{"id":"https://openalex.org/W2069033281","doi":"https://doi.org/10.1080/10407789808913982","title":"THE EFFECT OF LONGITUDINAL WALL CONDUCTION IN A THREE-FLUID CROSSFLOW HEAT EXCHANGER","display_name":"THE EFFECT OF LONGITUDINAL WALL CONDUCTION IN A THREE-FLUID CROSSFLOW HEAT EXCHANGER","publication_year":1998,"publication_date":"1998-08-01","ids":{"openalex":"https://openalex.org/W2069033281","doi":"https://doi.org/10.1080/10407789808913982","mag":"2069033281"},"language":"en","primary_location":{"id":"doi:10.1080/10407789808913982","doi":"https://doi.org/10.1080/10407789808913982","is_oa":false,"landing_page_url":"https://doi.org/10.1080/10407789808913982","pdf_url":null,"source":{"id":"https://openalex.org/S84964104","display_name":"Numerical Heat Transfer Part A Applications","issn_l":"1040-7782","issn":["1040-7782","1521-0634"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-d","jufo-1","ki-jl-1","norway-1","poland-100","russia-white-list-1"],"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["Taylor & Francis","Informa"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Numerical Heat Transfer, Part A: Applications","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100847084","display_name":"Ping Yuan","orcid":"https://orcid.org/0009-0001-7300-4198","observed_orcids":["https://orcid.org/0009-0001-7300-4198"]},"institutions":[{"id":"https://openalex.org/I4405258395","display_name":"LeeMing Institute of Technology","ror":"https://ror.org/00k2r9g11","country_code":"TW","type":"education","lineage":["https://openalex.org/I4405258395"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Ping Yuan","raw_affiliation_strings":["Department of Mechanical Engineering, Lee-Ming Institute of Technology, Taipei, Taiwan, Republic of China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Mechanical Engineering, Lee-Ming Institute of Technology, Taipei, Taiwan, Republic of China","institution_ids":["https://openalex.org/I4405258395"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5110055427","display_name":"Hong\u2010Sen Kou","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I65196183","display_name":"Tatung University","ror":"https://ror.org/030m18266","country_code":"TW","type":"education","lineage":["https://openalex.org/I65196183"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Hong-Sen Kou","raw_affiliation_strings":["Department of Mechanical Engineering, Tatung Institute of Technology, Taipei, Taiwan, Republic of China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Mechanical Engineering, Tatung Institute of Technology, Taipei, Taiwan, Republic of China","institution_ids":["https://openalex.org/I65196183"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":4.4424,"has_fulltext":false,"cited_by_count":18,"citation_normalized_percentile":{"value":0.93311037,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":88,"max":96},"biblio":{"volume":"34","issue":"2","first_page":"135","last_page":"150"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10998","display_name":"Heat Transfer and Optimization","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10998","display_name":"Heat Transfer and Optimization","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13116","display_name":"Heat Transfer and Numerical Methods","score":0.0012000000569969416,"subfield":{"id":"https://openalex.org/subfields/2206","display_name":"Computational Mechanics"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11945","display_name":"Heat Transfer Mechanisms","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/degradation-factors","display_name":"degradation factors","score":0.8289999961853027},{"id":"https://openalex.org/keywords/number-of-transfer-units","display_name":"number of transfer units","score":0.8460000157356262},{"id":"https://openalex.org/keywords/thermal-performance","display_name":"thermal performance","score":0.6349999904632568}],"concepts":[{"id":"https://openalex.org/C172100665","wikidata":"https://www.wikidata.org/wiki/Q7465774","display_name":"Thermal conduction","level":2,"score":0.7097499370574951},{"id":"https://openalex.org/C50517652","wikidata":"https://www.wikidata.org/wiki/Q179635","display_name":"Heat transfer","level":2,"score":0.6702961921691895},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.5941594839096069},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.592980146408081},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5385104417800903},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.5167292952537537},{"id":"https://openalex.org/C33134510","wikidata":"https://www.wikidata.org/wiki/Q5158348","display_name":"Concentric tube heat exchanger","level":4,"score":0.5054142475128174},{"id":"https://openalex.org/C2777777821","wikidata":"https://www.wikidata.org/wiki/Q25111513","display_name":"Heat transfer enhancement","level":4,"score":0.48308065533638},{"id":"https://openalex.org/C192866977","wikidata":"https://www.wikidata.org/wiki/Q3294462","display_name":"Dynamic scraped surface heat exchanger","level":5,"score":0.48030537366867065},{"id":"https://openalex.org/C32375409","wikidata":"https://www.wikidata.org/wiki/Q261231","display_name":"Plate heat exchanger","level":3,"score":0.47574493288993835},{"id":"https://openalex.org/C29700514","wikidata":"https://www.wikidata.org/wiki/Q634340","display_name":"Heat transfer coefficient","level":3,"score":0.44672146439552307},{"id":"https://openalex.org/C90278072","wikidata":"https://www.wikidata.org/wiki/Q216320","display_name":"Fluid dynamics","level":2,"score":0.4450685381889343},{"id":"https://openalex.org/C118227150","wikidata":"https://www.wikidata.org/wiki/Q6839192","display_name":"Micro heat exchanger","level":4,"score":0.4407496750354767},{"id":"https://openalex.org/C48632124","wikidata":"https://www.wikidata.org/wiki/Q617088","display_name":"Heat spreader","level":3,"score":0.4177986979484558},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.17816093564033508},{"id":"https://openalex.org/C167131557","wikidata":"https://www.wikidata.org/wiki/Q5186725","display_name":"Critical heat flux","level":4,"score":0.1521168351173401},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.08947369456291199}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1080/10407789808913982","doi":"https://doi.org/10.1080/10407789808913982","is_oa":false,"landing_page_url":"https://doi.org/10.1080/10407789808913982","pdf_url":null,"source":{"id":"https://openalex.org/S84964104","display_name":"Numerical Heat Transfer Part A Applications","issn_l":"1040-7782","issn":["1040-7782","1521-0634"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-d","jufo-1","ki-jl-1","norway-1","poland-100","russia-white-list-1"],"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["Taylor & Francis","Informa"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Numerical Heat Transfer, Part A: Applications","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W1044336152","https://openalex.org/W1675131008","https://openalex.org/W1973485733","https://openalex.org/W2003133426","https://openalex.org/W2008062190","https://openalex.org/W2028548436","https://openalex.org/W2056761911","https://openalex.org/W2080360449","https://openalex.org/W2166215969","https://openalex.org/W2946230328"],"related_works":["https://openalex.org/W2056004544","https://openalex.org/W2008062190","https://openalex.org/W2030327895","https://openalex.org/W3159549165","https://openalex.org/W2080360449","https://openalex.org/W3083700770","https://openalex.org/W2995155328","https://openalex.org/W2084765268","https://openalex.org/W1975959686","https://openalex.org/W802325317"],"abstract_inverted_index":{"Because":[0],"of":[1,4,40,60,65,72,81],"the":[2,9,21,26,35,41,69,79],"effect":[3],"longitudinal":[5,92],"wall":[6,93],"conduction":[7,94],"on":[8],"thermal":[10],"performance":[11],"in":[12,29],"a":[13],"direct":[14],"transfer-type,":[15],"single-pass,":[16],"three-fluid":[17,42],"crossflow":[18,43],"heat":[19,44,83,87],"exchanger,":[20],"exit":[22],"mean":[23],"temperatures":[24],"and":[25,55,68,91],"deterioration":[27,61],"factors":[28],"each":[30],"fluid":[31,48,53,56,73],"are":[32,75],"calculated":[33],"by":[34],"numerical":[36],"method.":[37],"Unit":[38],"construction":[39],"exchanger":[45],"is":[46,50],"that":[47],"2":[49],"sandwiched":[51],"between":[52],"I":[54],"3.":[57],"The":[58],"results":[59],"factor":[62],"versus":[63],"number":[64],"transfer":[66,88],"units":[67],"inlet":[70],"temperature":[71],"3":[74],"explored":[76],"to":[77],"demonstrate":[78],"influences":[80],"different":[82],"capacity":[84],"rate":[85],"ratios,":[86,90],"resistance":[89],"ratios":[95]},"counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":1}],"updated_date":"2026-10-30T12:39:25.321706","created_date":"2016-06-24T00:00:00"}
