{"id":"https://openalex.org/W2089678778","doi":"https://doi.org/10.1177/014362449501600401","title":"Thermal performance lines of chiller plants of two institutional buildings in Hong Kong","display_name":"Thermal performance lines of chiller plants of two institutional buildings in Hong Kong","publication_year":1995,"publication_date":"1995-11-01","ids":{"openalex":"https://openalex.org/W2089678778","doi":"https://doi.org/10.1177/014362449501600401","mag":"2089678778"},"language":"en","primary_location":{"id":"doi:10.1177/014362449501600401","doi":"https://doi.org/10.1177/014362449501600401","is_oa":false,"landing_page_url":"https://doi.org/10.1177/014362449501600401","pdf_url":null,"source":{"id":"https://openalex.org/S146335943","display_name":"Building Services Engineering Research and Technology","issn_l":"0143-6244","issn":["0143-6244","1477-0849"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-c","jufo-1","norway-1","poland-100","russia-white-list-2"],"host_organization":"https://openalex.org/P4310320017","host_organization_name":"SAGE Publishing","host_organization_lineage":["https://openalex.org/P4310320017"],"host_organization_lineage_names":["SAGE Publishing"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Building Services Engineering Research and Technology","raw_type":"journal-article"},"volume":null,"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5109004161","display_name":"Francis W. H. Yik","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I14243506","display_name":"Hong Kong Polytechnic University","ror":"https://ror.org/0030zas98","country_code":"HK","type":"education","lineage":["https://openalex.org/I14243506"]}],"countries":["HK"],"is_corresponding":false,"raw_author_name":"F W H Yik","raw_affiliation_strings":["Department of Building Services Engineering, Hong Kong Polytechnic University, Hunghom, Kowloon, Hong Kong"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Building Services Engineering, Hong Kong Polytechnic University, Hunghom, Kowloon, Hong Kong","institution_ids":["https://openalex.org/I14243506"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5033024988","display_name":"John Burnett","orcid":"https://orcid.org/0000-0002-8817-6064","observed_orcids":["https://orcid.org/0000-0002-8817-6064"]},"institutions":[{"id":"https://openalex.org/I14243506","display_name":"Hong Kong Polytechnic University","ror":"https://ror.org/0030zas98","country_code":"HK","type":"education","lineage":["https://openalex.org/I14243506"]}],"countries":["HK"],"is_corresponding":false,"raw_author_name":"J. Burnett","raw_affiliation_strings":["Department of Building Services Engineering, Hong Kong Polytechnic University, Hunghom, Kowloon, Hong Kong"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Building Services Engineering, Hong Kong Polytechnic University, Hunghom, Kowloon, Hong Kong","institution_ids":["https://openalex.org/I14243506"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5024913651","display_name":"Hyun-Jae Chang","orcid":"https://orcid.org/0000-0003-1656-900X","observed_orcids":["https://orcid.org/0000-0003-1656-900X"]},"institutions":[{"id":"https://openalex.org/I14243506","display_name":"Hong Kong Polytechnic University","ror":"https://ror.org/0030zas98","country_code":"HK","type":"education","lineage":["https://openalex.org/I14243506"]}],"countries":["HK"],"is_corresponding":false,"raw_author_name":"H.L. Chang","raw_affiliation_strings":["Department of Building Services Engineering, Hong Kong Polytechnic University, Hunghom, Kowloon, Hong Kong"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Building Services Engineering, Hong Kong Polytechnic University, Hunghom, Kowloon, Hong Kong","institution_ids":["https://openalex.org/I14243506"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I14243506"],"apc_list":{"value":4150,"currency":"USD","value_usd":4150},"apc_paid":null,"fwci":3.6594,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.91480489,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":null,"biblio":{"volume":"16","issue":"4","first_page":"169","last_page":"178"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9965999722480774,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9965999722480774,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.002400000113993883,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":0.00019999999494757503,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/chiller-plant","display_name":"chiller plant","score":0.8970000147819519},{"id":"https://openalex.org/keywords/institutional-building","display_name":"institutional building","score":0.6700000166893005},{"id":"https://openalex.org/keywords/energy-audit","display_name":"energy audit","score":0.6740000247955322},{"id":"https://openalex.org/keywords/meteorological-variables","display_name":"meteorological parameters","score":0.5440000295639038},{"id":"https://openalex.org/keywords/energy-performance-of-buildings","display_name":"building energy performance","score":0.47099998593330383}],"concepts":[{"id":"https://openalex.org/C4638862","wikidata":"https://www.wikidata.org/wiki/Q1501558","display_name":"Chiller","level":2,"score":0.8199927806854248},{"id":"https://openalex.org/C27574286","wikidata":"https://www.wikidata.org/wiki/Q320723","display_name":"Variables","level":2,"score":0.6168695688247681},{"id":"https://openalex.org/C48921125","wikidata":"https://www.wikidata.org/wiki/Q10861030","display_name":"Linear regression","level":2,"score":0.5883099436759949},{"id":"https://openalex.org/C152877465","wikidata":"https://www.wikidata.org/wiki/Q208042","display_name":"Regression analysis","level":2,"score":0.5413119792938232},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.4845389723777771},{"id":"https://openalex.org/C133913538","wikidata":"https://www.wikidata.org/wiki/Q774514","display_name":"Thermal comfort","level":2,"score":0.47791773080825806},{"id":"https://openalex.org/C196083921","wikidata":"https://www.wikidata.org/wiki/Q7915758","display_name":"Variance (accounting)","level":2,"score":0.4484364092350006},{"id":"https://openalex.org/C153240184","wikidata":"https://www.wikidata.org/wiki/Q3243772","display_name":"Control variable","level":2,"score":0.4471651017665863},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.44171959161758423},{"id":"https://openalex.org/C149782125","wikidata":"https://www.wikidata.org/wiki/Q160039","display_name":"Econometrics","level":1,"score":0.4154092073440552},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.3489624857902527},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3348572850227356},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.19755858182907104},{"id":"https://openalex.org/C162324750","wikidata":"https://www.wikidata.org/wiki/Q8134","display_name":"Economics","level":0,"score":0.12142524123191833},{"id":"https://openalex.org/C205649164","wikidata":"https://www.wikidata.org/wiki/Q1071","display_name":"Geography","level":0,"score":0.10634434223175049},{"id":"https://openalex.org/C121955636","wikidata":"https://www.wikidata.org/wiki/Q4116214","display_name":"Accounting","level":1,"score":0.08985581994056702},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1177/014362449501600401","doi":"https://doi.org/10.1177/014362449501600401","is_oa":false,"landing_page_url":"https://doi.org/10.1177/014362449501600401","pdf_url":null,"source":{"id":"https://openalex.org/S146335943","display_name":"Building Services Engineering Research and Technology","issn_l":"0143-6244","issn":["0143-6244","1477-0849"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-c","jufo-1","norway-1","poland-100","russia-white-list-2"],"host_organization":"https://openalex.org/P4310320017","host_organization_name":"SAGE Publishing","host_organization_lineage":["https://openalex.org/P4310320017"],"host_organization_lineage_names":["SAGE Publishing"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Building Services Engineering Research and Technology","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W143527859","https://openalex.org/W1484029254","https://openalex.org/W1586132145","https://openalex.org/W1982368083","https://openalex.org/W1993820999","https://openalex.org/W1994081186","https://openalex.org/W2009537931","https://openalex.org/W2055411905","https://openalex.org/W2797532987","https://openalex.org/W4302437350"],"related_works":["https://openalex.org/W2075325405","https://openalex.org/W2047995165","https://openalex.org/W2588129426","https://openalex.org/W2018972999","https://openalex.org/W2187779445","https://openalex.org/W2769673999","https://openalex.org/W4408112974","https://openalex.org/W3011215615","https://openalex.org/W2033802612","https://openalex.org/W1850734481"],"abstract_inverted_index":{"Chiller":[0],"plant":[1],"electricity":[2],"consumption":[3],"of":[4,79,103,118,129,164,168],"two":[5,30,91],"institutional":[6],"buildings":[7],"have":[8],"been":[9],"audited":[10],"and":[11,17,42,82,108,127,166],"to":[12,49,114],"identify":[13],"potential":[14],"problem":[15],"areas":[16],"establish":[18],"a":[19,97,150,158,169],"basis":[20],"for":[21,28,55,73,89],"assessing":[22],"improvement":[23],"measures,":[24],"thermal":[25,151],"performance":[26,63,152],"lines":[27],"the":[29,51,58,62,87,90,101,119,125,130,138,145,162],"plants":[31],"were":[32,47],"derived":[33],"using":[34],"multiple":[35],"linear":[36],"regression":[37,40,139],"methods.":[38],"Stepping":[39],"methods":[41],"variance":[43],"inflation":[44],"factor":[45],"analysis":[46],"used":[48,72,156],"select":[50],"significant":[52],"weather":[53],"parameters":[54],"use":[56],"as":[57,157],"independent":[59,80,99],"variables":[60,81],"in":[61,86,144],"line":[64,153],"models.":[65],"This":[66],"yielded":[67],"models":[68,88,120,131],"that":[69,149],"cannot":[70],"be":[71,155],"inter-building":[74],"comparison":[75],"because":[76],"different":[77],"combinations":[78],"coefficients":[83],"are":[84],"involved":[85],"plants.":[92,116],"Another":[93],"model":[94],"equation":[95],"with":[96,141],"single":[98],"variable,":[100],"product":[102],"daily":[104],"mean":[105],"outdoor":[106],"temperature":[107],"humidity":[109],"ratio,":[110],"was":[111,121],"found":[112],"applicable":[113],"both":[115],"Adequacy":[117],"verified":[122,132],"by":[123,133],"examining":[124],"residuals":[126],"validity":[128],"data":[134],"splitting":[135],"method.":[136],"Comparing":[137],"statistics":[140],"observations":[142],"made":[143],"energy":[146],"audits":[147],"shows":[148],"may":[154],"diagnostics":[159],"tool":[160],"on":[161],"quality":[163],"control":[165],"operation":[167],"chiller":[170],"plant.":[171]},"counts_by_year":[],"updated_date":"2026-10-12T09:40:04.860316","created_date":"2016-06-24T00:00:00"}
