380995750427246},{"id":"https://openalex.org/C131097465","wikidata":"https://www.wikidata.org/wiki/Q178898","display_name":"Gas compressor","level":2,"score":0.2293347418308258},{"id":"https://openalex.org/C199499590","wikidata":"https://www.wikidata.org/wiki/Q266790","display_name":"Refrigerant","level":3,"score":0.21384850144386292},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.18426242470741272},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1177/0957650912446547","doi":"https://doi.org/10.1177/0957650912446547","is_oa":false,"landing_page_url":"https://doi.org/10.1177/0957650912446547","pdf_url":null,"source":{"id":"https://openalex.org/S109525458","display_name":"Proceedings of the Institution of Mechanical Engineers Part A Journal of Power and Energy","issn_l":"0957-6509","issn":["0957-6509","2041-2967"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-c","jufo-1","norway-1","poland-70","russia-white-list-2"],"host_organization":"https://openalex.org/P4310320017","host_organization_name":"SAGE Publishing","host_organization_lineage":["https://openalex.org/P4310320017"],"host_organization_lineage_names":["SAGE Publishing"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.5690000057220459,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"},{"score":0.5351999998092651,"display_name":"Climate action","id":"https://metadata.un.org/sdg/13"}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320332178","display_name":"National Institute of Standards and Technology","ror":"https://ror.org/05xpvk416"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":23,"referenced_works":["https://openalex.org/W1492715186","https://openalex.org/W1521550204","https://openalex.org/W1967878960","https://openalex.org/W1969283876","https://openalex.org/W1972985890","https://openalex.org/W1977640614","https://openalex.org/W1995661493","https://openalex.org/W2001499479","https://openalex.org/W2019016925","https://openalex.org/W2025214840","https://openalex.org/W2026060382","https://openalex.org/W2031616607","https://openalex.org/W2032027318","https://openalex.org/W2033976726","https://openalex.org/W2040065952","https://openalex.org/W2046472663","https://openalex.org/W2050858653","https://openalex.org/W2051256013","https://openalex.org/W2062826583","https://openalex.org/W2075077695","https://openalex.org/W2093966337","https://openalex.org/W2148666332","https://openalex.org/W2307344632"],"related_works":["https://openalex.org/W2046472663","https://openalex.org/W2148666332","https://openalex.org/W3026372353","https://openalex.org/W107300430","https://openalex.org/W2060898897","https://openalex.org/W2323305355","https://openalex.org/W4412366821","https://openalex.org/W2085455979","https://openalex.org/W7066003818","https://openalex.org/W2025926141"],"abstract_inverted_index":{"The":[0,38,83,149,168],"effects":[1],"on":[2,92],"the":[3,6,17,35,49,61,93,112,118,128,154,159,201,205,213],"performance":[4,42,138],"of":[5,40,98,137,179,186,191,197,204,212],"basic":[7,214],"CO":[8],"2":[9],"refrigeration":[10,156],"cycle":[11,144,157],"when":[12,158],"using":[13,79],"an":[14,109,131,166],"ejector":[15,29,36,62,94,110,129,160,206],"as":[16,130,165],"expander":[18,132,217],"to":[19,107,116,153],"recover":[20],"expansion":[21],"work":[22],"were":[23,65,77],"investigated.":[24],"A":[25],"two-phase":[26],"constant":[27],"area":[28,63,95,114],"flow":[30],"model":[31],"was":[32,208],"used":[33,164],"in":[34],"analysis.":[37],"coefficient":[39,97,136],"cooling":[41,99,195],"and":[43,57,70,101,122,139,194,215,221],"gas":[44,71,176,182],"cooler":[45,72,177,183],"pressure":[46,55,86,120,178],"that":[47,126,172],"yielded":[48],"maximum":[50,123],"exergy":[51,102,140],"efficiency,":[52],"suction":[53,84],"nozzle":[54,85],"drop,":[56],"optimum":[58,113,119],"values":[59],"for":[60,67],"ratio":[64,115],"determined":[66],"various":[68],"evaporator":[69,189],"outlet":[73,184],"temperatures.":[74],"Parametric":[75],"studies":[76],"performed":[78],"engineering":[80],"equation":[81],"solver.":[82],"drop":[87,121],"had":[88],"a":[89,175],"significant":[90],"effect":[91],"ratio,":[96],"performance,":[100],"efficiency.":[103],"It":[104],"is":[105],"necessary":[106],"design":[108],"with":[111],"achieve":[117],"performance.":[124],"Cycle":[125],"use":[127],"always":[133],"has":[134],"higher":[135],"efficiency":[141],"than":[142,210],"conventional":[143],"under":[145,174],"any":[146],"operating":[147],"condition.":[148],"irreversibility":[150,203],"decreases":[151],"compared":[152],"classic":[155],"or":[161],"turbine":[162,216],"are":[163],"expander.":[167],"analysis":[169],"results":[170],"showed":[171],"\u2013":[173,200],"9.5":[180],"MPa,":[181],"temperature":[185,190],"40":[187],"\u00b0C,":[188,193],"5":[192],"capacity":[196],"3.5":[198],"kW":[199],"total":[202],"system":[207],"lower":[209],"those":[211],"systems":[218],"by":[219],"39.1%":[220],"5.46%,":[222],"respectively.":[223]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":3},{"year":2023,"cited_by_count":3},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":3},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":3},{"year":2018,"cited_by_count":2},{"year":2017,"cited_by_count":5},{"year":2016,"cited_by_count":3},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":3},{"year":2012,"cited_by_count":1}],"updated_date":"2026-11-10T11:39:43.021295","created_date":"2016-06-24T00:00:00"}
