{"id":"https://openalex.org/W2099120237","doi":"https://doi.org/10.1109/papcon.2010.5556501","title":"Transformer failure due to circuit breaker induced switching transients","display_name":"Transformer failure due to circuit breaker induced switching transients","alternate_titles":[],"publication_year":2010,"publication_date":"2010-06-01","ids":{"openalex":"https://openalex.org/W2099120237","doi":"https://doi.org/10.1109/papcon.2010.5556501","mag":"2099120237"},"language":"en","primary_location":{"id":"doi:10.1109/papcon.2010.5556501","doi":"https://doi.org/10.1109/papcon.2010.5556501","is_oa":false,"landing_page_url":"https://doi.org/10.1109/papcon.2010.5556501","pdf_url":null,"source":{"id":"https://openalex.org/S4210177915","display_name":"IEEE Conference record of annual Pulp and Paper Industry Technical Conference","issn_l":"0190-2172","issn":["0190-2172"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Conference Record of 2010 Annual Pulp &amp; Paper Industry Technical Conference","raw_type":"proceedings-article"},"parent_works":[{"id":"https://openalex.org/W4254194918","display_name":"Conference Record of 2010 Annual Pulp & Paper Industry Technical Conference","relationship":"volume","link_type":"volume"}],"lineage":["https://openalex.org/W2099120237","https://openalex.org/W4254194918"],"child_works_count":0,"pull_notice_works":[],"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5067399771","display_name":"David D. Shipp","type":null,"orcid":"https://orcid.org/0000-0001-9610-8814","observed_orcids":["https://orcid.org/0000-0001-9610-8814","https://orcid.org/0000-0003-3055-0284"]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I4210091818","display_name":"Eaton (United States)","ror":"https://ror.org/00czndn44","country_code":"US","type":"company","lineage":["https://openalex.org/I4210091818","https://openalex.org/I4210139942"]}],"countries":["US"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"David D. Shipp","raw_affiliation_strings":["Eaton Electrical, Inc., Warrendale, PA, USA","[Eaton Electrical Group, 130 Commonwealth Dr., Warrendale, PA 15086, USA]"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Eaton Electrical, Inc., Warrendale, PA, USA","institution_ids":["https://openalex.org/I4210091818"]},{"raw_affiliation_string":"[Eaton Electrical Group, 130 Commonwealth Dr., Warrendale, PA 15086, USA]","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5083309044","display_name":"Thomas J. Dionise","type":null,"orcid":"https://orcid.org/0000-0001-5786-8431","observed_orcids":["https://orcid.org/0000-0001-5786-8431"]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I4210091818","display_name":"Eaton (United States)","ror":"https://ror.org/00czndn44","country_code":"US","type":"company","lineage":["https://openalex.org/I4210091818","https://openalex.org/I4210139942"]}],"countries":["US"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Thomas J. Dionise","raw_affiliation_strings":["Eaton Electrical, Inc., Warrendale, PA, USA","[Eaton Electrical Group, 130 Commonwealth Dr., Warrendale, PA 15086, USA]"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Eaton Electrical, Inc., Warrendale, PA, USA","institution_ids":["https://openalex.org/I4210091818"]},{"raw_affiliation_string":"[Eaton Electrical Group, 130 Commonwealth Dr., Warrendale, PA 15086, USA]","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5042257401","display_name":"Visuth Lorch","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I4210091818","display_name":"Eaton (United States)","ror":"https://ror.org/00czndn44","country_code":"US","type":"company","lineage":["https://openalex.org/I4210091818","https://openalex.org/I4210139942"]}],"countries":["US"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Visuth Lorch","raw_affiliation_strings":["Eaton Electrical, Inc., Warrendale, PA, USA","[Eaton Electrical Group, 130 Commonwealth Dr., Warrendale, PA 15086, USA]"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Eaton Electrical, Inc., Warrendale, PA, USA","institution_ids":["https://openalex.org/I4210091818"]},{"raw_affiliation_string":"[Eaton Electrical Group, 130 Commonwealth Dr., Warrendale, PA 15086, USA]","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5056008084","display_name":"Bill G MacFarlane","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[{"id":"https://openalex.org/I4210091818","display_name":"Eaton (United States)","ror":"https://ror.org/00czndn44","country_code":"US","type":"company","lineage":["https://openalex.org/I4210091818","https://openalex.org/I4210139942"]}],"countries":["US"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Bill G MacFarlane","raw_affiliation_strings":["Eaton Electrical, Inc., Warrendale, PA, USA","[Eaton Electrical Group, 130 Commonwealth Dr., Warrendale, PA 15086, USA]"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Eaton Electrical, Inc., Warrendale, PA, USA","institution_ids":["https://openalex.org/I4210091818"]},{"raw_affiliation_string":"[Eaton Electrical Group, 130 Commonwealth Dr., Warrendale, PA 15086, USA]","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I4210091818"],"apc_list":null,"apc_paid":null,"fwci":1.6637,"has_fulltext":false,"cited_by_count":11,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.80605149,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"10"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.4207000136375427,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.4207000136375427,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11444","display_name":"Electromagnetic Compatibility and Noise Suppression","score":0.30489999055862427,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.12680000066757202,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/transformer-failure","display_name":"transformer failure","score":0.8970000147819519},{"id":"https://openalex.org/keywords/vacuum-circuit-breakers","display_name":"vacuum circuit breakers","score":0.7889999747276306},{"id":"https://openalex.org/keywords/sf6-circuit-breakers","display_name":"SF6 circuit breakers","score":0.9539999961853027},{"id":"https://openalex.org/keywords/current-chopping","display_name":"current chopping","score":0.8209999799728394},{"id":"https://openalex.org/keywords/voltage-surges","display_name":"surge voltage","score":0.6669999957084656},{"id":"https://openalex.org/keywords/dry-type-transformers","display_name":"dry-type transformers","score":0.8799999952316284},{"id":"https://openalex.org/keywords/liquid-filled-transformers","display_name":"liquid-filled transformers","score":0.7170000076293945},{"id":"https://openalex.org/keywords/snubbers","display_name":"snubbers","score":0.718999981880188},{"id":"https://openalex.org/keywords/surge-arresters","display_name":"surge arresters","score":0.9490000009536743},{"id":"https://openalex.org/keywords/transient-simulation","display_name":"transient simulation","score":0.574999988079071},{"id":"https://openalex.org/keywords/emtp","display_name":"EMTP","score":0.7289999723434448}],"concepts":[{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.8575267791748047},{"id":"https://openalex.org/C58018660","wikidata":"https://www.wikidata.org/wiki/Q1975192","display_name":"Snubber","level":4,"score":0.7977113723754883},{"id":"https://openalex.org/C179087008","wikidata":"https://www.wikidata.org/wiki/Q14190856","display_name":"Surge arrester","level":3,"score":0.7357962727546692},{"id":"https://openalex.org/C2778363592","wikidata":"https://www.wikidata.org/wiki/Q5374837","display_name":"Emtp","level":4,"score":0.6855708956718445},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.6431658267974854},{"id":"https://openalex.org/C30403606","wikidata":"https://www.wikidata.org/wiki/Q2981904","display_name":"Electromagnetic coil","level":2,"score":0.5662282109260559},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5332393646240234},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5180745124816895},{"id":"https://openalex.org/C15116251","wikidata":"https://www.wikidata.org/wiki/Q337716","display_name":"Residual-current device","level":3,"score":0.46481001377105713},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.4523329734802246},{"id":"https://openalex.org/C154108245","wikidata":"https://www.wikidata.org/wiki/Q287381","display_name":"Surge","level":2,"score":0.45133668184280396},{"id":"https://openalex.org/C138838965","wikidata":"https://www.wikidata.org/wiki/Q1258026","display_name":"Delta-wye transformer","level":5,"score":0.42756593227386475},{"id":"https://openalex.org/C15703209","wikidata":"https://www.wikidata.org/wiki/Q333883","display_name":"Overvoltage","level":3,"score":0.4228960871696472},{"id":"https://openalex.org/C117323899","wikidata":"https://www.wikidata.org/wiki/Q1907989","display_name":"Distribution transformer","level":4,"score":0.42105355858802795},{"id":"https://openalex.org/C72047438","wikidata":"https://www.wikidata.org/wiki/Q779785","display_name":"Transient recovery voltage","level":5,"score":0.41211652755737305},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.28586697578430176},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.16056403517723083},{"id":"https://openalex.org/C64424096","wikidata":"https://www.wikidata.org/wiki/Q750454","display_name":"Power factor","level":3,"score":0.09520033001899719},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.07165476679801941},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C29586797","wikidata":"https://www.wikidata.org/wiki/Q5163663","display_name":"Constant power circuit","level":4,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/papcon.2010.5556501","doi":"https://doi.org/10.1109/papcon.2010.5556501","is_oa":false,"landing_page_url":"https://doi.org/10.1109/papcon.2010.5556501","pdf_url":null,"source":{"id":"https://openalex.org/S4210177915","display_name":"IEEE Conference record of annual Pulp and Paper Industry Technical Conference","issn_l":"0190-2172","issn":["0190-2172"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Conference Record of 2010 Annual Pulp &amp; Paper Industry Technical Conference","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.7207000255584717}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W2099347426","https://openalex.org/W2146647728","https://openalex.org/W2158933536","https://openalex.org/W2486627628","https://openalex.org/W4235470359"],"related_works":["https://openalex.org/W2022484627","https://openalex.org/W1981135332","https://openalex.org/W7099957443","https://openalex.org/W2180636193","https://openalex.org/W2156114781","https://openalex.org/W4414825615","https://openalex.org/W4251648412","https://openalex.org/W1671765192","https://openalex.org/W2149010174","https://openalex.org/W2918824424"],"abstract_inverted_index":{"Switching":[0],"transients":[1,80,105,166],"associated":[2],"with":[3,123,149],"circuit":[4,27,77,125],"breakers":[5],"have":[6,158],"been":[7,16],"observed":[8],"for":[9],"many":[10],"years.":[11],"Recently":[12],"this":[13],"phenomenon":[14],"has":[15],"attributed":[17],"to":[18,51,75,81,127,145,160],"a":[19,143],"significant":[20],"number":[21],"of":[22,85,117,141],"transformer":[23,31,72,129],"failures":[24,32,73],"involving":[25,56],"primary":[26,40,76],"breaker":[28,78,115,164],"switching.":[29],"These":[30],"had":[33],"common":[34,95],"contributing":[35,96],"factors":[36],"such":[37],"as":[38],"1)":[39],"vacuum":[41],"or":[42,48,58],"SF-6":[43],"breaker,":[44],"2)":[45],"short":[46],"cable":[47],"bus":[49],"connection":[50],"transformer,":[52],"and":[53,62,92,120,132,155,176],"3)":[54],"application":[55],"dry-type":[57],"cast":[59],"coil":[60],"transformers":[61],"some":[63],"liquid":[64],"filled.":[65],"This":[66],"paper":[67],"will":[68,108,135,167],"review":[69],"these":[70,177],"recent":[71],"due":[74],"switching":[79,99,165],"show":[82],"the":[83,89,94,103,139,163],"severity":[84],"damage":[86],"caused":[87],"by":[88],"voltage":[90],"surge":[91,171,173],"discuss":[93],"factors.":[97],"Next,":[98],"transient":[100],"simulations":[101],"in":[102,178],"electromagnetic":[104],"program":[106],"(EMTP)":[107],"give":[109],"case":[110],"studies":[111],"which":[112],"illustrate":[113],"how":[114],"characteristics":[116,126],"current":[118],"chopping":[119],"re-strike":[121],"combine":[122],"critical":[124],"cause":[128],"failure.":[130],"Design":[131],"installation":[133],"considerations":[134],"be":[136,168],"addressed,":[137],"especially":[138],"challenges":[140],"retrofitting":[142],"snubber":[144],"an":[146],"existing":[147],"facility":[148],"limited":[150],"space.":[151],"Finally,":[152],"several":[153],"techniques":[154],"equipment":[156],"that":[157],"proven":[159],"successfully":[161],"mitigate":[162],"presented":[169],"including":[170],"arresters,":[172],"capacitors,":[174],"snubbers":[175],"combination.":[179]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2099120237","counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2015,"cited_by_count":1},{"year":2012,"cited_by_count":2}],"updated_date":"2026-11-22T12:46:00.618207","created_date":"2016-06-24T00:00:00"}