{"id":"https://openalex.org/W2065687169","doi":"https://doi.org/10.1109/tpas.1979.319524","title":"Natural Contamination test of Insulators at Noto Testing Station Near Japan Sea","display_name":"Natural Contamination test of Insulators at Noto Testing Station Near Japan Sea","alternate_titles":[],"publication_year":1979,"publication_date":"1979-01-01","ids":{"openalex":"https://openalex.org/W2065687169","doi":"https://doi.org/10.1109/tpas.1979.319524","mag":"2065687169"},"language":"en","primary_location":{"id":"doi:10.1109/tpas.1979.319524","doi":"https://doi.org/10.1109/tpas.1979.319524","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tpas.1979.319524","pdf_url":null,"source":{"id":"https://openalex.org/S35391503","display_name":"IEEE Transactions on Power Apparatus and Systems","issn_l":"0018-9510","issn":["0018-9510"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Power Apparatus and Systems","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2065687169"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5109745717","display_name":"Y. Taniguchi","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I2801034194","display_name":"Hokuriku Electric Power Company (Japan)","ror":"https://ror.org/00k98ea94","country_code":"JP","type":"company","lineage":["https://openalex.org/I2801034194"]},{"id":"https://openalex.org/I4405274831","display_name":"Hokuriku Electric Co., Ltd. (Japan)","ror":"https://ror.org/02eex4673","country_code":"JP","type":"company","lineage":["https://openalex.org/I4405274831"]},{"id":"https://openalex.org/I4405274925","display_name":"Hokkaido Electric Power Co., Inc. (Japan)","ror":"https://ror.org/02m083m46","country_code":"JP","type":"company","lineage":["https://openalex.org/I4405274925"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Y. Taniguchi","raw_affiliation_strings":["Technical Laboratory, Hokkaido Electrical Power Company, Inc., Toyama, Japan","Technical Laboratory Hokuriku Electric Power Company, Inc"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Technical Laboratory, Hokkaido Electrical Power Company, Inc., Toyama, Japan","institution_ids":["https://openalex.org/I4405274925"]},{"raw_affiliation_string":"Technical Laboratory Hokuriku Electric Power Company, Inc","institution_ids":["https://openalex.org/I2801034194","https://openalex.org/I4405274831"]}]},{"author_position":"middle","author":{"id":null,"display_name":"N. Arai","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I130416959","display_name":"Central Research Institute of Electric Power Industry","ror":"https://ror.org/041jswc25","country_code":"JP","type":"nonprofit","lineage":["https://openalex.org/I130416959"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"N. Arai","raw_affiliation_strings":["Electric Engineering Laboratory Central Research Institute of Electric Power Industry, Electric Power Industry, Tokyo, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electric Engineering Laboratory Central Research Institute of Electric Power Industry, Electric Power Industry, Tokyo, Japan","institution_ids":["https://openalex.org/I130416959"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5110127040","display_name":"Yusuke IMANO","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I130416959","display_name":"Central Research Institute of Electric Power Industry","ror":"https://ror.org/041jswc25","country_code":"JP","type":"nonprofit","lineage":["https://openalex.org/I130416959"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Y. Imano","raw_affiliation_strings":["Electric Engineering Laboratory Central Research Institute of Electric Power Industry, Electric Power Industry, Tokyo, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electric Engineering Laboratory Central Research Institute of Electric Power Industry, Electric Power Industry, Tokyo, Japan","institution_ids":["https://openalex.org/I130416959"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.9525,"has_fulltext":false,"cited_by_count":24,"citation_normalized_percentile":{"value":0.71548199,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":96},"biblio":{"volume":"PAS-98","issue":"1","first_page":"239","last_page":"245"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.0003000000142492354,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12696","display_name":"Icing and De-icing Technologies","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2202","display_name":"Aerospace Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/insulator-contamination","display_name":"insulator contamination","score":0.7620000243186951},{"id":"https://openalex.org/keywords/natural-contamination","display_name":"natural contamination","score":0.6620000004768372},{"id":"https://openalex.org/keywords/salt-deposit-density","display_name":"salt deposit density","score":0.9200000166893005},{"id":"https://openalex.org/keywords/flashover-voltage","display_name":"flashover voltage","score":0.7979999780654907},{"id":"https://openalex.org/keywords/dc-voltage","display_name":"DC voltage","score":0.4699999988079071},{"id":"https://openalex.org/keywords/ac-voltage","display_name":"AC voltage","score":0.9940000176429749},{"id":"https://openalex.org/keywords/insulator-performance","display_name":"insulator performance","score":0.5809999704360962}],"concepts":[{"id":"https://openalex.org/C200769187","wikidata":"https://www.wikidata.org/wiki/Q2360656","display_name":"Arc flash","level":3,"score":0.8715589046478271},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.6856865882873535},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.6061597466468811},{"id":"https://openalex.org/C212702","wikidata":"https://www.wikidata.org/wiki/Q178150","display_name":"Insulator (electricity)","level":2,"score":0.47070977091789246},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.453504353761673},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3951560854911804},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.39507994055747986}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tpas.1979.319524","doi":"https://doi.org/10.1109/tpas.1979.319524","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tpas.1979.319524","pdf_url":null,"source":{"id":"https://openalex.org/S35391503","display_name":"IEEE Transactions on Power Apparatus and Systems","issn_l":"0018-9510","issn":["0018-9510"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Power Apparatus and Systems","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.75,"id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320310509","display_name":"Electric Power Research Institute","ror":"https://ror.org/02dqztz06"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":3,"referenced_works":["https://openalex.org/W1995400115","https://openalex.org/W2027934627","https://openalex.org/W2127677839"],"related_works":["https://openalex.org/W1995400115","https://openalex.org/W2381461635","https://openalex.org/W2075066381","https://openalex.org/W2394339073","https://openalex.org/W2151000591","https://openalex.org/W2104670246","https://openalex.org/W2072245172","https://openalex.org/W2393587369","https://openalex.org/W2065500270","https://openalex.org/W2075874052"],"abstract_inverted_index":{"This":[0],"paper":[1],"describes":[2],"the":[3,8,31,42,46,74],"results":[4],"of":[5,10,13,60],"investigation":[6],"into":[7],"performance":[9],"various":[11],"types":[12],"insulators":[14,61],"energized":[15],"with":[16],"200":[17],"kV":[18,22],"ac":[19,51,79],"and":[20,25,57],"\u00b1280":[21],"dc":[23,71],"voltages":[24],"exposed":[26],"to":[27],"natural":[28],"conditions":[29],"by":[30,65],"seaside":[32],"for":[33,70,78],"about":[34],"five":[35],"years.":[36],"DC":[37],"voltage":[38,52,69],"application":[39],"had":[40],"almost":[41,73],"same":[43,75],"influence":[44],"on":[45],"salt":[47],"deposit":[48,55],"density":[49,56],"as":[50,76],"application.":[53],"Salt":[54],"flashover":[58],"characteristics":[59],"were":[62],"much":[63],"affected":[64],"their":[66],"types.":[67],"Flashover":[68],"is":[72],"that":[77],"in":[80],"rms":[81],"value.":[82]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2065687169","counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2015,"cited_by_count":1}],"updated_date":"2026-11-17T12:49:18.490984","created_date":"2016-06-24T00:00:00"}
