{"id":"https://openalex.org/W2109968622","doi":"https://doi.org/10.1080/19443994.2012.692041","title":"Experimental validation of thermal model of hybrid photovoltaic thermal (HPVT) double slope active solar still","display_name":"Experimental validation of thermal model of hybrid photovoltaic thermal (HPVT) double slope active solar still","publication_year":2012,"publication_date":"2012-05-16","ids":{"openalex":"https://openalex.org/W2109968622","doi":"https://doi.org/10.1080/19443994.2012.692041","mag":"2109968622"},"language":"en","primary_location":{"id":"doi:10.1080/19443994.2012.692041","doi":"https://doi.org/10.1080/19443994.2012.692041","is_oa":true,"landing_page_url":"https://doi.org/10.1080/19443994.2012.692041","pdf_url":null,"source":{"id":"https://openalex.org/S124203677","display_name":"Desalination and Water Treatment","issn_l":"1944-3986","issn":["1944-3986","1944-3994"],"is_oa":false,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-d","jufo-1","norway-1","poland-100","vabb-shw"],"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["Taylor & Francis","Informa"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Desalination and Water Treatment","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https://doi.org/10.1080/19443994.2012.692041","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Gajendra Singh","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Gajendra Singh","raw_affiliation_strings":["Department of Electrical Engineering, Krishna Institute of Engineering and Technology, Meerut Road, Ghaziabad, Uttar Pradesh, 201206, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Krishna Institute of Engineering and Technology, Meerut Road, Ghaziabad, Uttar Pradesh, 201206, India","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5081547265","display_name":"Vijay Kumar Dwivedi","orcid":"https://orcid.org/0000-0003-2703-6073","observed_orcids":["https://orcid.org/0000-0003-2703-6073"]},"institutions":[{"id":"https://openalex.org/I163072128","display_name":"Galgotias College of Engineering & Technology","ror":"https://ror.org/04a85ht85","country_code":"IN","type":"education","lineage":["https://openalex.org/I163072128"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"V.K. Dwivedi","raw_affiliation_strings":["Department of Mechanical Engineering, Galgotias College of Engineering and Technology, 1, Knowledge Park-II, Greater Noida, Uttar Pradesh-201306, India Phone: Tel. +91 9953001761 Fax: Tel. +91 9953001761"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Mechanical Engineering, Galgotias College of Engineering and Technology, 1, Knowledge Park-II, Greater Noida, Uttar Pradesh-201306, India Phone: Tel. +91 9953001761 Fax: Tel. +91 9953001761","institution_ids":["https://openalex.org/I163072128"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5027614817","display_name":"J.K. Yadav","orcid":"https://orcid.org/0000-0001-7508-1827","observed_orcids":["https://orcid.org/0000-0001-7508-1827"]},"institutions":[{"id":"https://openalex.org/I163072128","display_name":"Galgotias College of Engineering & Technology","ror":"https://ror.org/04a85ht85","country_code":"IN","type":"education","lineage":["https://openalex.org/I163072128"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"J.K. Yadav","raw_affiliation_strings":["Department of Mechanical Engineering, Galgotias College of Engineering and Technology, 1, Knowledge Park-II, Greater Noida, Uttar Pradesh-201306, India Phone: Tel. +91 9953001761 Fax: Tel. +91 9953001761"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Mechanical Engineering, Galgotias College of Engineering and Technology, 1, Knowledge Park-II, Greater Noida, Uttar Pradesh-201306, India Phone: Tel. +91 9953001761 Fax: Tel. +91 9953001761","institution_ids":["https://openalex.org/I163072128"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5111487931","display_name":"G.N. Tiwari","orcid":"https://orcid.org/0000-0001-5551-8606","observed_orcids":["https://orcid.org/0000-0001-5551-8606"]},"institutions":[{"id":"https://openalex.org/I68891433","display_name":"Indian Institute of Technology Delhi","ror":"https://ror.org/049tgcd06","country_code":"IN","type":"education","lineage":["https://openalex.org/I68891433"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"G.N. Tiwari","raw_affiliation_strings":["Centre for Energy Studies, Indian Institute of Technology, Delhi, Hauz Khas, New Delhi-110016, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Centre for Energy Studies, Indian Institute of Technology, Delhi, Hauz Khas, New Delhi-110016, India","institution_ids":["https://openalex.org/I68891433"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5081547265"],"corresponding_institution_ids":["https://openalex.org/I163072128"],"apc_list":{"value":1000,"currency":"USD","value_usd":1000},"apc_paid":{"value":1000,"currency":"USD","value_usd":1000},"fwci":0.2694,"has_fulltext":false,"cited_by_count":12,"citation_normalized_percentile":{"value":0.63406064,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":"45","issue":"1-3","first_page":"182","last_page":"190"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12008","display_name":"Solar-Powered Water Purification Methods","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12008","display_name":"Solar-Powered Water Purification Methods","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10905","display_name":"Solar Thermal and Photovoltaic Systems","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11774","display_name":"Adsorption and Cooling Systems","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hybrid-photovoltaic-thermal-collector","display_name":"hybrid photovoltaic-thermal collectors","score":0.8889999985694885},{"id":"https://openalex.org/keywords/double-slope-solar-still","display_name":"double slope solar still","score":0.8730000257492065},{"id":"https://openalex.org/keywords/active-solar-still","display_name":"active solar still","score":0.9010000228881836},{"id":"https://openalex.org/keywords/thermal-modeling","display_name":"thermal modeling","score":0.8240000009536743},{"id":"https://openalex.org/keywords/flat-plate-solar-collector","display_name":"flat plate solar collector","score":0.7020000219345093},{"id":"https://openalex.org/keywords/distillation","display_name":"distillation","score":0.5550000071525574},{"id":"https://openalex.org/keywords/energy-balance-equation","display_name":"energy balance equation","score":0.7210000157356262},{"id":"https://openalex.org/keywords/water-temperature","display_name":"water temperature","score":0.7409999966621399},{"id":"https://openalex.org/keywords/solar-distillation","display_name":"solar distillation","score":0.4699999988079071}],"concepts":[{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.7234962582588196},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.7021665573120117},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.5524548292160034},{"id":"https://openalex.org/C202112998","wikidata":"https://www.wikidata.org/wiki/Q3362339","display_name":"Photovoltaic thermal hybrid solar collector","level":3,"score":0.43225225806236267},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.41091302037239075},{"id":"https://openalex.org/C61696701","wikidata":"https://www.wikidata.org/wiki/Q770766","display_name":"Engineering physics","level":1,"score":0.3485323190689087},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.232588529586792},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.18948593735694885},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.16793251037597656},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.06569790840148926}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1080/19443994.2012.692041","doi":"https://doi.org/10.1080/19443994.2012.692041","is_oa":true,"landing_page_url":"https://doi.org/10.1080/19443994.2012.692041","pdf_url":null,"source":{"id":"https://openalex.org/S124203677","display_name":"Desalination and Water Treatment","issn_l":"1944-3986","issn":["1944-3986","1944-3994"],"is_oa":false,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-d","jufo-1","norway-1","poland-100","vabb-shw"],"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["Taylor & Francis","Informa"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Desalination and Water Treatment","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.1080/19443994.2012.692041","doi":"https://doi.org/10.1080/19443994.2012.692041","is_oa":true,"landing_page_url":"https://doi.org/10.1080/19443994.2012.692041","pdf_url":null,"source":{"id":"https://openalex.org/S124203677","display_name":"Desalination and Water Treatment","issn_l":"1944-3986","issn":["1944-3986","1944-3994"],"is_oa":false,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-d","jufo-1","norway-1","poland-100","vabb-shw"],"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["Taylor & Francis","Informa"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Desalination and Water Treatment","raw_type":"journal-article"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.9853000044822693}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W1963617954","https://openalex.org/W1968031518","https://openalex.org/W1968328410","https://openalex.org/W1985124309","https://openalex.org/W1989066886","https://openalex.org/W2013389371","https://openalex.org/W2036956950","https://openalex.org/W2047584903","https://openalex.org/W2058708409","https://openalex.org/W2069141066","https://openalex.org/W2090473327","https://openalex.org/W2091425252","https://openalex.org/W2091926121","https://openalex.org/W2093828253"],"related_works":["https://openalex.org/W1985124309","https://openalex.org/W2033916676","https://openalex.org/W2277134273","https://openalex.org/W2950442282","https://openalex.org/W3196542137","https://openalex.org/W2051591209","https://openalex.org/W2064050180","https://openalex.org/W2082133566","https://openalex.org/W2081364965","https://openalex.org/W2767906965"],"abstract_inverted_index":{"A":[0],"HPVT":[1,21],"double":[2,22],"slope":[3,23],"active":[4,24],"solar":[5,25,38],"still":[6,26,39],"was":[7],"designed":[8],"and":[9,50,62,95],"fabricated":[10],"to":[11,34,105],"study":[12],"their":[13],"performance.":[14],"In":[15],"this":[16],"paper":[17],"thermal":[18,73],"modeling":[19],"of":[20,37,60,68,75,100],"with":[27,81,98],"two":[28],"fl":[29],"at":[30],"plate":[31],"collectors":[32],"connected":[33],"the":[35,66],"basin":[36],"has":[40,78,85],"been":[41,55,79,86],"carried":[42],"out.":[43],"Analytical":[44],"expressions":[45],"for":[46],"yield,":[47],"water":[48],"temperature":[49,53],"condensing":[51],"cover":[52],"have":[54],"derived":[56],"as":[57],"a":[58],"function":[59],"climatic":[61],"design":[63],"parameters":[64],"on":[65],"basis":[67],"energy":[69],"balance":[70],"equations.":[71],"The":[72],"model":[74],"distillation":[76],"system":[77],"validated":[80],"experimental":[82,96],"data.":[83],"It":[84],"established":[87],"that":[88],"there":[89],"are":[90],"close":[91],"agreement":[92],"between":[93],"theoretical":[94],"results":[97],"coefficient":[99],"correlation":[101],"varying":[102],"from":[103],"0.872":[104],"0.965.":[106]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2023,"cited_by_count":2},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":3},{"year":2017,"cited_by_count":2},{"year":2015,"cited_by_count":1},{"year":2013,"cited_by_count":1}],"updated_date":"2026-10-30T12:39:25.321706","created_date":"2016-06-24T00:00:00"}
