{"id":"https://openalex.org/W2117749765","doi":"https://doi.org/10.1109/sas.2006.1634270","title":"Measurement of respiratory rate with high-resolution accelerometer and emfit pressure sensor","display_name":"Measurement of respiratory rate with high-resolution accelerometer and emfit pressure sensor","alternate_titles":[],"publication_year":2006,"publication_date":"2006-05-25","ids":{"openalex":"https://openalex.org/W2117749765","doi":"https://doi.org/10.1109/sas.2006.1634270","mag":"2117749765"},"language":"en","primary_location":{"id":"doi:10.1109/sas.2006.1634270","doi":"https://doi.org/10.1109/sas.2006.1634270","is_oa":false,"landing_page_url":"https://doi.org/10.1109/sas.2006.1634270","pdf_url":null,"source":{"id":"https://openalex.org/S7407089080","display_name":"IEEE Sensors Applications Symposium (SAS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2006 IEEE Sensors Applications Symposium, 2006.","raw_type":"proceedings-article"},"parent_works":[],"lineage":["https://openalex.org/W2117749765"],"child_works_count":0,"pull_notice_works":[],"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5059960483","display_name":"Tuomas Reinvuo","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I98381234","display_name":"University of Oulu","ror":"https://ror.org/03yj89h83","country_code":"FI","type":"education","lineage":["https://openalex.org/I98381234"]}],"countries":["FI"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"T. Reinvuo","raw_affiliation_strings":["Department of Electrical and Information Engineering, University of Oulu, Oulu, Finland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Information Engineering, University of Oulu, Oulu, Finland","institution_ids":["https://openalex.org/I98381234"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5007304012","display_name":"Manne Hannula","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I98381234","display_name":"University of Oulu","ror":"https://ror.org/03yj89h83","country_code":"FI","type":"education","lineage":["https://openalex.org/I98381234"]}],"countries":["FI"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"M. Hannula","raw_affiliation_strings":["Department of Electrical and Information Engineering, University of Oulu, Oulu, Finland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Information Engineering, University of Oulu, Oulu, Finland","institution_ids":["https://openalex.org/I98381234"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5060922696","display_name":"Hannu S. S. Sorvoja","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I98381234","display_name":"University of Oulu","ror":"https://ror.org/03yj89h83","country_code":"FI","type":"education","lineage":["https://openalex.org/I98381234"]}],"countries":["FI"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"H. Sorvoja","raw_affiliation_strings":["Department of Electrical and Information Engineering, University of Oulu, Oulu, Finland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Information Engineering, University of Oulu, Oulu, Finland","institution_ids":["https://openalex.org/I98381234"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5109308060","display_name":"Esko Alasaarela","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I98381234","display_name":"University of Oulu","ror":"https://ror.org/03yj89h83","country_code":"FI","type":"education","lineage":["https://openalex.org/I98381234"]}],"countries":["FI"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"E. Alasaarela","raw_affiliation_strings":["Department of Electrical and Information Engineering, University of Oulu, Oulu, Finland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Information Engineering, University of Oulu, Oulu, Finland","institution_ids":["https://openalex.org/I98381234"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5024436386","display_name":"Risto A Myllyl\u00e4","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I98381234","display_name":"University of Oulu","ror":"https://ror.org/03yj89h83","country_code":"FI","type":"education","lineage":["https://openalex.org/I98381234"]}],"countries":["FI"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"R. Myllyla","raw_affiliation_strings":["Department of Electrical and Information Engineering, University of Oulu, Oulu, Finland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Information Engineering, University of Oulu, Oulu, Finland","institution_ids":["https://openalex.org/I98381234"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I98381234"],"apc_list":null,"apc_paid":null,"fwci":6.7726,"has_fulltext":false,"cited_by_count":132,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.96872223,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"192","last_page":"195"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11932","display_name":"Wireless Body Area Networks","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10338","display_name":"Advanced Sensor and Energy Harvesting Materials","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/respiratory-rate-measurement","display_name":"respiratory rate measurement","score":0.9800000190734863},{"id":"https://openalex.org/keywords/mems-accelerometer","display_name":"MEMS accelerometer","score":0.8299999833106995},{"id":"https://openalex.org/keywords/wearable-sensors","display_name":"wearable sensors","score":0.625},{"id":"https://openalex.org/keywords/smart-shirt","display_name":"smart shirt","score":0.6079999804496765},{"id":"https://openalex.org/keywords/sensor-reliability","display_name":"sensor reliability","score":0.546999990940094},{"id":"https://openalex.org/keywords/hospital-patient-monitoring","display_name":"hospital patient monitoring","score":0.5929999947547913}],"concepts":[{"id":"https://openalex.org/C89805583","wikidata":"https://www.wikidata.org/wiki/Q192940","display_name":"Accelerometer","level":2,"score":0.800575852394104},{"id":"https://openalex.org/C8213797","wikidata":"https://www.wikidata.org/wiki/Q754250","display_name":"Respiratory rate","level":4,"score":0.7912044525146484},{"id":"https://openalex.org/C2779358675","wikidata":"https://www.wikidata.org/wiki/Q3766250","display_name":"Respiratory monitoring","level":3,"score":0.6939811706542969},{"id":"https://openalex.org/C206755178","wikidata":"https://www.wikidata.org/wiki/Q1131271","display_name":"Capacitive sensing","level":2,"score":0.6445937752723694},{"id":"https://openalex.org/C37977207","wikidata":"https://www.wikidata.org/wiki/Q175561","display_name":"Microelectromechanical systems","level":2,"score":0.5703285336494446},{"id":"https://openalex.org/C41325743","wikidata":"https://www.wikidata.org/wiki/Q1261040","display_name":"Pressure sensor","level":2,"score":0.5143188238143921},{"id":"https://openalex.org/C2777953023","wikidata":"https://www.wikidata.org/wiki/Q1073121","display_name":"Heart rate","level":3,"score":0.4723806381225586},{"id":"https://openalex.org/C158488048","wikidata":"https://www.wikidata.org/wiki/Q483400","display_name":"Gyroscope","level":2,"score":0.45796895027160645},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.4193381667137146},{"id":"https://openalex.org/C175079658","wikidata":"https://www.wikidata.org/wiki/Q7312165","display_name":"Remote patient monitoring","level":2,"score":0.41685253381729126},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.41660889983177185},{"id":"https://openalex.org/C534529494","wikidata":"https://www.wikidata.org/wiki/Q7891","display_name":"Respiratory system","level":2,"score":0.3747352957725525},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.3649773597717285},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.34571510553359985},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.24957439303398132},{"id":"https://openalex.org/C84393581","wikidata":"https://www.wikidata.org/wiki/Q82642","display_name":"Blood pressure","level":2,"score":0.20181307196617126},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.20019596815109253},{"id":"https://openalex.org/C146978453","wikidata":"https://www.wikidata.org/wiki/Q3798668","display_name":"Aerospace engineering","level":1,"score":0.11512672901153564},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.09347358345985413},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.0915377140045166},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0840897262096405},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.06498557329177856},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/sas.2006.1634270","doi":"https://doi.org/10.1109/sas.2006.1634270","is_oa":false,"landing_page_url":"https://doi.org/10.1109/sas.2006.1634270","pdf_url":null,"source":{"id":"https://openalex.org/S7407089080","display_name":"IEEE Sensors Applications Symposium (SAS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2006 IEEE Sensors Applications Symposium, 2006.","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.9391000270843506,"display_name":"Good health and well-being","id":"https://metadata.un.org/sdg/3"}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320321855","display_name":"Tekes","ror":"https://ror.org/02ag8cq23"},{"id":"https://openalex.org/F4320330138","display_name":"Oulun Yliopistollinen Sairaala","ror":"https://ror.org/045ney286"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W1602472400","https://openalex.org/W1605535587","https://openalex.org/W1964562600","https://openalex.org/W2044431542","https://openalex.org/W2084770099","https://openalex.org/W2088899147","https://openalex.org/W2120729651","https://openalex.org/W2160182886","https://openalex.org/W2345135260","https://openalex.org/W2532566850","https://openalex.org/W2542000969","https://openalex.org/W2601918726","https://openalex.org/W6735651947"],"related_works":["https://openalex.org/W4388283272","https://openalex.org/W7015055541","https://openalex.org/W2020624939","https://openalex.org/W7127938828","https://openalex.org/W2772523043","https://openalex.org/W4400860769","https://openalex.org/W7043006922","https://openalex.org/W1982090044","https://openalex.org/W2739371599","https://openalex.org/W2114950466"],"abstract_inverted_index":{"Respiratory":[0],"rate":[1,30,46,64,98],"is":[2,130],"an":[3,77],"essential":[4],"parameter":[5],"in":[6,17,57],"the":[7,36,100,103,110,117,121,124,128],"clinical":[8],"monitoring":[9],"of":[10,38,41,102,109,123],"hospital":[11],"patients.":[12],"It":[13],"can":[14],"be":[15],"measured":[16],"various":[18],"ways,":[19],"such":[20],"as":[21],"by":[22],"recording":[23],"chest":[24,129],"movements,":[25],"breathing":[26],"flow":[27],"or":[28],"heart":[29],"variations.":[31],"Current":[32],"sensor":[33,68,125],"technology":[34],"allows":[35],"development":[37],"new":[39],"kinds":[40],"convenient":[42],"and":[43,76],"portable":[44],"respiratory":[45,63,97],"recorders,":[47],"including":[48],"smart":[49],"shirts,":[50],"which":[51],"enable":[52],"more":[53],"efficient":[54],"healthcare":[55],"processes":[56],"hospitals.":[58],"This":[59],"study":[60],"carried":[61],"out":[62],"measurements":[65],"using":[66],"a":[67,71],"belt":[69],"with":[70],"high-resolution":[72],"accelerometer":[73],"(capacitive":[74],"MEMS)":[75],"EMFit":[78,111],"(electret":[79],"film)":[80],"pressure":[81],"sensor.":[82],"Results":[83],"obtained":[84],"from":[85],"tests":[86],"on":[87,127],"10":[88],"subjects":[89],"showed":[90,119],"that":[91,108,120],"both":[92],"sensors":[93],"are":[94],"feasible":[95],"for":[96],"measurement;":[99],"reliability":[101],"MEMS":[104],"was":[105,112],"90%,":[106],"while":[107],"90-":[113],"100%.":[114],"In":[115],"addition,":[116],"results":[118],"location":[122],"module":[126],"important.":[131]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2117749765","counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":4},{"year":2024,"cited_by_count":9},{"year":2023,"cited_by_count":7},{"year":2022,"cited_by_count":13},{"year":2021,"cited_by_count":9},{"year":2020,"cited_by_count":17},{"year":2019,"cited_by_count":10},{"year":2018,"cited_by_count":8},{"year":2017,"cited_by_count":5},{"year":2016,"cited_by_count":6},{"year":2015,"cited_by_count":7},{"year":2014,"cited_by_count":4},{"year":2013,"cited_by_count":6},{"year":2012,"cited_by_count":7}],"updated_date":"2026-11-22T12:46:00.618207","created_date":"2016-06-24T00:00:00"}
