{"id":"https://openalex.org/W2077934603","doi":"https://doi.org/10.1117/1.jbo.19.8.085001","title":"Investigating femtosecond-laser-induced two-photon photoacoustic generation","display_name":"Investigating femtosecond-laser-induced two-photon photoacoustic generation","publication_year":2014,"publication_date":"2014-08-01","ids":{"openalex":"https://openalex.org/W2077934603","doi":"https://doi.org/10.1117/1.jbo.19.8.085001","mag":"2077934603","pmid":"https://pubmed.ncbi.nlm.nih.gov/25084119"},"language":"en","primary_location":{"id":"doi:10.1117/1.jbo.19.8.085001","doi":"https://doi.org/10.1117/1.jbo.19.8.085001","is_oa":true,"landing_page_url":"https://doi.org/10.1117/1.jbo.19.8.085001","pdf_url":"https://www.spiedigitallibrary.org/journals/journal-of-biomedical-optics/volume-19/issue-8/085001/Investigating-femtosecond-laser-induced-two-photon-photoacoustic-generation/10.1117/1.JBO.19.8.085001.pdf","source":{"id":"https://openalex.org/S117354312","display_name":"Journal of Biomedical Optics","issn_l":"1083-3668","issn":["1083-3668","1560-2281"],"is_oa":false,"is_in_doaj":true,"is_core":true,"listed_in":["anvur-scientific","cwts-core","doaj","dongbi-b","doyens","jufo-2","ki-jl-2","medline","norway-2","poland-70","russia-white-list-1"],"host_organization":"https://openalex.org/P4310315543","host_organization_name":"SPIE","host_organization_lineage":["https://openalex.org/P4310315543"],"host_organization_lineage_names":["SPIE"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Biomedical Optics","raw_type":"journal-article"},"volume":null,"type":"article","indexed_in":["crossref","doaj","pubmed"],"open_access":{"is_oa":true,"oa_status":"bronze","oa_url":"https://www.spiedigitallibrary.org/journals/journal-of-biomedical-optics/volume-19/issue-8/085001/Investigating-femtosecond-laser-induced-two-photon-photoacoustic-generation/10.1117/1.JBO.19.8.085001.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5037093199","display_name":"Ben E. Urban","orcid":"https://orcid.org/0000-0003-0809-3638","observed_orcids":["https://orcid.org/0000-0003-0809-3638"]},"institutions":[{"id":"https://openalex.org/I111979921","display_name":"Northwestern University","ror":"https://ror.org/000e0be47","country_code":"US","type":"education","lineage":["https://openalex.org/I111979921"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Ben E. Urban","raw_affiliation_strings":["Northwestern Univ","Northwestern University, Department of Biomedical Engineering, Evanston, Illinois 60208, United States"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Northwestern Univ","institution_ids":["https://openalex.org/I111979921"]},{"raw_affiliation_string":"Northwestern University, Department of Biomedical Engineering, Evanston, Illinois 60208, United States","institution_ids":["https://openalex.org/I111979921"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5015297358","display_name":"Ji Yi","orcid":"https://orcid.org/0000-0001-6583-7192","observed_orcids":["https://orcid.org/0000-0001-6583-7192"]},"institutions":[{"id":"https://openalex.org/I111979921","display_name":"Northwestern University","ror":"https://ror.org/000e0be47","country_code":"US","type":"education","lineage":["https://openalex.org/I111979921"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Ji Yi","raw_affiliation_strings":["Northwestern Univ","Northwestern University, Department of Biomedical Engineering, Evanston, Illinois 60208, United States"],"raw_orcid":"https://orcid.org/0000-0001-6583-7192","affiliations":[{"raw_affiliation_string":"Northwestern Univ","institution_ids":["https://openalex.org/I111979921"]},{"raw_affiliation_string":"Northwestern University, Department of Biomedical Engineering, Evanston, Illinois 60208, United States","institution_ids":["https://openalex.org/I111979921"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5006531736","display_name":"Vladislav V. Yakovlev","orcid":"https://orcid.org/0000-0002-4557-1013","observed_orcids":["https://orcid.org/0000-0002-4557-1013"]},"institutions":[{"id":"https://openalex.org/I91045830","display_name":"Texas A&M University","ror":"https://ror.org/01f5ytq51","country_code":"US","type":"education","lineage":["https://openalex.org/I91045830"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Vladislav Yakovlev","raw_affiliation_strings":["Texas A&M Univ","Texas A&M University, Department of Biomedical Engineering, College Station, Texas 77843, United States"],"raw_orcid":"https://orcid.org/0000-0002-4557-1013","affiliations":[{"raw_affiliation_string":"Texas A&M Univ","institution_ids":["https://openalex.org/I91045830"]},{"raw_affiliation_string":"Texas A&M University, Department of Biomedical Engineering, College Station, Texas 77843, United States","institution_ids":["https://openalex.org/I91045830"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5079750663","display_name":"Hao F. Zhang","orcid":"https://orcid.org/0000-0001-5089-1196","observed_orcids":["https://orcid.org/0000-0001-5089-1196"]},"institutions":[{"id":"https://openalex.org/I111979921","display_name":"Northwestern University","ror":"https://ror.org/000e0be47","country_code":"US","type":"education","lineage":["https://openalex.org/I111979921"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Hao F. Zhang","raw_affiliation_strings":["Northwestern Univ","Northwestern University, Department of Biomedical Engineering, Evanston, Illinois 60208, United States"],"raw_orcid":"https://orcid.org/0000-0001-5089-1196","affiliations":[{"raw_affiliation_string":"Northwestern Univ","institution_ids":["https://openalex.org/I111979921"]},{"raw_affiliation_string":"Northwestern University, Department of Biomedical Engineering, Evanston, Illinois 60208, United States","institution_ids":["https://openalex.org/I111979921"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":1675,"currency":"USD","value_usd":1675},"apc_paid":null,"fwci":0.8283,"has_fulltext":true,"cited_by_count":11,"citation_normalized_percentile":{"value":0.72242969,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":97},"biblio":{"volume":"19","issue":"08","first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12015","display_name":"Photoacoustic and Ultrasonic Imaging","score":0.9922000169754028,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12015","display_name":"Photoacoustic and Ultrasonic Imaging","score":0.9922000169754028,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11324","display_name":"Spectroscopy Techniques in Biomedical and Chemical Research","score":0.0013000000035390258,"subfield":{"id":"https://openalex.org/subfields/1304","display_name":"Biophysics"},"field":{"id":"https://openalex.org/fields/13","display_name":"Biochemistry, Genetics and Molecular Biology"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},{"id":"https://openalex.org/T11856","display_name":"Thermography and Photoacoustic Techniques","score":0.0010000000474974513,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/femtosecond-laser","display_name":"femtosecond laser","score":0.8029999732971191},{"id":"https://openalex.org/keywords/two-photon-absorption","display_name":"two-photon absorption","score":0.9390000104904175},{"id":"https://openalex.org/keywords/photoluminescence","display_name":"photoluminescence","score":0.9810000061988831},{"id":"https://openalex.org/keywords/light-scattering","display_name":"light scattering","score":0.972000002861023},{"id":"https://openalex.org/keywords/ultrasonic-attenuation","display_name":"ultrasonic attenuation","score":0.9470000267028809},{"id":"https://openalex.org/keywords/nonlinear-optical-imaging","display_name":"nonlinear optical imaging","score":0.4099999964237213}],"concepts":[{"id":"https://openalex.org/C85080765","wikidata":"https://www.wikidata.org/wiki/Q614893","display_name":"Photoluminescence","level":2,"score":0.8967392444610596},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.7110517024993896},{"id":"https://openalex.org/C163740662","wikidata":"https://www.wikidata.org/wiki/Q7187702","display_name":"Photoacoustic effect","level":3,"score":0.7016563415527344},{"id":"https://openalex.org/C167735695","wikidata":"https://www.wikidata.org/wiki/Q1777507","display_name":"Femtosecond","level":3,"score":0.5807017683982849},{"id":"https://openalex.org/C520434653","wikidata":"https://www.wikidata.org/wiki/Q38867","display_name":"Laser","level":2,"score":0.5794607996940613},{"id":"https://openalex.org/C159774933","wikidata":"https://www.wikidata.org/wiki/Q902086","display_name":"Attenuation coefficient","level":2,"score":0.5658083558082581},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.5599746704101562},{"id":"https://openalex.org/C184652730","wikidata":"https://www.wikidata.org/wiki/Q2357982","display_name":"Attenuation","level":2,"score":0.550171971321106},{"id":"https://openalex.org/C125287762","wikidata":"https://www.wikidata.org/wiki/Q1758948","display_name":"Absorption (acoustics)","level":2,"score":0.5342764854431152},{"id":"https://openalex.org/C191486275","wikidata":"https://www.wikidata.org/wiki/Q210028","display_name":"Scattering","level":2,"score":0.5231893658638},{"id":"https://openalex.org/C2777286522","wikidata":"https://www.wikidata.org/wiki/Q900415","display_name":"Photoacoustic spectroscopy","level":3,"score":0.5057199001312256},{"id":"https://openalex.org/C22078206","wikidata":"https://www.wikidata.org/wiki/Q1418023","display_name":"Fluence","level":3,"score":0.49854278564453125},{"id":"https://openalex.org/C54932901","wikidata":"https://www.wikidata.org/wiki/Q7187705","display_name":"Photoacoustic imaging in biomedicine","level":2,"score":0.4967105984687805},{"id":"https://openalex.org/C159317903","wikidata":"https://www.wikidata.org/wiki/Q3198","display_name":"Photon","level":2,"score":0.4958365857601166},{"id":"https://openalex.org/C31771446","wikidata":"https://www.wikidata.org/wiki/Q7187700","display_name":"Photoacoustic Doppler effect","level":3,"score":0.47798842191696167},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.4457194209098816},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.16738712787628174}],"mesh":[{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007089","descriptor_name":"Image Enhancement","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D007089","descriptor_name":"Image Enhancement","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D007089","descriptor_name":"Image Enhancement","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D007089","descriptor_name":"Image Enhancement","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D007089","descriptor_name":"Image Enhancement","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D007834","descriptor_name":"Lasers","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D007834","descriptor_name":"Lasers","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D007834","descriptor_name":"Lasers","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D007834","descriptor_name":"Lasers","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D007834","descriptor_name":"Lasers","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D008163","descriptor_name":"Luminescent Measurements","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D008163","descriptor_name":"Luminescent Measurements","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D008163","descriptor_name":"Luminescent Measurements","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D008163","descriptor_name":"Luminescent Measurements","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D008163","descriptor_name":"Luminescent Measurements","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012680","descriptor_name":"Sensitivity and Specificity","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D015203","descriptor_name":"Reproducibility of Results","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019047","descriptor_name":"Phantoms, Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019047","descriptor_name":"Phantoms, Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019047","descriptor_name":"Phantoms, Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019047","descriptor_name":"Phantoms, Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019047","descriptor_name":"Phantoms, Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019544","descriptor_name":"Equipment Failure Analysis","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D021621","descriptor_name":"Imaging, Three-Dimensional","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D021621","descriptor_name":"Imaging, Three-Dimensional","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D021621","descriptor_name":"Imaging, Three-Dimensional","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D021621","descriptor_name":"Imaging, Three-Dimensional","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D021621","descriptor_name":"Imaging, Three-Dimensional","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D036641","descriptor_name":"Microscopy, Fluorescence, Multiphoton","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D036641","descriptor_name":"Microscopy, Fluorescence, Multiphoton","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D036641","descriptor_name":"Microscopy, Fluorescence, Multiphoton","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D036641","descriptor_name":"Microscopy, Fluorescence, Multiphoton","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D036641","descriptor_name":"Microscopy, Fluorescence, Multiphoton","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D054459","descriptor_name":"Elasticity Imaging Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D054459","descriptor_name":"Elasticity Imaging Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D054459","descriptor_name":"Elasticity Imaging Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D054459","descriptor_name":"Elasticity Imaging Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D054459","descriptor_name":"Elasticity Imaging Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D061088","descriptor_name":"Photoacoustic Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D061088","descriptor_name":"Photoacoustic Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D061088","descriptor_name":"Photoacoustic Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D061088","descriptor_name":"Photoacoustic Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D061088","descriptor_name":"Photoacoustic Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false}],"locations_count":3,"locations":[{"id":"doi:10.1117/1.jbo.19.8.085001","doi":"https://doi.org/10.1117/1.jbo.19.8.085001","is_oa":true,"landing_page_url":"https://doi.org/10.1117/1.jbo.19.8.085001","pdf_url":"https://www.spiedigitallibrary.org/journals/journal-of-biomedical-optics/volume-19/issue-8/085001/Investigating-femtosecond-laser-induced-two-photon-photoacoustic-generation/10.1117/1.JBO.19.8.085001.pdf","source":{"id":"https://openalex.org/S117354312","display_name":"Journal of Biomedical Optics","issn_l":"1083-3668","issn":["1083-3668","1560-2281"],"is_oa":false,"is_in_doaj":true,"is_core":true,"listed_in":["anvur-scientific","cwts-core","doaj","dongbi-b","doyens","jufo-2","ki-jl-2","medline","norway-2","poland-70","russia-white-list-1"],"host_organization":"https://openalex.org/P4310315543","host_organization_name":"SPIE","host_organization_lineage":["https://openalex.org/P4310315543"],"host_organization_lineage_names":["SPIE"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Biomedical Optics","raw_type":"journal-article"},{"id":"pmid:25084119","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/25084119","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of biomedical optics","raw_type":"Comparative Study"},{"id":"pmh:oai:pubmedcentral.nih.gov:4118047","doi":null,"is_oa":true,"landing_page_url":"https://www.ncbi.nlm.nih.gov/pmc/articles/4118047","pdf_url":null,"source":{"id":"https://openalex.org/S2764455111","display_name":"PubMed Central","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"J Biomed Opt","raw_type":"Text"}],"best_oa_location":{"id":"doi:10.1117/1.jbo.19.8.085001","doi":"https://doi.org/10.1117/1.jbo.19.8.085001","is_oa":true,"landing_page_url":"https://doi.org/10.1117/1.jbo.19.8.085001","pdf_url":"https://www.spiedigitallibrary.org/journals/journal-of-biomedical-optics/volume-19/issue-8/085001/Investigating-femtosecond-laser-induced-two-photon-photoacoustic-generation/10.1117/1.JBO.19.8.085001.pdf","source":{"id":"https://openalex.org/S117354312","display_name":"Journal of Biomedical Optics","issn_l":"1083-3668","issn":["1083-3668","1560-2281"],"is_oa":false,"is_in_doaj":true,"is_core":true,"listed_in":["anvur-scientific","cwts-core","doaj","dongbi-b","doyens","jufo-2","ki-jl-2","medline","norway-2","poland-70","russia-white-list-1"],"host_organization":"https://openalex.org/P4310315543","host_organization_name":"SPIE","host_organization_lineage":["https://openalex.org/P4310315543"],"host_organization_lineage_names":["SPIE"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Biomedical Optics","raw_type":"journal-article"},"sustainable_development_goals":[],"sustainable_development_goals_aurora":[],"study_designs":[],"awards":[{"id":"https://openalex.org/G1268790672","display_name":null,"funder_award_id":"CBET-1055379","funder_id":"https://openalex.org/F4320332161","funder_display_name":"National Institutes of Health"},{"id":"https://openalex.org/G1972581785","display_name":null,"funder_award_id":"CBET-1055379","funder_id":"https://openalex.org/F4320337390","funder_display_name":"Division of Chemical, Bioengineering, Environmental, and Transport Systems"},{"id":"https://openalex.org/G2674981899","display_name":null,"funder_award_id":"CBET-1066776","funder_id":"https://openalex.org/F4320337390","funder_display_name":"Division of Chemical, Bioengineering, Environmental, and Transport Systems"},{"id":"https://openalex.org/G4222852505","display_name":"Multimodal Retinal Functional Imaging for Diabetic Retinopathy","funder_award_id":"R01EY019951","funder_id":"https://openalex.org/F4320337350","funder_display_name":"National Eye Institute"},{"id":"https://openalex.org/G4271521138","display_name":"Collaborative Research in Biophotonics: Towards high-resolution, label-free molecular imaging in deep tissue via stimulated Raman excitation and ultrasound detection","funder_award_id":"1066776","funder_id":"https://openalex.org/F4320306076","funder_display_name":"National Science Foundation"},{"id":"https://openalex.org/G4439475616","display_name":null,"funder_award_id":"R24 EY022883","funder_id":"https://openalex.org/F4320337350","funder_display_name":"National Eye Institute"},{"id":"https://openalex.org/G4902315419","display_name":"CAREER: Functional imaging to prevent blindness","funder_award_id":"1055379","funder_id":"https://openalex.org/F4320306076","funder_display_name":"National Science Foundation"},{"id":"https://openalex.org/G718077142","display_name":"Collaborative Research in Biophotonics: Towards high-resolution, label-free molecular imaging in deep tissue via stimulated Raman excitation and ultrasound detection","funder_award_id":"1066562","funder_id":"https://openalex.org/F4320306076","funder_display_name":"National Science Foundation"},{"id":"https://openalex.org/G7873484468","display_name":null,"funder_award_id":"1R24EY022883","funder_id":"https://openalex.org/F4320337350","funder_display_name":"National Eye Institute"},{"id":"https://openalex.org/G9000115067","display_name":null,"funder_award_id":"1R24EY022883","funder_id":"https://openalex.org/F4320332161","funder_display_name":"National Institutes of Health"},{"id":"https://openalex.org/G949422507","display_name":null,"funder_award_id":"1055379","funder_id":"https://openalex.org/F4320337390","funder_display_name":"Division of Chemical, Bioengineering, Environmental, and Transport Systems"}],"funders":[{"id":"https://openalex.org/F4320306076","display_name":"National Science Foundation","ror":"https://ror.org/021nxhr62"},{"id":"https://openalex.org/F4320332161","display_name":"National Institutes of Health","ror":"https://ror.org/01cwqze88"},{"id":"https://openalex.org/F4320337350","display_name":"National Eye Institute","ror":"https://ror.org/03wkg3b53"},{"id":"https://openalex.org/F4320337390","display_name":"Division of Chemical, Bioengineering, Environmental, and Transport Systems","ror":"https://ror.org/0471zv972"}],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2077934603.pdf","grobid_xml":"https://content.openalex.org/works/W2077934603.grobid-xml"},"referenced_works_count":26,"referenced_works":["https://openalex.org/W1503379212","https://openalex.org/W1966102873","https://openalex.org/W1980285018","https://openalex.org/W1993909708","https://openalex.org/W2008218710","https://openalex.org/W2015622350","https://openalex.org/W2030964111","https://openalex.org/W2033705563","https://openalex.org/W2033725915","https://openalex.org/W2033833146","https://openalex.org/W2036176151","https://openalex.org/W2045582770","https://openalex.org/W2062323346","https://openalex.org/W2063006071","https://openalex.org/W2072018601","https://openalex.org/W2083412569","https://openalex.org/W2099132116","https://openalex.org/W2113504999","https://openalex.org/W2118997868","https://openalex.org/W2126375075","https://openalex.org/W2130866683","https://openalex.org/W2136537123","https://openalex.org/W2148309086","https://openalex.org/W2149366457","https://openalex.org/W2168157948","https://openalex.org/W4255137887"],"related_works":["https://openalex.org/W4388497782","https://openalex.org/W2012822947","https://openalex.org/W390006624","https://openalex.org/W1641242311","https://openalex.org/W2034134512","https://openalex.org/W2059644683","https://openalex.org/W2372669038","https://openalex.org/W4387716966","https://openalex.org/W1769707307","https://openalex.org/W2013892756"],"abstract_inverted_index":{"We":[0,30],"investigated":[1,32],"two-photon":[2,42,86],"absorption-based":[3],"photoacoustic":[4,26,43,50,87],"generation":[5,40],"and":[6,27,44,47],"compared":[7],"it":[8],"with":[9],"corresponding":[10],"photoluminescence":[11,28,45,56],"emission.":[12],"Experimental":[13],"results":[14],"revealed":[15],"expected":[16],"quadratic":[17],"dependences":[18],"on":[19,38],"the":[20,33,39,59,75,79],"incident":[21],"optical":[22,36,60,76],"fluence":[23],"in":[24,78],"both":[25],"processes.":[29],"also":[31],"influence":[34],"of":[35,41],"scattering":[37,61,80],"signals":[46,51,57],"found":[48],"that":[49,74],"attenuated":[52],"more":[53],"slowly":[54],"than":[55,73],"when":[58],"coefficient":[62],"was":[63,66],"increased,":[64],"which":[65],"attributed":[67],"to":[68],"a":[69],"weaker":[70],"ultrasonic":[71],"attenuation":[72,77],"medium.":[81],"Finally,":[82],"we":[83],"showed":[84],"three-dimensional":[85],"imaging.":[88]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2018,"cited_by_count":2},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":3},{"year":2015,"cited_by_count":1}],"updated_date":"2026-10-15T10:00:46.086208","created_date":"2025-10-10T00:00:00"}
