{"id":"https://openalex.org/W2088083004","doi":"https://doi.org/10.1109/aieepas.1961.4501169","title":"Safe Clearances and Protection against Shocks during Live-Line Work","display_name":"Safe Clearances and Protection against Shocks during Live-Line Work","alternate_titles":[],"publication_year":1961,"publication_date":"1961-04-01","ids":{"openalex":"https://openalex.org/W2088083004","doi":"https://doi.org/10.1109/aieepas.1961.4501169","mag":"2088083004"},"language":"en","primary_location":{"id":"doi:10.1109/aieepas.1961.4501169","doi":"https://doi.org/10.1109/aieepas.1961.4501169","is_oa":false,"landing_page_url":"https://doi.org/10.1109/aieepas.1961.4501169","pdf_url":null,"source":{"id":"https://openalex.org/S4210198682","display_name":"Transactions of the American Institute of Electrical Engineers Part III Power Apparatus and Systems","issn_l":"0097-2460","issn":["0097-2460","2379-6766"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2088083004"],"child_works_count":0,"pull_notice_works":[],"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"A. Elek","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"A. Elek","raw_affiliation_strings":["Hydro Electric Power Commission of Ontario, Toronto, ONT, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Hydro Electric Power Commission of Ontario, Toronto, ONT, Canada","institution_ids":[]}]},{"author_position":"last","author":{"id":null,"display_name":"J. W. Simpson","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"J. W. Simpson","raw_affiliation_strings":["Hydro Electric Power Commission of Ontario, Toronto, ONT, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Hydro Electric Power Commission of Ontario, Toronto, ONT, Canada","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.7359,"has_fulltext":false,"cited_by_count":7,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.69215979,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":92},"biblio":{"volume":"80","issue":"3","first_page":"897","last_page":"902"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.9833999872207642,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.9833999872207642,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10787","display_name":"Lightning and Electromagnetic Phenomena","score":0.00559999980032444,"subfield":{"id":"https://openalex.org/subfields/1902","display_name":"Atmospheric Science"},"field":{"id":"https://openalex.org/fields/19","display_name":"Earth and Planetary Sciences"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.003100000089034438,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/live-line-work","display_name":"live-line work","score":0.984000027179718},{"id":"https://openalex.org/keywords/transmission-lines","display_name":"transmission lines","score":0.8149999976158142},{"id":"https://openalex.org/keywords/switching-overvoltages","display_name":"switching overvoltages","score":0.9900000095367432},{"id":"https://openalex.org/keywords/safety-factor","display_name":"safety factor","score":0.7670000195503235}],"concepts":[{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.7264989614486694},{"id":"https://openalex.org/C2777831296","wikidata":"https://www.wikidata.org/wiki/Q12518","display_name":"Tower","level":2,"score":0.610071063041687},{"id":"https://openalex.org/C18762648","wikidata":"https://www.wikidata.org/wiki/Q42213","display_name":"Work (physics)","level":2,"score":0.6019889116287231},{"id":"https://openalex.org/C151201525","wikidata":"https://www.wikidata.org/wiki/Q177239","display_name":"Limit (mathematics)","level":2,"score":0.5984703302383423},{"id":"https://openalex.org/C198352243","wikidata":"https://www.wikidata.org/wiki/Q37105","display_name":"Line (geometry)","level":2,"score":0.5967019200325012},{"id":"https://openalex.org/C33441834","wikidata":"https://www.wikidata.org/wiki/Q693004","display_name":"Transmission line","level":2,"score":0.5475555062294006},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5005443096160889},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.49595317244529724},{"id":"https://openalex.org/C154108245","wikidata":"https://www.wikidata.org/wiki/Q287381","display_name":"Surge","level":2,"score":0.43494337797164917},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.42060354351997375},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3626940846443176},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3219950497150421},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.27009275555610657},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.2549740970134735},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.10514193773269653},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/aieepas.1961.4501169","doi":"https://doi.org/10.1109/aieepas.1961.4501169","is_oa":false,"landing_page_url":"https://doi.org/10.1109/aieepas.1961.4501169","pdf_url":null,"source":{"id":"https://openalex.org/S4210198682","display_name":"Transactions of the American Institute of Electrical Engineers Part III Power Apparatus and Systems","issn_l":"0097-2460","issn":["0097-2460","2379-6766"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W1565095191","https://openalex.org/W2052605812","https://openalex.org/W2063745403","https://openalex.org/W3215685975"],"related_works":["https://openalex.org/W1978163390","https://openalex.org/W2349927755","https://openalex.org/W2044269436","https://openalex.org/W1998209974","https://openalex.org/W2360424277","https://openalex.org/W2110397977","https://openalex.org/W2356203012","https://openalex.org/W4391557520","https://openalex.org/W2991211506","https://openalex.org/W2378310208"],"abstract_inverted_index":{"An":[0],"equation":[1],"is":[2,32,47,51],"developed":[3],"to":[4,10],"determine":[5],"the":[6,18],"limit":[7],"of":[8,13,28,36],"approach":[9],"live":[11],"parts":[12],"transmission":[14],"lines,":[15],"based":[16],"on":[17,72],"highest":[19],"switching":[20],"surges":[21],"and":[22,49,60],"including":[23],"safety":[24],"factors.":[25],"The":[26,34],"effect":[27],"temporary":[29],"protective":[30],"gaps":[31],"shown.":[33],"mechanism":[35],"shocks":[37,55],"experienced":[38],"by":[39,64],"linemen":[40],"during":[41],"loose":[42],"contact":[43],"with":[44],"a":[45],"tower":[46],"discussed":[48],"it":[50],"concluded":[52],"that":[53],"such":[54],"are":[56],"harmless":[57],"but":[58],"annoying":[59],"can":[61],"be":[62],"eliminated":[63],"introducing":[65],"conducting":[66],"shoes":[67],"for":[68],"live-line":[69],"work,":[70],"especially":[71],"extra-high-voltage":[73],"lines.":[74]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2088083004","counts_by_year":[{"year":2020,"cited_by_count":1}],"updated_date":"2026-10-30T12:39:25.321706","created_date":"2016-06-24T00:00:00"}
