{"id":"https://openalex.org/W2100463586","doi":"https://doi.org/10.1109/demped.2003.1234564","title":"Artificial neural network based fault identification of HVDC converter","display_name":"Artificial neural network based fault identification of HVDC converter","publication_year":2003,"publication_date":"2003-11-21","ids":{"openalex":"https://openalex.org/W2100463586","doi":"https://doi.org/10.1109/demped.2003.1234564","mag":"2100463586"},"language":"en","primary_location":{"id":"doi:10.1109/demped.2003.1234564","doi":"https://doi.org/10.1109/demped.2003.1234564","is_oa":false,"landing_page_url":"https://doi.org/10.1109/demped.2003.1234564","pdf_url":null,"source":{"id":"https://openalex.org/S7407088471","display_name":"IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"4th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives, 2003. SDEMPED 2003.","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5110193172","display_name":"N. G. Bawane","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"N. Bawane","raw_affiliation_strings":["Government Polytechnic Institute, Nagpur, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Government Polytechnic Institute, Nagpur, India","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5075922092","display_name":"Ashwin Kothari","orcid":"https://orcid.org/0000-0001-6149-5607","observed_orcids":["https://orcid.org/0000-0001-6149-5607"]},"institutions":[{"id":"https://openalex.org/I167153416","display_name":"Visvesvaraya National Institute of Technology","ror":"https://ror.org/02zrtpp84","country_code":"IN","type":"education","lineage":["https://openalex.org/I167153416"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"A.G. Kothari","raw_affiliation_strings":["Visvesvaraya National Institute of Technology, Nagpur, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Visvesvaraya National Institute of Technology, Nagpur, India","institution_ids":["https://openalex.org/I167153416"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.899,"has_fulltext":false,"cited_by_count":22,"citation_normalized_percentile":{"value":0.67487812,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"152","last_page":"157"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9258000254631042,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9258000254631042,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.07029999792575836,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.0010999999940395355,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hvdc-converters","display_name":"HVDC converters","score":0.8510000109672546},{"id":"https://openalex.org/keywords/fault-identification","display_name":"fault identification","score":0.9929999709129333},{"id":"https://openalex.org/keywords/neural-network","display_name":"artificial neural networks","score":0.7710000276565552},{"id":"https://openalex.org/keywords/hvdc-protection","display_name":"HVDC protection","score":0.7739999890327454},{"id":"https://openalex.org/keywords/fault-classification","display_name":"fault classification","score":0.5600000023841858},{"id":"https://openalex.org/keywords/ac-dc-power-systems","display_name":"AC/DC power systems","score":0.7609999775886536},{"id":"https://openalex.org/keywords/power-converter-control","display_name":"converter control","score":0.5210000276565552},{"id":"https://openalex.org/keywords/dynamic-response","display_name":"dynamic response","score":0.6380000114440918}],"concepts":[{"id":"https://openalex.org/C154504017","wikidata":"https://www.wikidata.org/wiki/Q853614","display_name":"Identifier","level":2,"score":0.8300794363021851},{"id":"https://openalex.org/C2780705257","wikidata":"https://www.wikidata.org/wiki/Q5636221","display_name":"HVDC converter","level":4,"score":0.7249313592910767},{"id":"https://openalex.org/C50644808","wikidata":"https://www.wikidata.org/wiki/Q192776","display_name":"Artificial neural network","level":2,"score":0.6975163221359253},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6596957445144653},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6002670526504517},{"id":"https://openalex.org/C7904685","wikidata":"https://www.wikidata.org/wiki/Q2356943","display_name":"HVDC converter station","level":3,"score":0.5528556108474731},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.5488775372505188},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5298488140106201},{"id":"https://openalex.org/C116834253","wikidata":"https://www.wikidata.org/wiki/Q2039217","display_name":"Identification (biology)","level":2,"score":0.4848650395870209},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.42414340376853943},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.40451478958129883},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3526819348335266},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3367130756378174},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3327513337135315},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.22548836469650269},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.19020745158195496},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.18120363354682922},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.12021803855895996},{"id":"https://openalex.org/C59822182","wikidata":"https://www.wikidata.org/wiki/Q441","display_name":"Botany","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/demped.2003.1234564","doi":"https://doi.org/10.1109/demped.2003.1234564","is_oa":false,"landing_page_url":"https://doi.org/10.1109/demped.2003.1234564","pdf_url":null,"source":{"id":"https://openalex.org/S7407088471","display_name":"IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"4th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives, 2003. SDEMPED 2003.","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.75,"display_name":"Affordable and clean energy"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":7,"referenced_works":["https://openalex.org/W1942672250","https://openalex.org/W2067699254","https://openalex.org/W2088443926","https://openalex.org/W2112527463","https://openalex.org/W2142899655","https://openalex.org/W6640611944","https://openalex.org/W6986486396"],"related_works":["https://openalex.org/W1972824284","https://openalex.org/W7096977945","https://openalex.org/W2278798007","https://openalex.org/W2736731288","https://openalex.org/W1602000848","https://openalex.org/W2886288264","https://openalex.org/W2087512061","https://openalex.org/W2674279869","https://openalex.org/W7100235693","https://openalex.org/W2563738539"],"abstract_inverted_index":{"This":[0],"paper":[1],"investigates":[2],"the":[3,16,35,48,105,109,129],"possibility":[4],"of":[5,18,27,51,104,108],"using":[6],"a":[7,33,94],"neural":[8,61],"network":[9,20,62],"for":[10,91,128],"HVDC":[11,71,92,130],"converter":[12,72],"protection.":[13],"Based":[14],"on":[15],"ability":[17],"this":[19,57],"to":[21,46,65,118],"distinguish":[22,66],"reliably":[23],"between":[24,77],"different":[25,67,82],"types":[26],"faults":[28,68],"that":[29],"may":[30],"occur":[31],"in":[32,69],"converter,":[34],"feature":[36],"can":[37,115],"be":[38,116],"suitably":[39],"integrated":[40,121],"with":[41,93,125],"an":[42,52,70,120],"ANN":[43,122],"based":[44,63,123],"controller":[45,124],"improve":[47],"dynamic":[49],"response":[50],"AC-DC":[53],"power":[54],"system.":[55,131],"In":[56],"paper,":[58],"three":[59],"new":[60],"methods":[64],"are":[73],"proposed":[74,112],"and":[75,85,96],"comparison":[76],"them":[78],"is":[79,89,102],"made":[80],"under":[81],"system":[83],"perturbations":[84],"faults.":[86],"The":[87,100,111],"identifier":[88,114,127],"tested":[90],"strong":[95],"weak":[97],"AC":[98],"side.":[99],"method":[101],"independent":[103],"operating":[106],"mode":[107],"converter.":[110],"fault":[113,126],"used":[117],"design":[119]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":2},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":1},{"year":2012,"cited_by_count":1}],"updated_date":"2026-10-27T15:51:10.671819","created_date":"2016-06-24T00:00:00"}