{"id":"https://openalex.org/W2118780845","doi":"https://doi.org/10.1109/cpe.2011.5942212","title":"Operation of photovoltaic power systems with energy storage","display_name":"Operation of photovoltaic power systems with energy storage","publication_year":2011,"publication_date":"2011-06-01","ids":{"openalex":"https://openalex.org/W2118780845","doi":"https://doi.org/10.1109/cpe.2011.5942212","mag":"2118780845"},"language":"en","primary_location":{"id":"doi:10.1109/cpe.2011.5942212","doi":"https://doi.org/10.1109/cpe.2011.5942212","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cpe.2011.5942212","pdf_url":null,"source":{"id":"https://openalex.org/S4306422608","display_name":"IEEE International Conference on Compatibility, Power Electronics and Power Engineering","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 7th International Conference-Workshop Compatibility and Power Electronics (CPE)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5109250609","display_name":"Bernard J. Szymanski","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Bernard J. Szymanski","raw_affiliation_strings":["Electronics and Automation Center, ELPOL, Radom, Poland","ELPOL, Electronics and Automation Center"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electronics and Automation Center, ELPOL, Radom, Poland","institution_ids":[]},{"raw_affiliation_string":"ELPOL, Electronics and Automation Center","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5014916512","display_name":"Kamil Kompa","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I108403487","display_name":"Warsaw University of Technology","ror":"https://ror.org/00y0xnp53","country_code":"PL","type":"education","lineage":["https://openalex.org/I108403487"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Kamil Kompa","raw_affiliation_strings":["Institute of Electrical Power Engineering, Warsaw University of Technology, Warsaw, Poland","Institute of Information Technology, Warsaw University of Technology, Nowowiejska 15/19, 00-665 Warsaw"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Electrical Power Engineering, Warsaw University of Technology, Warsaw, Poland","institution_ids":["https://openalex.org/I108403487"]},{"raw_affiliation_string":"Institute of Information Technology, Warsaw University of Technology, Nowowiejska 15/19, 00-665 Warsaw","institution_ids":["https://openalex.org/I108403487"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5026862856","display_name":"\u0141ukasz Ros\u0142aniec","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I108403487","display_name":"Warsaw University of Technology","ror":"https://ror.org/00y0xnp53","country_code":"PL","type":"education","lineage":["https://openalex.org/I108403487"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Lukasz Roslaniec","raw_affiliation_strings":["Institute of Electrical Power Engineering, Warsaw University of Technology, Warsaw, Poland","Institute of Electrical Power Engineering, Warsaw University of Technology, Plac Politechniki 1, 00-661 Warsaw"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Electrical Power Engineering, Warsaw University of Technology, Warsaw, Poland","institution_ids":["https://openalex.org/I108403487"]},{"raw_affiliation_string":"Institute of Electrical Power Engineering, Warsaw University of Technology, Plac Politechniki 1, 00-661 Warsaw","institution_ids":["https://openalex.org/I108403487"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5006325822","display_name":"Antoni Dmowski","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I108403487","display_name":"Warsaw University of Technology","ror":"https://ror.org/00y0xnp53","country_code":"PL","type":"education","lineage":["https://openalex.org/I108403487"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Antoni Dmowski","raw_affiliation_strings":["Institute of Information Technology, Warsaw University of Technology, Warsaw, Poland","Institute of Electrical Power Engineering, Warsaw University of Technology, Plac Politechniki 1, 00-661 Warsaw"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Information Technology, Warsaw University of Technology, Warsaw, Poland","institution_ids":["https://openalex.org/I108403487"]},{"raw_affiliation_string":"Institute of Electrical Power Engineering, Warsaw University of Technology, Plac Politechniki 1, 00-661 Warsaw","institution_ids":["https://openalex.org/I108403487"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5069506820","display_name":"Jerzy Ryszard Szymanski","orcid":"https://orcid.org/0000-0002-9493-8424","observed_orcids":["https://orcid.org/0000-0002-9493-8424"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Jerzy Szymanski","raw_affiliation_strings":["Faculty of Transport and Electrical Engineering, Radom University of Technology, Radom, Poland","Faculty of Transport and Electrical Engineering, Radom University of Technology, Malczewskiego 29, 26-600 Radom"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Faculty of Transport and Electrical Engineering, Radom University of Technology, Radom, Poland","institution_ids":[]},{"raw_affiliation_string":"Faculty of Transport and Electrical Engineering, Radom University of Technology, Malczewskiego 29, 26-600 Radom","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":5.1806,"has_fulltext":false,"cited_by_count":14,"citation_normalized_percentile":{"value":0.95218353,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":88,"max":98},"biblio":{"volume":null,"issue":null,"first_page":"86","last_page":"91"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10468","display_name":"Photovoltaic System Optimization Techniques","score":0.6190999746322632,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10468","display_name":"Photovoltaic System Optimization Techniques","score":0.6190999746322632,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.28130000829696655,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.05620000138878822,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/photovoltaic-systems","display_name":"photovoltaic systems","score":0.9860000014305115},{"id":"https://openalex.org/keywords/energy-storage","display_name":"energy storage","score":0.9670000076293945},{"id":"https://openalex.org/keywords/electrochemical-batteries","display_name":"electrochemical batteries","score":0.9049999713897705},{"id":"https://openalex.org/keywords/galvanic-isolation","display_name":"galvanic isolation","score":0.8100000023841858},{"id":"https://openalex.org/keywords/soft-switching","display_name":"soft switching","score":0.8159999847412109},{"id":"https://openalex.org/keywords/resonant-converter","display_name":"resonant converter","score":0.9520000219345093},{"id":"https://openalex.org/keywords/switching-losses","display_name":"switching losses","score":0.7799999713897705},{"id":"https://openalex.org/keywords/grid-connected-inverter","display_name":"grid-connected inverter","score":0.7870000004768372},{"id":"https://openalex.org/keywords/renewable-energy-intermittency","display_name":"renewable energy intermittency","score":0.7440000176429749},{"id":"https://openalex.org/keywords/power-system-stability","display_name":"power system stability","score":0.7260000109672546}],"concepts":[{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.7057404518127441},{"id":"https://openalex.org/C36139824","wikidata":"https://www.wikidata.org/wiki/Q1052007","display_name":"Maximum power point tracking","level":4,"score":0.6790577173233032},{"id":"https://openalex.org/C195697387","wikidata":"https://www.wikidata.org/wiki/Q5608561","display_name":"Grid-connected photovoltaic power system","level":5,"score":0.5821978449821472},{"id":"https://openalex.org/C104708988","wikidata":"https://www.wikidata.org/wiki/Q1664450","display_name":"Stand-alone power system","level":4,"score":0.5811399221420288},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5687260031700134},{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.5640116930007935},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5404127836227417},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.5086292028427124},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.5043584108352661},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4971320927143097},{"id":"https://openalex.org/C145180747","wikidata":"https://www.wikidata.org/wiki/Q7236587","display_name":"Power optimizer","level":5,"score":0.469083696603775},{"id":"https://openalex.org/C141812795","wikidata":"https://www.wikidata.org/wiki/Q7236534","display_name":"Power module","level":3,"score":0.4477236866950989},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.4280977249145508},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.41514289379119873},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.3675105571746826},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3585096597671509},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.3212216794490814},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.11503595113754272},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.08700358867645264},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/cpe.2011.5942212","doi":"https://doi.org/10.1109/cpe.2011.5942212","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cpe.2011.5942212","pdf_url":null,"source":{"id":"https://openalex.org/S4306422608","display_name":"IEEE International Conference on Compatibility, Power Electronics and Power Engineering","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 7th International Conference-Workshop Compatibility and Power Electronics (CPE)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":1.0},{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.7207000255584717}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":7,"referenced_works":["https://openalex.org/W1558639116","https://openalex.org/W1594827275","https://openalex.org/W2067133092","https://openalex.org/W2144131108","https://openalex.org/W2287346103","https://openalex.org/W2498138719","https://openalex.org/W2946176762"],"related_works":["https://openalex.org/W2378275132","https://openalex.org/W2378610045","https://openalex.org/W2799149029","https://openalex.org/W3185024509","https://openalex.org/W4396932020","https://openalex.org/W2056943466","https://openalex.org/W3023141044","https://openalex.org/W4285800414","https://openalex.org/W2317639323","https://openalex.org/W1964774397"],"abstract_inverted_index":{"Photovoltaic":[0],"(PV)":[1],"power":[2,39,42,62,86,90,99,112,126],"systems":[3,91],"are":[4,64,105,107],"described":[5],"in":[6,29,88,101,109,130],"the":[7,20,33,38,58,68,74,82,85,124,131],"article.":[8,132],"Power":[9],"generated":[10],"from":[11],"renewable":[12],"energy":[13,21,48],"sources":[14],"is":[15,71,119,128],"not":[16],"stable":[17],"because":[18,56],"of":[19,37,57,84,123],"fluctuations":[22],"caused":[23],"mainly":[24],"by":[25,73],"atmospheric":[26],"conditions.":[27],"Therefore,":[28],"order":[30],"to":[31,93],"improve":[32],"parameters":[34],"and":[35],"stability":[36],"system,":[40],"PV":[41,61,89,111,116,125],"plants":[43,63],"should":[44],"cooperate":[45],"with":[46],"electrical":[47],"storage":[49],"system":[50,127],"such":[51,110],"as":[52],"electrochemical":[53],"batteries.":[54],"Moreover,":[55,114],"reason":[59],"that":[60],"often":[65],"located":[66],"on":[67],"terrain":[69],"which":[70,102,118],"accessible":[72],"man,":[75],"galvanic":[76],"isolation":[77],"may":[78],"be":[79,94],"obligatory.":[80],"Since":[81],"efficiency":[83],"conversion":[87],"has":[92],"maximized,":[95],"soft":[96],"switched":[97],"resonant":[98],"converters,":[100],"switching":[103],"losses":[104],"minimized,":[106],"utilized":[108],"systems.":[113],"grid-connected":[115],"inverter":[117],"a":[120],"crucial":[121],"element":[122],"presented":[129]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2014,"cited_by_count":4},{"year":2013,"cited_by_count":1},{"year":2012,"cited_by_count":1}],"updated_date":"2026-10-26T11:51:55.731654","created_date":"2016-06-24T00:00:00"}
