{"id":"https://openalex.org/W2104808697","doi":"https://doi.org/10.1109/ptc.2005.4524646","title":"Protection of MV covered conductor lines against overvoltages and fault arcs","display_name":"Protection of MV covered conductor lines against overvoltages and fault arcs","alternate_titles":[],"publication_year":2005,"publication_date":"2005-06-01","ids":{"openalex":"https://openalex.org/W2104808697","doi":"https://doi.org/10.1109/ptc.2005.4524646","mag":"2104808697"},"language":"en","primary_location":{"id":"doi:10.1109/ptc.2005.4524646","doi":"https://doi.org/10.1109/ptc.2005.4524646","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ptc.2005.4524646","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2005 IEEE Russia Power Tech","raw_type":"proceedings-article"},"parent_works":[],"lineage":["https://openalex.org/W2104808697"],"child_works_count":0,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"G. Ban","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I29770179","display_name":"Budapest University of Technology and Economics","ror":"https://ror.org/02w42ss30","country_code":"HU","type":"education","lineage":["https://openalex.org/I29770179"]}],"countries":["HU"],"is_corresponding":false,"raw_author_name":"G. Ban","raw_affiliation_strings":["Budapest University\uc2a0of\uc2a0Technology\uc2a0and\uc2a0Economics, Budapest, Hungary","Budapest University of Technology and Economics, Budapest,"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Budapest University\uc2a0of\uc2a0Technology\uc2a0and\uc2a0Economics, Budapest, Hungary","institution_ids":["https://openalex.org/I29770179"]},{"raw_affiliation_string":"Budapest University of Technology and Economics, Budapest,","institution_ids":["https://openalex.org/I29770179"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5053941596","display_name":"L. Prikler","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I29770179","display_name":"Budapest University of Technology and Economics","ror":"https://ror.org/02w42ss30","country_code":"HU","type":"education","lineage":["https://openalex.org/I29770179"]}],"countries":["HU"],"is_corresponding":false,"raw_author_name":"L. Prikler","raw_affiliation_strings":["Budapest University\uc2a0of\uc2a0Technology\uc2a0and\uc2a0Economics, Budapest, Hungary","Budapest University of Technology and Economics, Budapest,"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Budapest University\uc2a0of\uc2a0Technology\uc2a0and\uc2a0Economics, Budapest, Hungary","institution_ids":["https://openalex.org/I29770179"]},{"raw_affiliation_string":"Budapest University of Technology and Economics, Budapest,","institution_ids":["https://openalex.org/I29770179"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5086493872","display_name":"I. Fogarasi","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210114343","display_name":"Veiki-VNL (Hungary)","ror":"https://ror.org/02hgg3s41","country_code":"HU","type":"company","lineage":["https://openalex.org/I4210114343"]}],"countries":["HU"],"is_corresponding":false,"raw_author_name":"I. Fogarasi","raw_affiliation_strings":["VEIKI-VNL Electric Large Laboratories Limited, Budapest, Hungary","VEIKI-VNL Electric Large Laboratories Ltd., Budapest, Hungary"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"VEIKI-VNL Electric Large Laboratories Limited, Budapest, Hungary","institution_ids":["https://openalex.org/I4210114343"]},{"raw_affiliation_string":"VEIKI-VNL Electric Large Laboratories Ltd., Budapest, Hungary","institution_ids":["https://openalex.org/I4210114343"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5021100381","display_name":"I. Hajos","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I7597260","display_name":"Hungarian Academy of Sciences","ror":"https://ror.org/02ks8qq67","country_code":"HU","type":"government","lineage":["https://openalex.org/I7597260"]}],"countries":["HU"],"is_corresponding":false,"raw_author_name":"I. Hajos","raw_affiliation_strings":["E. ON-DEDASZ Limited, Pecs, Hungary","E.ON - DEDASZ Ltd. Pecs, Hungary"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"E. ON-DEDASZ Limited, Pecs, Hungary","institution_ids":["https://openalex.org/I7597260"]},{"raw_affiliation_string":"E.ON - DEDASZ Ltd. Pecs, Hungary","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"7"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.19419999420642853,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.19419999420642853,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10787","display_name":"Lightning and Electromagnetic Phenomena","score":0.18639999628067017,"subfield":{"id":"https://openalex.org/subfields/1902","display_name":"Atmospheric Science"},"field":{"id":"https://openalex.org/fields/19","display_name":"Earth and Planetary Sciences"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.14820000529289246,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/covered-conductors","display_name":"covered conductors","score":0.6909999847412109},{"id":"https://openalex.org/keywords/medium-voltage-overhead-lines","display_name":"medium voltage overhead lines","score":0.8199999928474426},{"id":"https://openalex.org/keywords/overvoltage-protection","display_name":"overvoltage protection","score":0.7739999890327454},{"id":"https://openalex.org/keywords/arc-faults","display_name":"arc faults","score":0.8040000200271606},{"id":"https://openalex.org/keywords/flashover-mechanism","display_name":"flashover mechanism","score":0.7699999809265137},{"id":"https://openalex.org/keywords/arc-initiation","display_name":"arc initiation","score":0.6240000128746033},{"id":"https://openalex.org/keywords/conductor-damage","display_name":"conductor damage","score":0.49900001287460327},{"id":"https://openalex.org/keywords/forest-corridors","display_name":"forest corridors","score":0.4050000011920929},{"id":"https://openalex.org/keywords/line-crossing","display_name":"line crossing","score":0.3009999990463257}],"concepts":[{"id":"https://openalex.org/C34800285","wikidata":"https://www.wikidata.org/wiki/Q5159395","display_name":"Conductor","level":2,"score":0.8421022891998291},{"id":"https://openalex.org/C202374169","wikidata":"https://www.wikidata.org/wiki/Q124291","display_name":"Electrical conductor","level":2,"score":0.7955704927444458},{"id":"https://openalex.org/C200769187","wikidata":"https://www.wikidata.org/wiki/Q2360656","display_name":"Arc flash","level":3,"score":0.7757904529571533},{"id":"https://openalex.org/C2775861652","wikidata":"https://www.wikidata.org/wiki/Q110701","display_name":"Overhead line","level":2,"score":0.6601779460906982},{"id":"https://openalex.org/C212702","wikidata":"https://www.wikidata.org/wiki/Q178150","display_name":"Insulator (electricity)","level":2,"score":0.5967877507209778},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5861691832542419},{"id":"https://openalex.org/C2777831296","wikidata":"https://www.wikidata.org/wiki/Q12518","display_name":"Tower","level":2,"score":0.5341761112213135},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.5076650381088257},{"id":"https://openalex.org/C2779960059","wikidata":"https://www.wikidata.org/wiki/Q7113681","display_name":"Overhead (engineering)","level":2,"score":0.45325711369514465},{"id":"https://openalex.org/C198352243","wikidata":"https://www.wikidata.org/wiki/Q37105","display_name":"Line (geometry)","level":2,"score":0.4292777180671692},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3729723393917084},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.3642323613166809},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.12451261281967163},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ptc.2005.4524646","doi":"https://doi.org/10.1109/ptc.2005.4524646","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ptc.2005.4524646","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2005 IEEE Russia Power Tech","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.7207000255584717}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W1957664741","https://openalex.org/W1972836439","https://openalex.org/W1974742193","https://openalex.org/W2116490178","https://openalex.org/W2135628559","https://openalex.org/W2139289487","https://openalex.org/W2141187712","https://openalex.org/W2165799524","https://openalex.org/W3146073127","https://openalex.org/W4249710311"],"related_works":["https://openalex.org/W2774054999","https://openalex.org/W2352991712","https://openalex.org/W2018480464","https://openalex.org/W2890046661","https://openalex.org/W2160076263","https://openalex.org/W1998904824","https://openalex.org/W2187829296","https://openalex.org/W3117986542","https://openalex.org/W2050375274","https://openalex.org/W2129952059"],"abstract_inverted_index":{"Reduction":[0],"of":[1,25,47,107],"the":[2,16,23,52,68,73,79,85,98,103,108],"line":[3,63],"and":[4,75,93,123],"tower":[5],"dimensions":[6],"is":[7],"a":[8,125],"common":[9],"tool":[10],"to":[11],"insert":[12],"overhead":[13],"lines":[14,53],"into":[15],"environment.":[17],"Recently":[18],"such":[19],"trends":[20],"occurred":[21],"in":[22,71,124],"field":[24],"MV":[26],"networks,":[27],"as":[28],"well.":[29],"When":[30],"applying":[31],"covered":[32,48],"conductors":[33],"shorter":[34],"phase-to-phase":[35],"distances":[36],"can":[37],"be":[38],"allowed":[39],"than":[40],"with":[41],"bare":[42],"conductors.":[43],"Important":[44],"application":[45],"areas":[46,61],"conductor":[49,110],"system":[50],"are":[51],"passing":[54],"through":[55],"forests":[56],"(allowing":[57],"narrow":[58],"corridor),":[59],"inhabited":[60],"or":[62],"crossing.":[64],"This":[65],"paper":[66],"analyses":[67],"processes":[69],"resulting":[70],"damaging":[72],"cover":[74],"conductor,":[76],"reports":[77],"on":[78,97,117],"laboratory":[80,99],"studies":[81],"aiming":[82],"at":[83],"selecting":[84],"suitable":[86],"arc":[87,121],"protecting":[88],"devices,":[89],"establishing":[90],"their":[91],"pros":[92],"cons.":[94],"Authors":[95],"report":[96],"tests":[100,114],"for":[101],"understanding":[102],"complex":[104],"flashover":[105],"mechanism":[106],"insulator-covered":[109],"arrangement.":[111],"Follow":[112],"current":[113],"were":[115],"carried":[116],"by":[118],"thin":[119],"wire":[120],"initiation":[122],"synthetic":[126],"circuit.":[127]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2104808697","counts_by_year":[{"year":2021,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2012,"cited_by_count":2}],"updated_date":"2026-09-29T14:09:16.559479","created_date":"2016-06-24T00:00:00"}
