{"id":"https://openalex.org/W2076972241","doi":"https://doi.org/10.1541/ieejpes.125.373","title":"A Development of the Decision Support System for the Optimum Cogeneration Planning Under the Constraints of the Economic Efficiency and Partial Load Properties for the Commercial Building","display_name":"A Development of the Decision Support System for the Optimum Cogeneration Planning Under the Constraints of the Economic Efficiency and Partial Load Properties for the Commercial Building","publication_year":2005,"publication_date":"2005-01-01","ids":{"openalex":"https://openalex.org/W2076972241","doi":"https://doi.org/10.1541/ieejpes.125.373","mag":"2076972241"},"language":"en","primary_location":{"id":"doi:10.1541/ieejpes.125.373","doi":"https://doi.org/10.1541/ieejpes.125.373","is_oa":true,"landing_page_url":"https://doi.org/10.1541/ieejpes.125.373","pdf_url":"https://www.jstage.jst.go.jp/article/ieejpes/125/4/125_4_373/_pdf","source":{"id":"https://openalex.org/S53799065","display_name":"IEEJ Transactions on Power and Energy","issn_l":"0385-4213","issn":["0385-4213","1348-8147"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["poland-70","russia-white-list-3"],"host_organization":"https://openalex.org/P4320800591","host_organization_name":"Institute of Electrical Engineers of Japan","host_organization_lineage":["https://openalex.org/P4320800591"],"host_organization_lineage_names":["Institute of Electrical Engineers of Japan"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEJ Transactions on Power and Energy","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"bronze","oa_url":"https://www.jstage.jst.go.jp/article/ieejpes/125/4/125_4_373/_pdf","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5073899650","display_name":"Takeshi Ishida","orcid":"https://orcid.org/0000-0002-3162-0857","observed_orcids":["https://orcid.org/0000-0002-3162-0857"]},"institutions":[{"id":"https://openalex.org/I4405255371","display_name":"Systems Research & Development Institute of Japan","ror":"https://ror.org/02y8cd205","country_code":"JP","type":"facility","lineage":["https://openalex.org/I4405255371"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Takeshi Ishida","raw_affiliation_strings":["Systems Research & Development Institute of Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Systems Research & Development Institute of Japan","institution_ids":["https://openalex.org/I4405255371"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101479546","display_name":"Shunsuke Mori","orcid":"https://orcid.org/0000-0002-0852-0049","observed_orcids":["https://orcid.org/0000-0002-0852-0049"]},"institutions":[{"id":"https://openalex.org/I161296585","display_name":"Tokyo University of Science","ror":"https://ror.org/05sj3n476","country_code":"JP","type":"education","lineage":["https://openalex.org/I161296585"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Shunsuke Mori","raw_affiliation_strings":["Tokyo University of Science"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Tokyo University of Science","institution_ids":["https://openalex.org/I161296585"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5045830268","display_name":"Kiyoshi Douwaki","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I161296585","display_name":"Tokyo University of Science","ror":"https://ror.org/05sj3n476","country_code":"JP","type":"education","lineage":["https://openalex.org/I161296585"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Kiyoshi Douwaki","raw_affiliation_strings":["Tokyo University of Science"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Tokyo University of Science","institution_ids":["https://openalex.org/I161296585"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.9221,"has_fulltext":true,"cited_by_count":6,"citation_normalized_percentile":{"value":0.75175805,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":93},"biblio":{"volume":"125","issue":"4","first_page":"373","last_page":"380"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11185","display_name":"Integrated Energy Systems Optimization","score":0.9326000213623047,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11185","display_name":"Integrated Energy Systems Optimization","score":0.9326000213623047,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10568","display_name":"Thermodynamic and Exergetic Analyses of Power and Cooling Systems","score":0.030799999833106995,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.020400000736117363,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/combined-heat-and-power","display_name":"combined heat and power","score":0.8019999861717224},{"id":"https://openalex.org/keywords/decision-support-system","display_name":"decision support system","score":0.8460000157356262},{"id":"https://openalex.org/keywords/part-load-operation","display_name":"off-design operation","score":0.7279999852180481},{"id":"https://openalex.org/keywords/commercial-buildings","display_name":"commercial buildings","score":0.6470000147819519},{"id":"https://openalex.org/keywords/mixed-integer-nonlinear-programming","display_name":"mixed-integer nonlinear programming","score":0.6940000057220459},{"id":"https://openalex.org/keywords/investment-recovery-period","display_name":"investment recovery period","score":0.8059999942779541},{"id":"https://openalex.org/keywords/economic-efficiency","display_name":"economic efficiency","score":0.6959999799728394},{"id":"https://openalex.org/keywords/energy-conservation","display_name":"energy conservation","score":0.9279999732971191},{"id":"https://openalex.org/keywords/hotels","display_name":"hotels","score":0.6000000238418579},{"id":"https://openalex.org/keywords/load-factor","display_name":"load factor","score":0.5600000023841858}],"concepts":[{"id":"https://openalex.org/C2776756539","wikidata":"https://www.wikidata.org/wiki/Q221620","display_name":"Cogeneration","level":4,"score":0.7136937975883484},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.5410728454589844},{"id":"https://openalex.org/C115527620","wikidata":"https://www.wikidata.org/wiki/Q769909","display_name":"Nonlinear programming","level":3,"score":0.5156687498092651},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.49147188663482666},{"id":"https://openalex.org/C27548731","wikidata":"https://www.wikidata.org/wiki/Q88272","display_name":"Investment (military)","level":3,"score":0.4161013662815094},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.4151741564273834},{"id":"https://openalex.org/C42475967","wikidata":"https://www.wikidata.org/wiki/Q194292","display_name":"Operations research","level":1,"score":0.37313026189804077},{"id":"https://openalex.org/C158622935","wikidata":"https://www.wikidata.org/wiki/Q660848","display_name":"Nonlinear system","level":2,"score":0.35977989435195923},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3154653310775757},{"id":"https://openalex.org/C423512","wikidata":"https://www.wikidata.org/wiki/Q383973","display_name":"Electricity generation","level":3,"score":0.28193551301956177},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.19446265697479248},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.129332035779953},{"id":"https://openalex.org/C17744445","wikidata":"https://www.wikidata.org/wiki/Q36442","display_name":"Political science","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C199539241","wikidata":"https://www.wikidata.org/wiki/Q7748","display_name":"Law","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C94625758","wikidata":"https://www.wikidata.org/wiki/Q7163","display_name":"Politics","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1541/ieejpes.125.373","doi":"https://doi.org/10.1541/ieejpes.125.373","is_oa":true,"landing_page_url":"https://doi.org/10.1541/ieejpes.125.373","pdf_url":"https://www.jstage.jst.go.jp/article/ieejpes/125/4/125_4_373/_pdf","source":{"id":"https://openalex.org/S53799065","display_name":"IEEJ Transactions on Power and Energy","issn_l":"0385-4213","issn":["0385-4213","1348-8147"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["poland-70","russia-white-list-3"],"host_organization":"https://openalex.org/P4320800591","host_organization_name":"Institute of Electrical Engineers of Japan","host_organization_lineage":["https://openalex.org/P4320800591"],"host_organization_lineage_names":["Institute of Electrical Engineers of Japan"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEJ Transactions on Power and Energy","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.1541/ieejpes.125.373","doi":"https://doi.org/10.1541/ieejpes.125.373","is_oa":true,"landing_page_url":"https://doi.org/10.1541/ieejpes.125.373","pdf_url":"https://www.jstage.jst.go.jp/article/ieejpes/125/4/125_4_373/_pdf","source":{"id":"https://openalex.org/S53799065","display_name":"IEEJ Transactions on Power and Energy","issn_l":"0385-4213","issn":["0385-4213","1348-8147"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["poland-70","russia-white-list-3"],"host_organization":"https://openalex.org/P4320800591","host_organization_name":"Institute of Electrical Engineers of Japan","host_organization_lineage":["https://openalex.org/P4320800591"],"host_organization_lineage_names":["Institute of Electrical Engineers of Japan"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEJ Transactions on Power and Energy","raw_type":"journal-article"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.878000020980835,"id":"https://metadata.un.org/sdg/7"},{"display_name":"Industry, innovation and infrastructure","score":0.7207000255584717,"id":"https://metadata.un.org/sdg/9"},{"display_name":"Climate action","score":0.5351999998092651,"id":"https://metadata.un.org/sdg/13"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2076972241.pdf","grobid_xml":"https://content.openalex.org/works/W2076972241.grobid-xml"},"referenced_works_count":1,"referenced_works":["https://openalex.org/W2516764956"],"related_works":["https://openalex.org/W1974286772","https://openalex.org/W2027333023","https://openalex.org/W1991419708","https://openalex.org/W2084274791","https://openalex.org/W2212312811","https://openalex.org/W2064396990","https://openalex.org/W2136968742","https://openalex.org/W2084133837","https://openalex.org/W2734167708","https://openalex.org/W2028339156"],"abstract_inverted_index":{"It":[0],"is":[1,8],"said":[2],"that":[3,166],"the":[4,19,23,36,41,57,61,64,78,88,106,109,113,119,135,141,148,157,167,182],"cogeneration":[5],"system":[6,122,133,152],"(CGS)":[7],"an":[9,129],"effective":[10,178],"countermeasure":[11],"for":[12,147],"energy":[13,25,110,131],"saving":[14,111,132],"and":[15,26,40,46,63,108],"CO2":[16],"reduction":[17],"in":[18,74,84],"commercial":[20,149],"building.":[21,150,161],"However,":[22],"economic,":[24],"environmental":[27],"efficiency":[28,139],"of":[29,44,67,82,102,112,137,145,159],"CGS":[30,68,83,114,146,169],"varies":[31],"so":[32],"much":[33],"depending":[34],"on":[35,60],"annual":[37],"load":[38,80,94],"factor":[39],"demand":[42],"patterns":[43],"heat":[45],"electric":[47],"power.In":[48],"this":[49],"research,":[50],"we":[51],"develop":[52,128],"a":[53,124],"model":[54,175],"to":[55,76,127,156,181],"evaluate":[56],"optimum":[58,168],"decision":[59],"capacity":[62,170],"operating":[65],"pattern":[66],"by":[69,173],"nonlinear":[70],"mixing":[71],"integer":[72],"programming":[73],"order":[75],"formulate":[77],"partial":[79,93],"properties":[81,95],"practical":[85],"operation,":[86],"since":[87],"existing":[89,183],"optimization":[90,189],"models":[91],"without":[92,188],"could":[96],"have":[97],"generated":[98,172],"too":[99],"optimistic":[100],"evaluation":[101],"CGS.The":[103],"compatibility":[104],"between":[105],"economy":[107],"implementation":[115],"planning":[116,171],"has":[117,153],"been":[118,154],"problem.":[120],"Our":[121,151],"proposes":[123],"new":[125],"measure":[126],"optimal":[130],"under":[134],"constraint":[136],"economic":[138],"as":[140],"investment":[142],"recovery":[143],"years":[144],"applied":[155],"case":[158],"hotel":[160],"The":[162],"results":[163],"show":[164],"us":[165],"our":[174],"provides":[176],"more":[177],"solution":[179],"compared":[180],"simulation":[184],"tools":[185],"used":[186],"generally":[187],"capability.":[190]},"counts_by_year":[{"year":2020,"cited_by_count":1}],"updated_date":"2026-09-22T17:25:34.749102","created_date":"2016-06-24T00:00:00"}
