{"id":"https://openalex.org/W2053461996","doi":"https://doi.org/10.1177/1042391508093337","title":"Scale Modeling of Compartment Fires for Structural Fire Testing","display_name":"Scale Modeling of Compartment Fires for Structural Fire Testing","publication_year":2008,"publication_date":"2008-08-01","ids":{"openalex":"https://openalex.org/W2053461996","doi":"https://doi.org/10.1177/1042391508093337","mag":"2053461996"},"language":"en","primary_location":{"id":"doi:10.1177/1042391508093337","doi":"https://doi.org/10.1177/1042391508093337","is_oa":false,"landing_page_url":"https://doi.org/10.1177/1042391508093337","pdf_url":null,"source":{"id":"https://openalex.org/S66393655","display_name":"Journal of Fire Protection Engineering","issn_l":"1042-3915","issn":["1042-3915","1532-172X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","jufo-1","norway-1"],"host_organization":"https://openalex.org/P4310320017","host_organization_name":"SAGE Publishing","host_organization_lineage":["https://openalex.org/P4310320017"],"host_organization_lineage_names":["SAGE Publishing"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Fire Protection Engineering","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100432578","display_name":"Ming Wang","orcid":"https://orcid.org/0000-0002-9618-3061","observed_orcids":["https://orcid.org/0000-0002-9618-3061"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Ming Wang","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5038434158","display_name":"J. Perricone","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"J. Perricone","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5113421761","display_name":"Peter C. Chang","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"P. C. Chang","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5085737870","display_name":"James G. Quintiere","orcid":"https://orcid.org/0000-0002-1863-6563","observed_orcids":["https://orcid.org/0000-0002-1863-6563"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"J. G. Quintiere","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.0367,"has_fulltext":false,"cited_by_count":19,"citation_normalized_percentile":{"value":0.79707507,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":97},"biblio":{"volume":"18","issue":"3","first_page":"223","last_page":"240"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11317","display_name":"Fire dynamics and safety research","score":0.9887999892234802,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11317","display_name":"Fire dynamics and safety research","score":0.9887999892234802,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12102","display_name":"Fire effects on concrete materials","score":0.010700000450015068,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13116","display_name":"Heat Transfer and Numerical Methods","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2206","display_name":"Computational Mechanics"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/compartment-fire","display_name":"compartment fire","score":0.7440000176429749},{"id":"https://openalex.org/keywords/scale-modeling","display_name":"scale modeling","score":0.9409999847412109},{"id":"https://openalex.org/keywords/similarity-laws","display_name":"similarity laws","score":0.7990000247955322},{"id":"https://openalex.org/keywords/structural-fire-resistance","display_name":"fire resistance of structures","score":0.7979999780654907},{"id":"https://openalex.org/keywords/fire-load","display_name":"fire load","score":0.6589999794960022},{"id":"https://openalex.org/keywords/world-trade-center","display_name":"World Trade Center","score":0.7670000195503235},{"id":"https://openalex.org/keywords/september-11-attacks","display_name":"September 11 attacks","score":0.7940000295639038},{"id":"https://openalex.org/keywords/full-scale-fire-tests","display_name":"full-scale fire tests","score":0.6150000095367432}],"concepts":[{"id":"https://openalex.org/C77595967","wikidata":"https://www.wikidata.org/wiki/Q3151013","display_name":"Forensic engineering","level":1,"score":0.5819827914237976},{"id":"https://openalex.org/C3017944768","wikidata":"https://www.wikidata.org/wiki/Q1450463","display_name":"Poison control","level":2,"score":0.5389943718910217},{"id":"https://openalex.org/C124363303","wikidata":"https://www.wikidata.org/wiki/Q898221","display_name":"Fire test","level":2,"score":0.5298362374305725},{"id":"https://openalex.org/C2778755073","wikidata":"https://www.wikidata.org/wiki/Q10858537","display_name":"Scale (ratio)","level":2,"score":0.5292243957519531},{"id":"https://openalex.org/C203635412","wikidata":"https://www.wikidata.org/wiki/Q17007432","display_name":"Compartment (ship)","level":2,"score":0.4823024272918701},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.43315377831459045},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.4167208671569824},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.32450419664382935},{"id":"https://openalex.org/C545542383","wikidata":"https://www.wikidata.org/wiki/Q2751242","display_name":"Medical emergency","level":1,"score":0.21227619051933289},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.1855042576789856},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.1481419801712036},{"id":"https://openalex.org/C205649164","wikidata":"https://www.wikidata.org/wiki/Q1071","display_name":"Geography","level":0,"score":0.10786271095275879},{"id":"https://openalex.org/C58640448","wikidata":"https://www.wikidata.org/wiki/Q42515","display_name":"Cartography","level":1,"score":0.06682735681533813},{"id":"https://openalex.org/C111368507","wikidata":"https://www.wikidata.org/wiki/Q43518","display_name":"Oceanography","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1177/1042391508093337","doi":"https://doi.org/10.1177/1042391508093337","is_oa":false,"landing_page_url":"https://doi.org/10.1177/1042391508093337","pdf_url":null,"source":{"id":"https://openalex.org/S66393655","display_name":"Journal of Fire Protection Engineering","issn_l":"1042-3915","issn":["1042-3915","1532-172X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","jufo-1","norway-1"],"host_organization":"https://openalex.org/P4310320017","host_organization_name":"SAGE Publishing","host_organization_lineage":["https://openalex.org/P4310320017"],"host_organization_lineage_names":["SAGE Publishing"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Fire Protection Engineering","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320306076","display_name":"National Science Foundation","ror":"https://ror.org/021nxhr62"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":6,"referenced_works":["https://openalex.org/W620585309","https://openalex.org/W2028845868","https://openalex.org/W2032786844","https://openalex.org/W2047427986","https://openalex.org/W2066438377","https://openalex.org/W2067145719"],"related_works":["https://openalex.org/W1858729754","https://openalex.org/W2009347736","https://openalex.org/W2007816249","https://openalex.org/W3200524810","https://openalex.org/W4361277682","https://openalex.org/W2028845868","https://openalex.org/W1965737185","https://openalex.org/W2495196751","https://openalex.org/W3092907659","https://openalex.org/W7207585051"],"abstract_inverted_index":{"Current":[0],"design":[1],"for":[2,24,88,126],"fire":[3,40,69,81,92,130,161],"protection":[4],"subjects":[5],"an":[6,47,76],"individual":[7],"structural":[8,38,129],"element":[9],"to":[10,18,79,115,140,158],"a":[11,25,31,56,61,65,67,86,90,109,118,123],"standard":[12],"temperature":[13,104],"profile":[14],"that":[15,152],"is":[16,71,122],"meant":[17],"ensure":[19],"the":[20,37,50,53,95,142,145,153,160,164,167],"element's":[21],"load-carrying":[22],"capacity":[23],"predetermined":[26],"period":[27],"of":[28,49,52,97,101,144,166],"time":[29,106],"during":[30],"fire.":[32,57],"While":[33],"this":[34],"approach":[35],"satisfies":[36],"component's":[39],"resistance":[41],"requirement,":[42],"it":[43],"does":[44],"not":[45],"provide":[46],"understanding":[48],"behavior":[51,63],"structure":[54,165],"in":[55,64,107,117],"To":[58],"fully":[59],"understand":[60],"structure's":[62],"fire,":[66],"full-scale":[68,80,119],"experiment":[70],"necessary.":[72],"Scaled":[73],"experiments":[74],"offer":[75],"economical":[77],"alternative":[78],"experiments.":[82],"This":[83],"paper":[84],"discusses":[85],"method":[87,154],"scaling":[89],"compartment":[91,111],"by":[93],"using":[94],"laws":[96],"similitude.":[98],"The":[99],"profiles":[100],"hot":[102],"gas":[103],"versus":[105],"such":[108],"reduced-scale":[110,128],"will":[112],"be":[113,156],"similar":[114],"those":[116],"compartment,":[120],"which":[121],"necessary":[124],"condition":[125],"conducting":[127],"testing.":[131],"Experimental":[132],"verification":[133],"at":[134],"two":[135],"different":[136],"scales":[137],"are":[138],"performed":[139],"show":[141],"validity":[143],"proposed":[146],"approach.":[147],"It":[148],"has":[149],"been":[150],"shown":[151],"can":[155],"applied":[157],"simulate":[159],"loading":[162],"on":[163,172],"World":[168],"Trade":[169],"Center":[170],"tower":[171],"11":[173],"September,":[174],"2001.":[175]},"counts_by_year":[{"year":2026,"cited_by_count":3},{"year":2025,"cited_by_count":3},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":3},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2015,"cited_by_count":1},{"year":2013,"cited_by_count":2}],"updated_date":"2026-11-07T11:25:07.637180","created_date":"2016-06-24T00:00:00"}
