{"id":"https://openalex.org/W2107448886","doi":"https://doi.org/10.1109/tuffc.2005.1417268","title":"Piezoelectric micromachined ultrasonic transducers: modeling the influence of structural parameters on device performance","display_name":"Piezoelectric micromachined ultrasonic transducers: modeling the influence of structural parameters on device performance","publication_year":2005,"publication_date":"2005-03-01","ids":{"openalex":"https://openalex.org/W2107448886","doi":"https://doi.org/10.1109/tuffc.2005.1417268","mag":"2107448886","pmid":"https://pubmed.ncbi.nlm.nih.gov/15857054"},"language":"en","primary_location":{"id":"doi:10.1109/tuffc.2005.1417268","doi":"https://doi.org/10.1109/tuffc.2005.1417268","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tuffc.2005.1417268","pdf_url":null,"source":{"id":"https://openalex.org/S120877133","display_name":"IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control","issn_l":"0885-3010","issn":["0885-3010","1525-8955","2373-7840"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-a","doyens","jufo-2","ki-jl-1","poland-100","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5112285317","display_name":"Firas Akasheh","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I72951846","display_name":"Washington State University","ror":"https://ror.org/05dk0ce17","country_code":"US","type":"education","lineage":["https://openalex.org/I72951846"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"F. Akasheh","raw_affiliation_strings":["School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99164, USA","Sch. of Mech. & Mater. Eng., Washington State Univ., Pullman, WA, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99164, USA","institution_ids":["https://openalex.org/I72951846"]},{"raw_affiliation_string":"Sch. of Mech. & Mater. Eng., Washington State Univ., Pullman, WA, USA","institution_ids":["https://openalex.org/I72951846"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5023641131","display_name":"John Douglas Fraser","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"J.D. Fraser","raw_affiliation_strings":["Philips Ultrasound, Bothell, WA, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Philips Ultrasound, Bothell, WA, USA","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5025156200","display_name":"Susmita Bose","orcid":"https://orcid.org/0000-0001-8601-016X","observed_orcids":["https://orcid.org/0000-0001-8601-016X"]},"institutions":[{"id":"https://openalex.org/I72951846","display_name":"Washington State University","ror":"https://ror.org/05dk0ce17","country_code":"US","type":"education","lineage":["https://openalex.org/I72951846"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"S. Bose","raw_affiliation_strings":["School of Mechanical and Materials Engineering, Washington State University, Pullman, WA, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Mechanical and Materials Engineering, Washington State University, Pullman, WA, USA","institution_ids":["https://openalex.org/I72951846"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5000075961","display_name":"Amit Kumar Bandyopadhyay","orcid":"https://orcid.org/0000-0003-0992-5387","observed_orcids":["https://orcid.org/0000-0003-0992-5387"]},"institutions":[{"id":"https://openalex.org/I72951846","display_name":"Washington State University","ror":"https://ror.org/05dk0ce17","country_code":"US","type":"education","lineage":["https://openalex.org/I72951846"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"A. Bandyopadhyay","raw_affiliation_strings":["School of Mechanical and Materials Engineering, Washington State University, Pullman, WA, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Mechanical and Materials Engineering, Washington State University, Pullman, WA, USA","institution_ids":["https://openalex.org/I72951846"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":2645,"currency":"USD","value_usd":2645},"apc_paid":null,"fwci":4.1842,"has_fulltext":false,"cited_by_count":71,"citation_normalized_percentile":{"value":0.9380923,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":93,"max":99},"biblio":{"volume":"52","issue":"3","first_page":"455","last_page":"468"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10662","display_name":"Ultrasonics and Acoustic Wave Propagation","score":0.9413999915122986,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10662","display_name":"Ultrasonics and Acoustic Wave Propagation","score":0.9413999915122986,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10107","display_name":"Ferroelectric and Piezoelectric Materials","score":0.01979999989271164,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11525","display_name":"Piezoelectric Actuators and Control","score":0.010599999688565731,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/piezoelectric-micromachined-ultrasonic-transducers","display_name":"piezoelectric micromachined ultrasonic transducers","score":0.996999979019165},{"id":"https://openalex.org/keywords/lead-zirconate-titanate","display_name":"lead zirconate titanate","score":0.9779999852180481},{"id":"https://openalex.org/keywords/coupling-coefficient","display_name":"coupling coefficient","score":0.9120000004768372},{"id":"https://openalex.org/keywords/acoustic-impedance","display_name":"acoustic impedance","score":0.9229999780654907},{"id":"https://openalex.org/keywords/finite-element-analysis","display_name":"finite element analysis","score":0.6880000233650208},{"id":"https://openalex.org/keywords/bandwidth","display_name":"bandwidth","score":0.8019999861717224},{"id":"https://openalex.org/keywords/resonant-frequency","display_name":"resonant frequency","score":0.6470000147819519}],"concepts":[{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.7812420129776001},{"id":"https://openalex.org/C86194701","wikidata":"https://www.wikidata.org/wiki/Q2981748","display_name":"Electromechanical coupling coefficient","level":3,"score":0.754857063293457},{"id":"https://openalex.org/C58772458","wikidata":"https://www.wikidata.org/wiki/Q5034480","display_name":"Capacitive micromachined ultrasonic transducers","level":3,"score":0.7327057719230652},{"id":"https://openalex.org/C81288441","wikidata":"https://www.wikidata.org/wiki/Q20736125","display_name":"Ultrasonic sensor","level":2,"score":0.7217161655426025},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.6756335496902466},{"id":"https://openalex.org/C100082104","wikidata":"https://www.wikidata.org/wiki/Q183759","display_name":"Piezoelectricity","level":2,"score":0.6615791320800781},{"id":"https://openalex.org/C2781128178","wikidata":"https://www.wikidata.org/wiki/Q883484","display_name":"Lead zirconate titanate","level":4,"score":0.6160555481910706},{"id":"https://openalex.org/C57693265","wikidata":"https://www.wikidata.org/wiki/Q17105295","display_name":"PMUT","level":3,"score":0.6105888485908508},{"id":"https://openalex.org/C56318395","wikidata":"https://www.wikidata.org/wiki/Q215928","display_name":"Transducer","level":2,"score":0.5975677371025085},{"id":"https://openalex.org/C91397564","wikidata":"https://www.wikidata.org/wiki/Q15059729","display_name":"Coupling coefficient of resonators","level":3,"score":0.551559329032898},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.5176166296005249},{"id":"https://openalex.org/C2776257435","wikidata":"https://www.wikidata.org/wiki/Q1576430","display_name":"Bandwidth (computing)","level":2,"score":0.4570912718772888},{"id":"https://openalex.org/C98937189","wikidata":"https://www.wikidata.org/wiki/Q975684","display_name":"Acoustic impedance","level":3,"score":0.4265555441379547},{"id":"https://openalex.org/C612350","wikidata":"https://www.wikidata.org/wiki/Q1761108","display_name":"Impedance matching","level":3,"score":0.41638708114624023},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3428076505661011},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.2637732923030853},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.14992499351501465},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.12471359968185425},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.12218761444091797},{"id":"https://openalex.org/C133386390","wikidata":"https://www.wikidata.org/wiki/Q184996","display_name":"Dielectric","level":2,"score":0.10666435956954956},{"id":"https://openalex.org/C79090758","wikidata":"https://www.wikidata.org/wiki/Q1045739","display_name":"Ferroelectricity","level":3,"score":0.07414689660072327},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.0},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.0},{"id":"https://openalex.org/C97126364","wikidata":"https://www.wikidata.org/wiki/Q349669","display_name":"Resonator","level":2,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/tuffc.2005.1417268","doi":"https://doi.org/10.1109/tuffc.2005.1417268","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tuffc.2005.1417268","pdf_url":null,"source":{"id":"https://openalex.org/S120877133","display_name":"IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control","issn_l":"0885-3010","issn":["0885-3010","1525-8955","2373-7840"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-a","doyens","jufo-2","ki-jl-1","poland-100","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control","raw_type":"journal-article"},{"id":"pmid:15857054","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/15857054","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on ultrasonics, ferroelectrics, and frequency control","raw_type":"Journal Article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":43,"referenced_works":["https://openalex.org/W11882822","https://openalex.org/W160503773","https://openalex.org/W1546545591","https://openalex.org/W1750564206","https://openalex.org/W1974445719","https://openalex.org/W1984028354","https://openalex.org/W1990544299","https://openalex.org/W1993029601","https://openalex.org/W1998717539","https://openalex.org/W2015621384","https://openalex.org/W2023325937","https://openalex.org/W2029383242","https://openalex.org/W2050866592","https://openalex.org/W2051847435","https://openalex.org/W2060035389","https://openalex.org/W2070244938","https://openalex.org/W2072840621","https://openalex.org/W2092557702","https://openalex.org/W2102196727","https://openalex.org/W2106099469","https://openalex.org/W2110074934","https://openalex.org/W2117433871","https://openalex.org/W2118220612","https://openalex.org/W2120101310","https://openalex.org/W2122905951","https://openalex.org/W2124204395","https://openalex.org/W2137562317","https://openalex.org/W2144682883","https://openalex.org/W2148822556","https://openalex.org/W2150790052","https://openalex.org/W2151044682","https://openalex.org/W2154468315","https://openalex.org/W2159442239","https://openalex.org/W2162551539","https://openalex.org/W2163011994","https://openalex.org/W2163338574","https://openalex.org/W2170181806","https://openalex.org/W2223526798","https://openalex.org/W2313016525","https://openalex.org/W2504380268","https://openalex.org/W2517582135","https://openalex.org/W4285719527","https://openalex.org/W6726456723"],"related_works":["https://openalex.org/W2023325937","https://openalex.org/W2124726994","https://openalex.org/W2552096480","https://openalex.org/W2389505578","https://openalex.org/W2116241686","https://openalex.org/W1964964564","https://openalex.org/W3026484128","https://openalex.org/W2076566337","https://openalex.org/W7149570766","https://openalex.org/W4393042001"],"abstract_inverted_index":{"Piezoelectric":[0],"micromachined":[1],"ultrasonic":[2,13],"transducers":[3],"(pMUTs),":[4],"a":[5,19,45,57,97,156],"potential":[6],"alternative":[7],"for":[8,32,40,54],"conventional":[9,173],"one-dimensional":[10],"phased":[11],"array":[12],"transducers,":[14,174],"were":[15],"investigated.":[16],"We":[17],"used":[18],"modeling":[20],"approach":[21],"to":[22,65,167,170],"study":[23],"the":[24,33,55,69,74,77,82,86,95,108,118,135,146,151,161],"performance":[25],"of":[26,36,47,160,172],"lead":[27],"zirconate":[28],"titanate":[29],"(PZT)-driven":[30],"pMUTs":[31],"frequency":[34,90],"range":[35],"2-10":[37],"MHz,":[38],"optimized":[39],"maximum":[41],"coupling":[42,79,119,147],"coefficient,":[43],"as":[44,132,134],"function":[46],"device":[48,70,78,99,152],"design.":[49,138],"Using":[50],"original":[51],"tools":[52],"designed":[53],"purpose,":[56],"comprehensive":[58],"build-test":[59],"finite":[60],"element":[61],"model":[62,75,109],"was":[63,100],"developed":[64],"predict":[66],"and":[67,81,91,102,111,128],"measure":[68],"performance.":[71],"In":[72],"particular,":[73],"estimates":[76],"coefficient":[80,120,148],"acoustic":[83,153],"impedance,":[84],"besides":[85],"readily":[87],"extractable":[88],"resonance":[89],"bandwidth.":[92],"To":[93],"validate":[94],"model,":[96],"prototype":[98],"built":[101],"tested,":[103],"showing":[104],"good":[105],"agreement":[106],"between":[107],"predictions":[110],"experimental":[112],"results.":[113],"Modeling":[114],"results":[115],"indicate":[116,141],"that":[117,159,171],"is":[121],"significantly":[122],"affected":[123],"by":[124],"silicon":[125],"membrane,":[126],"PZT,":[127],"top":[129,136],"electrode":[130,137],"thickness":[131],"well":[133],"Results":[139],"also":[140],"considerable":[142],"flexibility":[143],"in":[144,177],"maximizing":[145],"while":[149],"maintaining":[150],"impedance":[154],"at":[155],"level":[157],"matching":[158],"human":[162],"body.":[163],"The":[164],"bandwidth":[165],"proved":[166],"be":[168],"superior":[169],"reaching":[175],"102%":[176],"some":[178],"cases.":[179]},"counts_by_year":[{"year":2026,"cited_by_count":3},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":4},{"year":2022,"cited_by_count":5},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":6},{"year":2019,"cited_by_count":5},{"year":2018,"cited_by_count":7},{"year":2017,"cited_by_count":5},{"year":2016,"cited_by_count":5},{"year":2015,"cited_by_count":6},{"year":2014,"cited_by_count":4},{"year":2012,"cited_by_count":2}],"updated_date":"2026-10-30T12:39:25.321706","created_date":"2016-06-24T00:00:00"}
