{"id":"https://openalex.org/W2094976745","doi":"https://doi.org/10.1117/1.3037341","title":"Polarization effect on the depth resolution of optical coherence tomography","display_name":"Polarization effect on the depth resolution of optical coherence tomography","publication_year":2008,"publication_date":"2008-11-01","ids":{"openalex":"https://openalex.org/W2094976745","doi":"https://doi.org/10.1117/1.3037341","mag":"2094976745","pmid":"https://pubmed.ncbi.nlm.nih.gov/19123644"},"language":"en","primary_location":{"id":"doi:10.1117/1.3037341","doi":"https://doi.org/10.1117/1.3037341","is_oa":true,"landing_page_url":"https://doi.org/10.1117/1.3037341","pdf_url":"https://www.spiedigitallibrary.org/journals/journal-of-biomedical-optics/volume-13/issue-6/060503/Polarization-effect-on-the-depth-resolution-of-optical-coherence-tomography/10.1117/1.3037341.pdf","source":{"id":"https://openalex.org/S117354312","display_name":"Journal of Biomedical Optics","issn_l":"1083-3668","issn":["1083-3668","1560-2281"],"is_oa":false,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","doyens","jufo-2","ki-jl-2","medline","norway-2"],"host_organization":"https://openalex.org/P4310315543","host_organization_name":"SPIE","host_organization_lineage":["https://openalex.org/P4310315543"],"host_organization_lineage_names":["SPIE"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Biomedical Optics","raw_type":"journal-article"},"volume":null,"type":"article","indexed_in":["crossref","doaj","pubmed"],"open_access":{"is_oa":true,"oa_status":"bronze","oa_url":"https://www.spiedigitallibrary.org/journals/journal-of-biomedical-optics/volume-13/issue-6/060503/Polarization-effect-on-the-depth-resolution-of-optical-coherence-tomography/10.1117/1.3037341.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5075254066","display_name":"Shuliang Jiao","orcid":"https://orcid.org/0000-0003-3690-3722","observed_orcids":["https://orcid.org/0000-0003-3690-3722"]},"institutions":[{"id":"https://openalex.org/I145608581","display_name":"University of Miami","ror":"https://ror.org/02dgjyy92","country_code":"US","type":"education","lineage":["https://openalex.org/I145608581"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Shuliang Jiao","raw_affiliation_strings":["Univ. of Miami School of Medicine","University of Miami Miller School of Medicine, Bascom Palmer Eye Institute, 1638 NW 10th Ave., Miami, Florida 33136, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Univ. of Miami School of Medicine","institution_ids":["https://openalex.org/I145608581"]},{"raw_affiliation_string":"University of Miami Miller School of Medicine, Bascom Palmer Eye Institute, 1638 NW 10th Ave., Miami, Florida 33136, USA","institution_ids":["https://openalex.org/I145608581"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5056630421","display_name":"Marco Ruggeri","orcid":"https://orcid.org/0000-0001-6491-8476","observed_orcids":["https://orcid.org/0000-0001-6491-8476"]},"institutions":[{"id":"https://openalex.org/I145608581","display_name":"University of Miami","ror":"https://ror.org/02dgjyy92","country_code":"US","type":"education","lineage":["https://openalex.org/I145608581"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Marco Ruggeri","raw_affiliation_strings":["Univ. of Miami School of Medicine","University of Miami Miller School of Medicine, Bascom Palmer Eye Institute, 1638 NW 10th Ave., Miami, Florida 33136"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Univ. of Miami School of Medicine","institution_ids":["https://openalex.org/I145608581"]},{"raw_affiliation_string":"University of Miami Miller School of Medicine, Bascom Palmer Eye Institute, 1638 NW 10th Ave., Miami, Florida 33136","institution_ids":["https://openalex.org/I145608581"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I145608581"],"apc_list":{"value":1675,"currency":"USD","value_usd":1675},"apc_paid":null,"fwci":0.4261,"has_fulltext":true,"cited_by_count":23,"citation_normalized_percentile":{"value":0.67733545,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":97},"biblio":{"volume":"13","issue":"06","first_page":"1","last_page":"3"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11569","display_name":"Optical Coherence Tomography Applications","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11569","display_name":"Optical Coherence Tomography Applications","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11484","display_name":"Adaptive optics and wavefront sensing","score":0.0,"subfield":{"id":"https://openalex.org/subfields/3107","display_name":"Atomic and Molecular Physics, and Optics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12050","display_name":"Optical Polarization and Ellipsometry","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/optical-coherence-tomography","display_name":"optical coherence tomography","score":0.9409999847412109},{"id":"https://openalex.org/keywords/depth-resolution","display_name":"depth resolution","score":0.8460000157356262},{"id":"https://openalex.org/keywords/polarization-mismatch","display_name":"polarization mismatch","score":0.9739999771118164},{"id":"https://openalex.org/keywords/point-spread-function","display_name":"point spread function","score":0.6779999732971191},{"id":"https://openalex.org/keywords/degree-of-polarization","display_name":"degree of polarization","score":0.8460000157356262},{"id":"https://openalex.org/keywords/partially-polarized-light","display_name":"partially polarized light","score":0.8629999756813049},{"id":"https://openalex.org/keywords/birefringence","display_name":"birefringence","score":0.7820000052452087},{"id":"https://openalex.org/keywords/light-scattering","display_name":"light scattering","score":0.6859999895095825},{"id":"https://openalex.org/keywords/polarization-controller","display_name":"polarization controller","score":0.5730000138282776},{"id":"https://openalex.org/keywords/tissue-imaging","display_name":"tissue imaging","score":0.8679999709129333}],"concepts":[{"id":"https://openalex.org/C2778818243","wikidata":"https://www.wikidata.org/wiki/Q899552","display_name":"Optical coherence tomography","level":2,"score":0.7985782623291016},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.7972117066383362},{"id":"https://openalex.org/C121524040","wikidata":"https://www.wikidata.org/wiki/Q11942175","display_name":"Polarizer","level":3,"score":0.6721954941749573},{"id":"https://openalex.org/C205049153","wikidata":"https://www.wikidata.org/wiki/Q2698605","display_name":"Polarization (electrochemistry)","level":2,"score":0.6546446084976196},{"id":"https://openalex.org/C125743686","wikidata":"https://www.wikidata.org/wiki/Q108779","display_name":"Birefringence","level":2,"score":0.5758081674575806},{"id":"https://openalex.org/C205372480","wikidata":"https://www.wikidata.org/wiki/Q210521","display_name":"Image resolution","level":2,"score":0.49148380756378174},{"id":"https://openalex.org/C194118358","wikidata":"https://www.wikidata.org/wiki/Q5251843","display_name":"Degree of polarization","level":3,"score":0.47506946325302124},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.3972527086734772},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.3804561197757721},{"id":"https://openalex.org/C191486275","wikidata":"https://www.wikidata.org/wiki/Q210028","display_name":"Scattering","level":2,"score":0.36045342683792114},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.11723288893699646},{"id":"https://openalex.org/C147789679","wikidata":"https://www.wikidata.org/wiki/Q11372","display_name":"Physical chemistry","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007090","descriptor_name":"Image Interpretation, Computer-Assisted","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D007090","descriptor_name":"Image Interpretation, Computer-Assisted","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D007090","descriptor_name":"Image Interpretation, Computer-Assisted","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D007090","descriptor_name":"Image Interpretation, Computer-Assisted","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D012031","descriptor_name":"Refractometry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D012031","descriptor_name":"Refractometry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D012031","descriptor_name":"Refractometry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D012031","descriptor_name":"Refractometry","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D012031","descriptor_name":"Refractometry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D012031","descriptor_name":"Refractometry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D012031","descriptor_name":"Refractometry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D012031","descriptor_name":"Refractometry","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D016477","descriptor_name":"Artifacts","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D016477","descriptor_name":"Artifacts","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D016477","descriptor_name":"Artifacts","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D016477","descriptor_name":"Artifacts","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D017076","descriptor_name":"Computer-Aided Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017076","descriptor_name":"Computer-Aided Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017076","descriptor_name":"Computer-Aided Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017076","descriptor_name":"Computer-Aided Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D021621","descriptor_name":"Imaging, Three-Dimensional","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D021621","descriptor_name":"Imaging, Three-Dimensional","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D021621","descriptor_name":"Imaging, Three-Dimensional","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D021621","descriptor_name":"Imaging, Three-Dimensional","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D021621","descriptor_name":"Imaging, Three-Dimensional","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D021621","descriptor_name":"Imaging, Three-Dimensional","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D021621","descriptor_name":"Imaging, Three-Dimensional","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D021621","descriptor_name":"Imaging, Three-Dimensional","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D041623","descriptor_name":"Tomography, Optical Coherence","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D041623","descriptor_name":"Tomography, Optical Coherence","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D041623","descriptor_name":"Tomography, Optical Coherence","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D041623","descriptor_name":"Tomography, Optical Coherence","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D041623","descriptor_name":"Tomography, Optical Coherence","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D041623","descriptor_name":"Tomography, Optical Coherence","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D041623","descriptor_name":"Tomography, Optical Coherence","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D041623","descriptor_name":"Tomography, Optical Coherence","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false}],"locations_count":4,"locations":[{"id":"doi:10.1117/1.3037341","doi":"https://doi.org/10.1117/1.3037341","is_oa":true,"landing_page_url":"https://doi.org/10.1117/1.3037341","pdf_url":"https://www.spiedigitallibrary.org/journals/journal-of-biomedical-optics/volume-13/issue-6/060503/Polarization-effect-on-the-depth-resolution-of-optical-coherence-tomography/10.1117/1.3037341.pdf","source":{"id":"https://openalex.org/S117354312","display_name":"Journal of Biomedical Optics","issn_l":"1083-3668","issn":["1083-3668","1560-2281"],"is_oa":false,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","doyens","jufo-2","ki-jl-2","medline","norway-2"],"host_organization":"https://openalex.org/P4310315543","host_organization_name":"SPIE","host_organization_lineage":["https://openalex.org/P4310315543"],"host_organization_lineage_names":["SPIE"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Biomedical Optics","raw_type":"journal-article"},{"id":"pmid:19123644","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/19123644","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of biomedical optics","raw_type":"Journal Article"},{"id":"pmh:oai:europepmc.org:1492774","doi":null,"is_oa":false,"landing_page_url":"https://www.ncbi.nlm.nih.gov/pmc/articles/2718718","pdf_url":null,"source":{"id":"https://openalex.org/S4306400806","display_name":"Europe PMC (PubMed Central)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1303153112","host_organization_name":"European Bioinformatics Institute","host_organization_lineage":["https://openalex.org/I1303153112"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Text"},{"id":"pmh:oai:pubmedcentral.nih.gov:2718718","doi":null,"is_oa":true,"landing_page_url":"https://www.ncbi.nlm.nih.gov/pmc/articles/2718718","pdf_url":null,"source":{"id":"https://openalex.org/S2764455111","display_name":"PubMed Central","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"J Biomed Opt","raw_type":"Text"}],"best_oa_location":{"id":"doi:10.1117/1.3037341","doi":"https://doi.org/10.1117/1.3037341","is_oa":true,"landing_page_url":"https://doi.org/10.1117/1.3037341","pdf_url":"https://www.spiedigitallibrary.org/journals/journal-of-biomedical-optics/volume-13/issue-6/060503/Polarization-effect-on-the-depth-resolution-of-optical-coherence-tomography/10.1117/1.3037341.pdf","source":{"id":"https://openalex.org/S117354312","display_name":"Journal of Biomedical Optics","issn_l":"1083-3668","issn":["1083-3668","1560-2281"],"is_oa":false,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","doyens","jufo-2","ki-jl-2","medline","norway-2"],"host_organization":"https://openalex.org/P4310315543","host_organization_name":"SPIE","host_organization_lineage":["https://openalex.org/P4310315543"],"host_organization_lineage_names":["SPIE"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Biomedical Optics","raw_type":"journal-article"},"sustainable_development_goals":[],"sustainable_development_goals_aurora":[],"study_designs":[],"awards":[{"id":"https://openalex.org/G5519869620","display_name":"Ophthalmic imaging of small animal models of ocular diseases","funder_award_id":"1r21eb008800-01","funder_id":"https://openalex.org/F4320332161","funder_display_name":"National Institutes of Health"},{"id":"https://openalex.org/G654984417","display_name":null,"funder_award_id":"1R21 EB008800-01","funder_id":"https://openalex.org/F4320337363","funder_display_name":"National Institute of Biomedical Imaging and Bioengineering"},{"id":"https://openalex.org/G8871024024","display_name":null,"funder_award_id":"R21 EB008800","funder_id":"https://openalex.org/F4320337363","funder_display_name":"National Institute of Biomedical Imaging and Bioengineering"}],"funders":[{"id":"https://openalex.org/F4320332161","display_name":"National Institutes of Health","ror":"https://ror.org/01cwqze88"},{"id":"https://openalex.org/F4320337363","display_name":"National Institute of Biomedical Imaging and Bioengineering","ror":"https://ror.org/00372qc85"}],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2094976745.pdf","grobid_xml":"https://content.openalex.org/works/W2094976745.grobid-xml"},"referenced_works_count":9,"referenced_works":["https://openalex.org/W1834839393","https://openalex.org/W1978054881","https://openalex.org/W1980995190","https://openalex.org/W2020312196","https://openalex.org/W2096412116","https://openalex.org/W2096516121","https://openalex.org/W2141091829","https://openalex.org/W2164607765","https://openalex.org/W2418802570"],"related_works":["https://openalex.org/W2154191047","https://openalex.org/W2388067771","https://openalex.org/W1798892010","https://openalex.org/W2047305093","https://openalex.org/W2783430448","https://openalex.org/W2033696175","https://openalex.org/W4360611777","https://openalex.org/W4229935931","https://openalex.org/W2011629624","https://openalex.org/W2034902229"],"abstract_inverted_index":{"We":[0],"find":[1],"for":[2,114],"the":[3,10,29,36,40,45,55,64,71,79,85,92,100,106,123,136,144,155,162,169],"first":[4],"time":[5],"that":[6,70],"polarization":[7,37,60,95,107,139,156],"mismatch":[8],"of":[9,39,94,105,118,158,171],"sample":[11,153,173],"and":[12,99],"reference":[13],"arms":[14,42],"in":[15,135,151],"optical-fiber-based":[16],"optical":[17],"coherence":[18],"tomography":[19],"(OCT)":[20],"has":[21,111],"critical":[22],"effect":[23],"on":[24],"its":[25],"depth":[26,72,101,124,145,150,170],"resolution":[27,73,102,125,146,167],"when":[28],"light":[30,87,159],"source":[31,86],"is":[32,51,74,97],"partially":[33],"polarized.":[34],"When":[35,58,82,164],"states":[38,61],"two":[41],"are":[43,62],"matched,":[44],"measured":[46],"point":[47],"spread":[48],"function":[49],"(PSF)":[50],"almost":[52],"identical":[53],"to":[54,76],"theoretical":[56,80],"prediction.":[57],"their":[59],"mismatched,":[63],"PSF":[65],"can":[66,126,141,174],"be":[67,127,175],"so":[68],"distorted":[69],"degraded":[75,129],"several":[77],"times":[78],"value.":[81],"we":[83],"polarize":[84],"with":[88],"a":[89,148,152,172],"polarizer,":[90],"then":[91],"degree":[93],"(DOP)":[96],"unity,":[98],"becomes":[103],"independent":[104],"mismatch.":[108],"This":[109],"discovery":[110],"fundamental":[112],"importance":[113],"high-resolution":[115],"OCT":[116],"imaging":[117],"biological":[119],"tissues.":[120],"With":[121],"DOP<1,":[122],"quickly":[128],"by":[130],"either":[131],"birefringence":[132],"or":[133],"scattering":[134],"sample.":[137],"Adjusting":[138],"controllers":[140],"only":[142],"improve":[143],"at":[147],"certain":[149],"if":[154],"state":[157],"changes":[160],"along":[161,168],"depth.":[163],"DOP=1,":[165],"uniform":[166],"achieved.":[176]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":3},{"year":2023,"cited_by_count":3},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":3},{"year":2018,"cited_by_count":3},{"year":2017,"cited_by_count":3},{"year":2012,"cited_by_count":2}],"updated_date":"2026-09-29T14:09:16.559479","created_date":"2025-10-10T00:00:00"}
