{"id":"https://openalex.org/W2093352196","doi":"https://doi.org/10.1109/tgrs.2009.2017015","title":"Measurements on Active Cold Loads for Radiometer Calibration","display_name":"Measurements on Active Cold Loads for Radiometer Calibration","publication_year":2009,"publication_date":"2009-05-04","ids":{"openalex":"https://openalex.org/W2093352196","doi":"https://doi.org/10.1109/tgrs.2009.2017015","mag":"2093352196"},"language":"en","primary_location":{"id":"doi:10.1109/tgrs.2009.2017015","doi":"https://doi.org/10.1109/tgrs.2009.2017015","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tgrs.2009.2017015","pdf_url":null,"source":{"id":"https://openalex.org/S111326731","display_name":"IEEE Transactions on Geoscience and Remote Sensing","issn_l":"0196-2892","issn":["0196-2892","1558-0644"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","ccf-b","cwts-core","dongbi-b","jufo-3","norway-2","poland-200","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Geoscience and Remote Sensing","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5082053393","display_name":"Sten Schmidl S\u00f8bj\u00e6rg","orcid":"https://orcid.org/0000-0001-6914-8597","observed_orcids":["https://orcid.org/0000-0001-6914-8597"]},"institutions":[{"id":"https://openalex.org/I96673099","display_name":"Technical University of Denmark","ror":"https://ror.org/04qtj9h94","country_code":"DK","type":"education","lineage":["https://openalex.org/I96673099"]}],"countries":["DK"],"is_corresponding":false,"raw_author_name":"S.S. Sobjaerg","raw_affiliation_strings":["Microwave Remote Sensing Section, National Space Institute, Technical University of Denmark, Lyngby, Denmark","Microwave Remote Sensing Sect., Tech. Univ. of Denmark (DTU), Lyngby, Denmark"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Microwave Remote Sensing Section, National Space Institute, Technical University of Denmark, Lyngby, Denmark","institution_ids":["https://openalex.org/I96673099"]},{"raw_affiliation_string":"Microwave Remote Sensing Sect., Tech. Univ. of Denmark (DTU), Lyngby, Denmark","institution_ids":["https://openalex.org/I96673099"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5044545816","display_name":"Niels Skou","orcid":"https://orcid.org/0000-0002-7245-017X","observed_orcids":["https://orcid.org/0000-0002-7245-017X"]},"institutions":[{"id":"https://openalex.org/I96673099","display_name":"Technical University of Denmark","ror":"https://ror.org/04qtj9h94","country_code":"DK","type":"education","lineage":["https://openalex.org/I96673099"]}],"countries":["DK"],"is_corresponding":false,"raw_author_name":"N. Skou","raw_affiliation_strings":["Microwave Remote Sensing Section National Space Institute, Technical University of Denmark, Lyngby, Denmark","Microwave Remote Sensing Sect., Tech. Univ. of Denmark (DTU), Lyngby, Denmark"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Microwave Remote Sensing Section National Space Institute, Technical University of Denmark, Lyngby, Denmark","institution_ids":["https://openalex.org/I96673099"]},{"raw_affiliation_string":"Microwave Remote Sensing Sect., Tech. Univ. of Denmark (DTU), Lyngby, Denmark","institution_ids":["https://openalex.org/I96673099"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5089329629","display_name":"Jan E. Balling","orcid":"https://orcid.org/0000-0002-3685-2294","observed_orcids":["https://orcid.org/0000-0002-3685-2294"]},"institutions":[{"id":"https://openalex.org/I96673099","display_name":"Technical University of Denmark","ror":"https://ror.org/04qtj9h94","country_code":"DK","type":"education","lineage":["https://openalex.org/I96673099"]}],"countries":["DK"],"is_corresponding":false,"raw_author_name":"J.E. Balling","raw_affiliation_strings":["Microwave Remote Sensing Section National Space Institute, Technical University of Denmark, Lyngby, Denmark","Microwave Remote Sensing Sect., Tech. Univ. of Denmark (DTU), Lyngby, Denmark"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Microwave Remote Sensing Section National Space Institute, Technical University of Denmark, Lyngby, Denmark","institution_ids":["https://openalex.org/I96673099"]},{"raw_affiliation_string":"Microwave Remote Sensing Sect., Tech. Univ. of Denmark (DTU), Lyngby, Denmark","institution_ids":["https://openalex.org/I96673099"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I96673099"],"apc_list":{"value":2645,"currency":"USD","value_usd":2645},"apc_paid":null,"fwci":6.2373,"has_fulltext":false,"cited_by_count":23,"citation_normalized_percentile":{"value":0.95555468,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":88,"max":97},"biblio":{"volume":"47","issue":"9","first_page":"3134","last_page":"3139"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12019","display_name":"Calibration and Measurement Techniques","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2202","display_name":"Aerospace Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12019","display_name":"Calibration and Measurement Techniques","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2202","display_name":"Aerospace Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11607","display_name":"Microwave and Dielectric Measurement Techniques","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13928","display_name":"Advanced Sensor Technologies Research","score":0.0,"subfield":{"id":"https://openalex.org/subfields/3105","display_name":"Instrumentation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/radiometer-calibration","display_name":"radiometer calibration","score":0.8690000176429749},{"id":"https://openalex.org/keywords/spaceborne-microwave-radiometer","display_name":"spaceborne microwave radiometer","score":0.8629999756813049},{"id":"https://openalex.org/keywords/x-band","display_name":"X-band","score":0.9079999923706055},{"id":"https://openalex.org/keywords/noise-temperature","display_name":"noise temperature","score":0.7429999709129333},{"id":"https://openalex.org/keywords/long-term-stability","display_name":"long-term stability","score":0.800000011920929},{"id":"https://openalex.org/keywords/temperature-response","display_name":"temperature sensitivity","score":0.8920000195503235}],"concepts":[{"id":"https://openalex.org/C120189094","wikidata":"https://www.wikidata.org/wiki/Q850281","display_name":"Radiometer","level":2,"score":0.8616533279418945},{"id":"https://openalex.org/C62649853","wikidata":"https://www.wikidata.org/wiki/Q199687","display_name":"Remote sensing","level":1,"score":0.6523852348327637},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.6266952753067017},{"id":"https://openalex.org/C96960616","wikidata":"https://www.wikidata.org/wiki/Q3814470","display_name":"Microwave radiometer","level":3,"score":0.5865705013275146},{"id":"https://openalex.org/C87456703","wikidata":"https://www.wikidata.org/wiki/Q247760","display_name":"Radiometry","level":2,"score":0.5805782675743103},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.5799216032028198},{"id":"https://openalex.org/C72293138","wikidata":"https://www.wikidata.org/wiki/Q909741","display_name":"Temperature measurement","level":2,"score":0.5369662046432495},{"id":"https://openalex.org/C99498987","wikidata":"https://www.wikidata.org/wiki/Q2210247","display_name":"Noise (video)","level":3,"score":0.5113353133201599},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.4591706395149231},{"id":"https://openalex.org/C112972136","wikidata":"https://www.wikidata.org/wiki/Q7595718","display_name":"Stability (learning theory)","level":2,"score":0.45344194769859314},{"id":"https://openalex.org/C44838205","wikidata":"https://www.wikidata.org/wiki/Q127995","display_name":"Microwave","level":2,"score":0.4216269552707672},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.3802347183227539},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.3739745020866394},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.3301244080066681},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.2242027223110199},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.17851969599723816},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.1633405089378357},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.13202059268951416},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.11853224039077759},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.11228743195533752},{"id":"https://openalex.org/C115961682","wikidata":"https://www.wikidata.org/wiki/Q860623","display_name":"Image (mathematics)","level":2,"score":0.0},{"id":"https://openalex.org/C119857082","wikidata":"https://www.wikidata.org/wiki/Q2539","display_name":"Machine learning","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/tgrs.2009.2017015","doi":"https://doi.org/10.1109/tgrs.2009.2017015","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tgrs.2009.2017015","pdf_url":null,"source":{"id":"https://openalex.org/S111326731","display_name":"IEEE Transactions on Geoscience and Remote Sensing","issn_l":"0196-2892","issn":["0196-2892","1558-0644"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","ccf-b","cwts-core","dongbi-b","jufo-3","norway-2","poland-200","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Geoscience and Remote Sensing","raw_type":"journal-article"},{"id":"pmh:oai:pure.atira.dk:publications/cc01a953-0641-4cbb-aac8-0b4b6c4818f4","doi":null,"is_oa":false,"landing_page_url":"https://orbit.dtu.dk/en/publications/cc01a953-0641-4cbb-aac8-0b4b6c4818f4","pdf_url":null,"source":{"id":"https://openalex.org/S4306400705","display_name":"Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I96673099","host_organization_name":"Technical University of Denmark","host_organization_lineage":["https://openalex.org/I96673099"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"S\u00f8bj\u00e6rg , S S , Skou , N &amp; Balling , J E 2009 , ' Measurements on Active Cold Loads for Radiometer Calibration ' , I E E E Transactions on Geoscience and Remote Sensing , vol. 47 , no. 9 , pp. 3134-3139 . https://doi.org/10.1109/TGRS.2009.2017015","raw_type":"article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W1637248278","https://openalex.org/W1987841468","https://openalex.org/W2055077593","https://openalex.org/W2142809818"],"related_works":["https://openalex.org/W2104960315","https://openalex.org/W1999104107","https://openalex.org/W2037363304","https://openalex.org/W2052551083","https://openalex.org/W2030263016","https://openalex.org/W1993963441","https://openalex.org/W2460267318","https://openalex.org/W2782378294","https://openalex.org/W7099878125","https://openalex.org/W2144747470"],"abstract_inverted_index":{"Two":[0],"semiconductor":[1],"active":[2],"cold":[3,10],"loads":[4],"(ACLs)":[5],"to":[6],"be":[7],"used":[8],"as":[9],"references":[11],"in":[12,31,39],"spaceborne":[13],"microwave":[14],"radiometers":[15],"have":[16],"been":[17,58],"developed.":[18,59],"An":[19],"X-band":[20],"frequency":[21],"was":[22,30],"chosen,":[23],"and":[24,46,68,71,80,89,107],"the":[25,32,40,93,105],"target":[26],"noise":[27],"temperature":[28,42,97],"value":[29],"50-100-K":[33],"range.":[34],"The":[35,75,96],"ACLs":[36],"are":[37,73],"characterized":[38],"operating":[41],"range":[43],"of":[44,87],"0degC-50degC,":[45],"long-term":[47,108],"stability":[48,109],"is":[49,63,78,99,113],"assessed.":[50],"To":[51],"this":[52],"end,":[53],"a":[54,65],"test":[55,61,76,81],"bed":[56,62],"has":[57],"This":[60],"actually":[64],"stable":[66],"radiometer,":[67],"its":[69],"design":[70],"performance":[72],"discussed.":[74],"setup":[77],"described,":[79],"campaign":[82],"results":[83],"indicate":[84],"output":[85],"temperatures":[86],"77":[88],"56":[90],"K":[91],"for":[92,104],"two":[94],"ACLs.":[95],"sensitivity":[98],"slightly":[100],"below":[101],"0.4":[102],"K/degC":[103],"units,":[106],"within":[110],"2":[111],"K/year":[112],"observed.":[114]},"counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2020,"cited_by_count":2},{"year":2017,"cited_by_count":3},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":2},{"year":2013,"cited_by_count":1},{"year":2012,"cited_by_count":3}],"updated_date":"2026-11-07T11:25:07.637180","created_date":"2016-06-24T00:00:00"}
