{"id":"https://openalex.org/W209100905","doi":"https://doi.org/10.21236/ada538133","title":"Increased Efficiency Thermoelectric Generator With Convective Heat Transport","display_name":"Increased Efficiency Thermoelectric Generator With Convective Heat Transport","publication_year":2011,"publication_date":"2011-02-25","ids":{"openalex":"https://openalex.org/W209100905","doi":"https://doi.org/10.21236/ada538133","mag":"209100905"},"language":"en","primary_location":{"id":"doi:10.21236/ada538133","doi":"https://doi.org/10.21236/ada538133","is_oa":false,"landing_page_url":"https://doi.org/10.21236/ada538133","pdf_url":null,"source":{"id":"https://openalex.org/S4406923043","display_name":"Defense Technical Information Center (DTIC)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"US Dept of the Navy","raw_type":"report"},"volume":null,"type":"report","is_traditional":false,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5024890122","display_name":"Lon E. Bell","orcid":"https://orcid.org/0000-0001-6346-8039","observed_orcids":["https://orcid.org/0000-0001-6346-8039"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Lon E. Bell","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5057211981","display_name":"Ramesh Koripella","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Ramesh Koripella","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":null,"display_name":"Robert T. Collins","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Robert T. Collins","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10440","display_name":"Advanced Thermoelectric Materials and Devices","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10440","display_name":"Advanced Thermoelectric Materials and Devices","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14327","display_name":"Advanced Energy Technologies and Civil Engineering Innovations","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2104","display_name":"Nuclear Energy and Engineering"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12139","display_name":"Advanced Thermodynamic Systems and Engines","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/thermoelectric-generators","display_name":"thermoelectric generators","score":0.9309999942779541},{"id":"https://openalex.org/keywords/convective-heat-transfer","display_name":"convective heat transfer","score":0.9480000138282776},{"id":"https://openalex.org/keywords/thermoelectric-efficiency","display_name":"thermoelectric efficiency","score":0.8679999709129333},{"id":"https://openalex.org/keywords/nanostructured-thermoelectric-materials","display_name":"nanostructured thermoelectrics","score":0.8859999775886536},{"id":"https://openalex.org/keywords/waste-heat-recovery","display_name":"waste heat recovery","score":0.8420000076293945}],"concepts":[{"id":"https://openalex.org/C117127486","wikidata":"https://www.wikidata.org/wiki/Q11569191","display_name":"Thermoelectric generator","level":3,"score":0.8489543795585632},{"id":"https://openalex.org/C10899652","wikidata":"https://www.wikidata.org/wiki/Q160329","display_name":"Convection","level":2,"score":0.654629111289978},{"id":"https://openalex.org/C2780992000","wikidata":"https://www.wikidata.org/wiki/Q17016113","display_name":"Generator (circuit theory)","level":3,"score":0.6086113452911377},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5939481258392334},{"id":"https://openalex.org/C41231900","wikidata":"https://www.wikidata.org/wiki/Q918227","display_name":"Convective heat transfer","level":3,"score":0.5750131607055664},{"id":"https://openalex.org/C63024428","wikidata":"https://www.wikidata.org/wiki/Q552456","display_name":"Thermoelectric effect","level":2,"score":0.5520249009132385},{"id":"https://openalex.org/C50517652","wikidata":"https://www.wikidata.org/wiki/Q179635","display_name":"Heat transfer","level":2,"score":0.44394388794898987},{"id":"https://openalex.org/C116915560","wikidata":"https://www.wikidata.org/wiki/Q83504","display_name":"Nuclear engineering","level":1,"score":0.4395948648452759},{"id":"https://openalex.org/C207365445","wikidata":"https://www.wikidata.org/wiki/Q15020929","display_name":"Thermoelectric materials","level":3,"score":0.43792280554771423},{"id":"https://openalex.org/C128458982","wikidata":"https://www.wikidata.org/wiki/Q18891486","display_name":"Thermoelectric cooling","level":3,"score":0.42960065603256226},{"id":"https://openalex.org/C108225325","wikidata":"https://www.wikidata.org/wiki/Q11456","display_name":"Semiconductor","level":2,"score":0.4214513897895813},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.3403382897377014},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.33549967408180237},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.32016521692276},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.2792540192604065},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.2146349847316742},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.17971748113632202},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.15728315711021423},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.12024903297424316}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.21236/ada538133","doi":"https://doi.org/10.21236/ada538133","is_oa":false,"landing_page_url":"https://doi.org/10.21236/ada538133","pdf_url":null,"source":{"id":"https://openalex.org/S4406923043","display_name":"Defense Technical Information Center (DTIC)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"US Dept of the Navy","raw_type":"report"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.9853000044822693,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2137536495","https://openalex.org/W4385142818","https://openalex.org/W2898850962","https://openalex.org/W4392203715","https://openalex.org/W2063098567","https://openalex.org/W7159740443","https://openalex.org/W2909888365","https://openalex.org/W2991740009","https://openalex.org/W7217708324","https://openalex.org/W2558331605"],"abstract_inverted_index":{"Abstract":[0],":":[1],"A":[2],"novel":[3],"approach":[4],"for":[5,59,102,115,129],"increasing":[6],"the":[7,21,25,41,69,87,91],"system-level":[8],"efficiency":[9,92],"of":[10,24,44,68,93],"a":[11],"thermoelectric":[12,124],"generator":[13,26,130],"(TEG)":[14],"by":[15,85,98,111],"utilizing":[16],"convective":[17,70,88,146],"heat":[18,89],"transfer":[19,90],"from":[20,137],"cold":[22],"side":[23],"to":[27,39,77,100,113,144],"hot":[28],"one":[29],"will":[30,36,50,62,72,126,141],"be":[31,37,51,63,73,96,127,142],"explored.":[32],"Existing":[33],"theoretical":[34],"framework":[35],"expanded":[38],"include":[40],"physical":[42],"detail":[43],"concrete":[45],"experimental":[46],"systems.":[47],"Demonstration":[48],"devices":[49],"designed":[52],"and":[53,56,75,110,122],"built.":[54],"Test":[55],"measurement":[57],"setup":[58],"model":[60],"validation":[61],"constructed.":[64],"Power":[65],"generation":[66],"efficiencies":[67],"TEG":[71,94,147],"measured":[74],"compared":[76],"operation":[78],"without":[79],"convection.":[80],"It":[81],"is":[82],"expected":[83],"that":[84],"using":[86],"can":[95],"increased":[97],"12%":[99],"18%":[101,112],"metallic":[103],"TE":[104,119,135],"elements,":[105],"such":[106],"as":[107],"copper-constantane":[108],"couples,":[109],"32%":[114],"higher":[116],"performance":[117],"semiconductor":[118],"materials.":[120],"Conventional":[121],"advanced":[123],"materials":[125,136],"used":[128,143],"construction.":[131],"Thick":[132],"film":[133],"nanostructured":[134],"UCSB":[138],"and/or":[139],"MIT/LL":[140],"construct":[145],"modules":[148],"if":[149],"they":[150],"become":[151],"available.":[152]},"counts_by_year":[],"updated_date":"2026-11-06T12:05:46.655746","created_date":"2016-06-24T00:00:00"}
