{"id":"https://openalex.org/W2108946166","doi":"https://doi.org/10.1109/cpre.2009.4982529","title":"Enhanced overcurrent algorithm for performance under CT saturation in industrial applications","display_name":"Enhanced overcurrent algorithm for performance under CT saturation in industrial applications","publication_year":2009,"publication_date":"2009-03-01","ids":{"openalex":"https://openalex.org/W2108946166","doi":"https://doi.org/10.1109/cpre.2009.4982529","mag":"2108946166"},"language":"en","primary_location":{"id":"doi:10.1109/cpre.2009.4982529","doi":"https://doi.org/10.1109/cpre.2009.4982529","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cpre.2009.4982529","pdf_url":null,"source":{"id":"https://openalex.org/S4306418003","display_name":"Conference for Protective Relay Engineers","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2009 62nd Annual Conference for Protective Relay Engineers","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5055047406","display_name":"Vijay Muthukrishnan","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I2801941315","display_name":"General Electric (Canada)","ror":"https://ror.org/00rey4c89","country_code":"CA","type":"company","lineage":["https://openalex.org/I1332737386","https://openalex.org/I2801941315"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Vijay Muthukrishnan","raw_affiliation_strings":["GE Multilin, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"GE Multilin, Canada","institution_ids":["https://openalex.org/I2801941315"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5011700489","display_name":"Lubomir Sevov","orcid":"https://orcid.org/0000-0003-4911-9945","observed_orcids":["https://orcid.org/0000-0003-4911-9945"]},"institutions":[{"id":"https://openalex.org/I2801941315","display_name":"General Electric (Canada)","ror":"https://ror.org/00rey4c89","country_code":"CA","type":"company","lineage":["https://openalex.org/I1332737386","https://openalex.org/I2801941315"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Lubomir Sevov","raw_affiliation_strings":["GE Multilin, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"GE Multilin, Canada","institution_ids":["https://openalex.org/I2801941315"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5028676559","display_name":"Ilia Voloh","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I2801941315","display_name":"General Electric (Canada)","ror":"https://ror.org/00rey4c89","country_code":"CA","type":"company","lineage":["https://openalex.org/I1332737386","https://openalex.org/I2801941315"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Ilia Voloh","raw_affiliation_strings":["GE Multilin, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"GE Multilin, Canada","institution_ids":["https://openalex.org/I2801941315"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I2801941315"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.18624794,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"402","last_page":"416"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12692","display_name":"Magnetic Field Sensors Techniques","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/overcurrent-protection","display_name":"overcurrent protection","score":0.9200000166893005},{"id":"https://openalex.org/keywords/current-transformer-saturation","display_name":"current transformer saturation","score":0.9769999980926514},{"id":"https://openalex.org/keywords/numerical-relays","display_name":"numerical relays","score":0.8169999718666077},{"id":"https://openalex.org/keywords/short-circuit-protection","display_name":"short-circuit protection","score":0.7940000295639038},{"id":"https://openalex.org/keywords/industrial-power-systems","display_name":"industrial power systems","score":0.6489999890327454}],"concepts":[{"id":"https://openalex.org/C47949032","wikidata":"https://www.wikidata.org/wiki/Q663542","display_name":"Overcurrent","level":3,"score":0.9205856323242188},{"id":"https://openalex.org/C9930424","wikidata":"https://www.wikidata.org/wiki/Q7426587","display_name":"Saturation (graph theory)","level":2,"score":0.6284648180007935},{"id":"https://openalex.org/C133770746","wikidata":"https://www.wikidata.org/wiki/Q856535","display_name":"Current transformer","level":4,"score":0.6043724417686462},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.5491870641708374},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5443993210792542},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4672546088695526},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.4313729405403137},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.36020612716674805},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.30139416456222534},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2714841961860657},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.24532172083854675},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.1425989866256714},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.13237285614013672},{"id":"https://openalex.org/C114614502","wikidata":"https://www.wikidata.org/wiki/Q76592","display_name":"Combinatorics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/cpre.2009.4982529","doi":"https://doi.org/10.1109/cpre.2009.4982529","is_oa":false,"landing_page_url":"https://doi.org/10.1109/cpre.2009.4982529","pdf_url":null,"source":{"id":"https://openalex.org/S4306418003","display_name":"Conference for Protective Relay Engineers","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2009 62nd Annual Conference for Protective Relay Engineers","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","score":0.5378999710083008,"display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":3,"referenced_works":["https://openalex.org/W1964100900","https://openalex.org/W2037716403","https://openalex.org/W6641428618"],"related_works":["https://openalex.org/W2037716403","https://openalex.org/W3147459690","https://openalex.org/W6997777295","https://openalex.org/W2358658013","https://openalex.org/W2608669168","https://openalex.org/W2073148173","https://openalex.org/W2033940309","https://openalex.org/W2355039724","https://openalex.org/W2883920184","https://openalex.org/W2141519932"],"abstract_inverted_index":{"The":[0],"computational":[1],"capabilities":[2],"of":[3,9,20,28,38],"numerical":[4],"relays":[5],"allow":[6],"the":[7,33,65],"development":[8],"sophisticated":[10],"overcurrent":[11],"algorithms.":[12],"These":[13],"algorithms":[14],"ensure":[15],"dependable":[16],"and":[17,41],"fast":[18],"operation":[19],"short":[21],"circuit":[22],"protection":[23],"even":[24],"under":[25],"severe":[26],"saturation":[27,56],"current":[29],"transformers.":[30],"This":[31],"eliminates":[32],"need":[34],"for":[35],"impractical":[36],"engineering":[37],"such":[39],"applications,":[40],"increases":[42],"confidence":[43],"levels":[44],"in":[45],"cases":[46],"with":[47],"relatively":[48],"well-rated":[49],"CTs":[50],"that":[51],"do":[52],"not":[53],"experience":[54],"extreme":[55],"but":[57],"are":[58],"exposed":[59],"to":[60],"currents":[61],"much":[62],"higher":[63],"than":[64],"conventional":[66],"20":[67],"times":[68],"rated.":[69]},"counts_by_year":[],"updated_date":"2026-10-05T09:50:58.205359","created_date":"2016-06-24T00:00:00"}
