{"id":"https://openalex.org/W2054775786","doi":"https://doi.org/10.1109/t-pas.1976.32119","title":"Partial discharge characteristics of oil-immersed insulation systems under DC, combined AC-DC and DC reversed polarity voltage","display_name":"Partial discharge characteristics of oil-immersed insulation systems under DC, combined AC-DC and DC reversed polarity voltage","alternate_titles":[],"publication_year":1976,"publication_date":"1976-01-01","ids":{"openalex":"https://openalex.org/W2054775786","doi":"https://doi.org/10.1109/t-pas.1976.32119","mag":"2054775786"},"language":"en","primary_location":{"id":"doi:10.1109/t-pas.1976.32119","doi":"https://doi.org/10.1109/t-pas.1976.32119","is_oa":false,"landing_page_url":"https://doi.org/10.1109/t-pas.1976.32119","pdf_url":null,"source":{"id":"https://openalex.org/S35391503","display_name":"IEEE Transactions on Power Apparatus and Systems","issn_l":"0018-9510","issn":["0018-9510"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Power Apparatus and Systems","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2054775786"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"E. Takahashi","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I65143321","display_name":"Hitachi (Japan)","ror":"https://ror.org/02exqgm79","country_code":"JP","type":"company","lineage":["https://openalex.org/I65143321"]}],"countries":["JP"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"E. Takahashi","raw_affiliation_strings":["Hitachi Reseach Laboratory, Hitachi and Limited, Ibaraki, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Hitachi Reseach Laboratory, Hitachi and Limited, Ibaraki, Japan","institution_ids":["https://openalex.org/I65143321"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Y. Tsutsumi","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I65143321","display_name":"Hitachi (Japan)","ror":"https://ror.org/02exqgm79","country_code":"JP","type":"company","lineage":["https://openalex.org/I65143321"]}],"countries":["JP"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Y. Tsutsumi","raw_affiliation_strings":["Hitachi Reseach Laboratory, Hitachi and Limited, Ibaraki, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Hitachi Reseach Laboratory, Hitachi and Limited, Ibaraki, Japan","institution_ids":["https://openalex.org/I65143321"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5050940447","display_name":"Kikuo Okuyama","orcid":"https://orcid.org/0000-0002-1477-1442","observed_orcids":["https://orcid.org/0000-0002-1477-1442"]},"institutions":[{"id":"https://openalex.org/I65143321","display_name":"Hitachi (Japan)","ror":"https://ror.org/02exqgm79","country_code":"JP","type":"company","lineage":["https://openalex.org/I65143321"]}],"countries":["JP"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"K. Okuyama","raw_affiliation_strings":["Kokubu Works, Hitachi and Limited, Ibaraki, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Kokubu Works, Hitachi and Limited, Ibaraki, Japan","institution_ids":["https://openalex.org/I65143321"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5009333954","display_name":"F. Ogata","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I65143321","display_name":"Hitachi (Japan)","ror":"https://ror.org/02exqgm79","country_code":"JP","type":"company","lineage":["https://openalex.org/I65143321"]}],"countries":["JP"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"F. Ogata","raw_affiliation_strings":["Hitachi Works, Hitachi and Limited, Ibaraki, Japan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Hitachi Works, Hitachi and Limited, Ibaraki, Japan","institution_ids":["https://openalex.org/I65143321"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I65143321"],"apc_list":null,"apc_paid":null,"fwci":2.7459,"has_fulltext":false,"cited_by_count":91,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.88060194,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":99},"biblio":{"volume":"95","issue":"1","first_page":"411","last_page":"420"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.9634000062942505,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.9634000062942505,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.035599999129772186,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/partial-discharge","display_name":"partial discharge","score":0.9959999918937683},{"id":"https://openalex.org/keywords/electric-field-mapping","display_name":"electric field mapping","score":0.7760000228881836},{"id":"https://openalex.org/keywords/composite-insulation","display_name":"composite insulation","score":0.7749999761581421},{"id":"https://openalex.org/keywords/transformer-insulation","display_name":"transformer insulation","score":0.9599999785423279}],"concepts":[{"id":"https://openalex.org/C130143024","wikidata":"https://www.wikidata.org/wiki/Q1929972","display_name":"Partial discharge","level":3,"score":0.7498358488082886},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.6260654330253601},{"id":"https://openalex.org/C55942622","wikidata":"https://www.wikidata.org/wiki/Q17105308","display_name":"Polarity reversal","level":3,"score":0.6260321736335754},{"id":"https://openalex.org/C2777361361","wikidata":"https://www.wikidata.org/wiki/Q1112585","display_name":"Polarity (international relations)","level":3,"score":0.6220872402191162},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.576005220413208},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5654932260513306},{"id":"https://openalex.org/C181335627","wikidata":"https://www.wikidata.org/wiki/Q901418","display_name":"Transformer oil","level":4,"score":0.5159433484077454},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.5070960521697998},{"id":"https://openalex.org/C2776620479","wikidata":"https://www.wikidata.org/wiki/Q159241","display_name":"Direct current","level":3,"score":0.45467907190322876},{"id":"https://openalex.org/C119321828","wikidata":"https://www.wikidata.org/wiki/Q1267190","display_name":"Breakdown voltage","level":3,"score":0.44825834035873413},{"id":"https://openalex.org/C2781083372","wikidata":"https://www.wikidata.org/wiki/Q7259687","display_name":"Pulsed DC","level":5,"score":0.4281080365180969},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.20854908227920532},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.13800311088562012},{"id":"https://openalex.org/C171250308","wikidata":"https://www.wikidata.org/wiki/Q11468","display_name":"Nanotechnology","level":1,"score":0.06451535224914551},{"id":"https://openalex.org/C1491633281","wikidata":"https://www.wikidata.org/wiki/Q7868","display_name":"Cell","level":2,"score":0.0},{"id":"https://openalex.org/C22423302","wikidata":"https://www.wikidata.org/wiki/Q898444","display_name":"Sputtering","level":3,"score":0.0},{"id":"https://openalex.org/C55493867","wikidata":"https://www.wikidata.org/wiki/Q7094","display_name":"Biochemistry","level":1,"score":0.0},{"id":"https://openalex.org/C61427134","wikidata":"https://www.wikidata.org/wiki/Q847609","display_name":"Sputter deposition","level":4,"score":0.0},{"id":"https://openalex.org/C19067145","wikidata":"https://www.wikidata.org/wiki/Q1137203","display_name":"Thin film","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/t-pas.1976.32119","doi":"https://doi.org/10.1109/t-pas.1976.32119","is_oa":false,"landing_page_url":"https://doi.org/10.1109/t-pas.1976.32119","pdf_url":null,"source":{"id":"https://openalex.org/S35391503","display_name":"IEEE Transactions on Power Apparatus and Systems","issn_l":"0018-9510","issn":["0018-9510"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Power Apparatus and Systems","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":6,"referenced_works":["https://openalex.org/W1589192059","https://openalex.org/W1984601169","https://openalex.org/W2009992934","https://openalex.org/W2483862081","https://openalex.org/W2795512983","https://openalex.org/W7065884820"],"related_works":["https://openalex.org/W2087536814","https://openalex.org/W2391216706","https://openalex.org/W2095274685","https://openalex.org/W3110744376","https://openalex.org/W2803821089","https://openalex.org/W2766766171","https://openalex.org/W1934701296","https://openalex.org/W2088564026","https://openalex.org/W2041607613","https://openalex.org/W7126018480"],"abstract_inverted_index":{"Breakdown":[0],"characteristics":[1,17,75],"of":[2,18,28,49,54,76],"insulating":[3],"oil,":[4],"under":[5,21,61,79],"combined":[6,22,62,81],"ac-dc":[7,23,63,82],"voltage":[8,24,30,64,69,83],"and":[9,14,25,57,65],"dc":[10,29,41,66],"reversed":[11,67],"polarity":[12,26,68],"voltage,":[13],"partial":[15,73],"discharge":[16,74],"oil-immersed":[19],"insulation,":[20],"revesal":[27],"Were":[31],"made":[32,86],"clear":[33,87],"by":[34,88],"elementary":[35],"experiments.":[36],"After":[37],"that,":[38],"a":[39],"numerical":[40],"field":[42,47,58],"mapping":[43,59],"method":[44],"for":[45],"electric":[46],"analysis":[48],"two-dimensional":[50],"configurations":[51],"which":[52],"consist":[53],"composite":[55],"insulation":[56,78],"methods":[60],"were":[70,84],"proposed.":[71],"Futhermore,":[72],"transformer":[77],"dc,":[80],"experimentally":[85],"practical":[89],"trial":[90],"models.":[91]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2054775786","counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2025,"cited_by_count":4},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":3},{"year":2022,"cited_by_count":4},{"year":2021,"cited_by_count":4},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":6},{"year":2018,"cited_by_count":9},{"year":2017,"cited_by_count":4},{"year":2016,"cited_by_count":5},{"year":2015,"cited_by_count":6},{"year":2014,"cited_by_count":5},{"year":2013,"cited_by_count":4},{"year":2012,"cited_by_count":2}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-06-24T00:00:00"}
