{"id":"https://openalex.org/W2072988481","doi":"https://doi.org/10.1061/(asce)1076-0342(2004)10:3(98)","title":"Data Centers Revisited: Assessment of the Energy Impact of Retrofits and Technology Trends in a High-Density Computing Facility","display_name":"Data Centers Revisited: Assessment of the Energy Impact of Retrofits and Technology Trends in a High-Density Computing Facility","alternate_titles":[],"publication_year":2004,"publication_date":"2004-08-17","ids":{"openalex":"https://openalex.org/W2072988481","doi":"https://doi.org/10.1061/(asce)1076-0342(2004)10:3(98)","mag":"2072988481"},"language":"en","primary_location":{"id":"doi:10.1061/(asce)1076-0342(2004)10:3(98)","doi":"https://doi.org/10.1061/(asce)1076-0342(2004)10:3(98)","is_oa":false,"landing_page_url":"https://doi.org/10.1061/(asce)1076-0342(2004)10:3(98)","pdf_url":null,"source":{"id":"https://openalex.org/S54853311","display_name":"Journal of Infrastructure Systems","issn_l":"1076-0342","issn":["1076-0342","1943-555X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-1","norway-1","poland-70","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310315747","host_organization_name":"American Society of Civil Engineers","host_organization_lineage":["https://openalex.org/P4310315747"],"host_organization_lineage_names":["American Society of Civil Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Infrastructure Systems","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2072988481"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5028684507","display_name":"Michele Blazek C","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I1283103587","display_name":"AT&T (United States)","ror":"https://ror.org/02bbd5539","country_code":"US","type":"company","lineage":["https://openalex.org/I1283103587"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Michele Blazek","raw_affiliation_strings":["Director, Technology and Environment, AT&T, 4430 Rosewood Dr., Ste. 3188, Pleasanton, CA 94930"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Director, Technology and Environment, AT&T, 4430 Rosewood Dr., Ste. 3188, Pleasanton, CA 94930","institution_ids":["https://openalex.org/I1283103587"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5017813787","display_name":"Huimin Chong","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Huimin Chong","raw_affiliation_strings":["Business Development Executive, Singapore Computer Systems, Ltd., Blk 10G, Braddell Hill #04-28, Singapore, 579726"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Business Development Executive, Singapore Computer Systems, Ltd., Blk 10G, Braddell Hill #04-28, Singapore, 579726","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5018814340","display_name":"Woonsien Loh","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I2799859190","display_name":"Infocomm Development Authority of Singapore","ror":"https://ror.org/04pyne868","country_code":"SG","type":"government","lineage":["https://openalex.org/I2799859190","https://openalex.org/I4210106279","https://openalex.org/I4387152468"]}],"countries":["SG"],"is_corresponding":false,"raw_author_name":"Woonsien Loh","raw_affiliation_strings":["Assistant Manager, Business Development, InfoComm Development Authority of Singapore, 7 Siglap Rd., #10-55, Singapore 448909"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Assistant Manager, Business Development, InfoComm Development Authority of Singapore, 7 Siglap Rd., #10-55, Singapore 448909","institution_ids":["https://openalex.org/I2799859190"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5037343559","display_name":"Jonathan Koomey","orcid":"https://orcid.org/0000-0002-2983-344X","observed_orcids":["https://orcid.org/0000-0002-2983-344X"]},"institutions":[{"id":"https://openalex.org/I97018004","display_name":"Stanford University","ror":"https://ror.org/00f54p054","country_code":"US","type":"education","lineage":["https://openalex.org/I97018004"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Jonathan G. Koomey","raw_affiliation_strings":["MAP/Ming Visiting Professor of Energy and Environment, Dept. of Civil and Environmental Engineering, Terman Engineering Center, Room 240, Stanford Univ., Stanford, CA 94305-4020"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"MAP/Ming Visiting Professor of Energy and Environment, Dept. of Civil and Environmental Engineering, Terman Engineering Center, Room 240, Stanford Univ., Stanford, CA 94305-4020","institution_ids":["https://openalex.org/I97018004"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.4641,"has_fulltext":false,"cited_by_count":22,"citation_normalized_percentile":{"value":0.71693469,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":97},"biblio":{"volume":"10","issue":"3","first_page":"98","last_page":"104"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T14098","display_name":"Energy Efficiency in Computing","score":0.5547000169754028,"subfield":{"id":"https://openalex.org/subfields/1708","display_name":"Hardware and Architecture"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T14098","display_name":"Energy Efficiency in Computing","score":0.5547000169754028,"subfield":{"id":"https://openalex.org/subfields/1708","display_name":"Hardware and Architecture"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12238","display_name":"Green IT and Sustainability","score":0.22519999742507935,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10101","display_name":"Cloud Computing and Resource Management","score":0.20000000298023224,"subfield":{"id":"https://openalex.org/subfields/1710","display_name":"Information Systems"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/data-centers","display_name":"data centers","score":0.781000018119812},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"energy consumption","score":0.7549999952316284},{"id":"https://openalex.org/keywords/power-density","display_name":"power density","score":0.8320000171661377},{"id":"https://openalex.org/keywords/computer-room-air-conditioning","display_name":"computer room air conditioning","score":0.7129999995231628},{"id":"https://openalex.org/keywords/power-distribution-unit","display_name":"power distribution unit","score":0.8519999980926514},{"id":"https://openalex.org/keywords/energy-efficiency","display_name":"energy efficiency","score":0.6779999732971191},{"id":"https://openalex.org/keywords/facility-control","display_name":"facility control","score":0.4740000069141388},{"id":"https://openalex.org/keywords/power-management-module","display_name":"power management module","score":0.718999981880188},{"id":"https://openalex.org/keywords/high-density-computing","display_name":"high-density computing","score":0.699999988079071},{"id":"https://openalex.org/keywords/energy-efficiency-metrics","display_name":"energy efficiency metrics","score":0.5770000219345093}],"concepts":[{"id":"https://openalex.org/C153740404","wikidata":"https://www.wikidata.org/wiki/Q671224","display_name":"Data center","level":2,"score":0.7022122740745544},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.526328980922699},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.49425482749938965},{"id":"https://openalex.org/C110875604","wikidata":"https://www.wikidata.org/wiki/Q75","display_name":"The Internet","level":2,"score":0.4751293957233429},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4534875750541687},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.4380970001220703},{"id":"https://openalex.org/C77088390","wikidata":"https://www.wikidata.org/wiki/Q8513","display_name":"Database","level":1,"score":0.38682880997657776},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.3576030135154724},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3519139885902405},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2551991641521454},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.21762284636497498},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.17955344915390015}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1061/(asce)1076-0342(2004)10:3(98)","doi":"https://doi.org/10.1061/(asce)1076-0342(2004)10:3(98)","is_oa":false,"landing_page_url":"https://doi.org/10.1061/(asce)1076-0342(2004)10:3(98)","pdf_url":null,"source":{"id":"https://openalex.org/S54853311","display_name":"Journal of Infrastructure Systems","issn_l":"1076-0342","issn":["1076-0342","1943-555X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-1","norway-1","poland-70","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310315747","host_organization_name":"American Society of Civil Engineers","host_organization_lineage":["https://openalex.org/P4310315747"],"host_organization_lineage_names":["American Society of Civil Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Infrastructure Systems","raw_type":"journal-article"},{"id":"pmh:oai:CiteSeerX.psu:10.1.1.362.4196","doi":null,"is_oa":false,"landing_page_url":"http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.362.4196","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"http://hightech.lbl.gov/documents/data_centers/blazekfinalpdf.pdf","raw_type":"text"}],"best_oa_location":null,"sustainable_development_goals":[{"score":1.0,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"},{"score":0.8485000133514404,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320338292","display_name":"Lawrence Berkeley National Laboratory","ror":"https://ror.org/02jbv0t02"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":9,"referenced_works":["https://openalex.org/W1510374856","https://openalex.org/W1548356485","https://openalex.org/W2086875833","https://openalex.org/W2101326083","https://openalex.org/W2144272241","https://openalex.org/W2165716982","https://openalex.org/W2351752585","https://openalex.org/W2567467922","https://openalex.org/W4285719527"],"related_works":["https://openalex.org/W2186705116","https://openalex.org/W2545089368","https://openalex.org/W7098062085","https://openalex.org/W2904950332","https://openalex.org/W2339817900","https://openalex.org/W2078227112","https://openalex.org/W4233097913","https://openalex.org/W1519682201","https://openalex.org/W2899352930"],"abstract_inverted_index":{"As":[0],"information":[1,34],"and":[2,15,35,55,70,86,101,131,152,209],"communications":[3,36],"technology":[4,37],"matures,":[5],"the":[6,9,18,33,53,62,67,117,128,133,138,143,156,159,173,223,230,234],"nature":[7],"of":[8,46,61,110,190,233],"infrastructure":[10,20],"that":[11,115],"supports":[12],"it":[13],"evolves":[14],"specializes.":[16],"While":[17],"telephone":[19],"had":[21,120],"been":[22],"built":[23],"as":[24,31,158],"a":[25,39],"network":[26,236],"with":[27,137],"central":[28],"offices":[29],"acting":[30],"hubs,":[32],"maintains":[38],"similar":[40],"structure,":[41],"but":[42],"instead,":[43],"has":[44],"hubs":[45],"specialized":[47],"Internet":[48,75],"data":[49,76,91,118,235],"centers":[50],"which":[51],"house":[52],"routers":[54],"servers.":[56],"This":[57],"paper":[58],"updates":[59],"one":[60],"first":[63],"studies":[64],"to":[65,94,168,202,217,221,225,228],"document":[66],"electricity":[68,81,134],"consumption":[69],"power":[71,103,147,191,194],"distribution":[72,192],"within":[73],"an":[74,177],"center.":[77],"For":[78],"this":[79,111,219],"study,":[80],"billing":[82],"data,":[83,85],"metering":[84],"facility":[87,211],"floor":[88],"space":[89],"allocation":[90],"were":[92],"used":[93],"calculate":[95],"computer":[96,99,139,145,181,197],"room,":[97,100],"total":[98,144],"building":[102],"densities":[104],"for":[105],"July":[106],"2002.":[107],"The":[108,165,184],"results":[109],"2002":[112],"study":[113],"indicate":[114],"although":[116],"center":[119],"expanded":[121],"its":[122],"operations":[123],"by":[124,141],"roughly":[125],"33%":[126],"from":[127,176],"previous":[129,160],"year":[130,161],"increased":[132],"demand":[135,175],"associated":[136],"equipment":[140],"55%,":[142],"room":[146,182,198],"density":[148],"(which":[149],"includes":[150],"cooling":[151],"auxiliary":[153],"equipment)":[154],"remained":[155],"same":[157],"at":[162],"355":[163],"W/m2.":[164],"facility\u2019s":[166],"efforts":[167],"improve":[169],"energy":[170,174,231],"efficiency":[171,232],"offset":[172],"increased,":[178],"electrically":[179],"active,":[180],"area.":[183],"energy-efficiency":[185],"measures":[186],"included":[187],"better":[188],"optimization":[189],"units,":[193,200],"management":[195],"modules,":[196],"air-conditioning":[199],"alterations":[201],"operating":[203],"conditions,":[204],"facilitywide":[205],"reductions":[206],"in":[207],"lighting,":[208],"improved":[210],"controls.":[212],"A":[213],"key":[214],"recommendation":[215],"is":[216],"expand":[218],"research":[220],"address":[222],"need":[224],"develop":[226],"metrics":[227],"capture":[229],"throughput.":[237]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2072988481","counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2022,"cited_by_count":2},{"year":2019,"cited_by_count":2},{"year":2015,"cited_by_count":3},{"year":2014,"cited_by_count":4},{"year":2013,"cited_by_count":1},{"year":2012,"cited_by_count":1}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-06-24T00:00:00"}
