{"id":"https://openalex.org/W2052238669","doi":"https://doi.org/10.1016/j.firesaf.2011.02.005","title":"Capacity reduction and fire load factors for LRFD of steel columns exposed to fire","display_name":"Capacity reduction and fire load factors for LRFD of steel columns exposed to fire","alternate_titles":[],"publication_year":2011,"publication_date":"2011-04-14","ids":{"openalex":"https://openalex.org/W2052238669","doi":"https://doi.org/10.1016/j.firesaf.2011.02.005","mag":"2052238669"},"language":"en","primary_location":{"id":"doi:10.1016/j.firesaf.2011.02.005","doi":"https://doi.org/10.1016/j.firesaf.2011.02.005","is_oa":false,"landing_page_url":"https://doi.org/10.1016/j.firesaf.2011.02.005","pdf_url":null,"source":{"id":"https://openalex.org/S160215590","display_name":"Fire Safety Journal","issn_l":"0379-7112","issn":["0379-7112","1873-7226"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-a","jufo-2","norway-2","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Fire Safety Journal","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2052238669"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Shahid Iqbal","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I929597975","display_name":"National University of Sciences and Technology","ror":"https://ror.org/03w2j5y17","country_code":"PK","type":"education","lineage":["https://openalex.org/I929597975"]}],"countries":["PK"],"is_corresponding":false,"raw_author_name":"Shahid Iqbal","raw_affiliation_strings":["National University of Sciences and Technology, Islamabad, Pakistan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National University of Sciences and Technology, Islamabad, Pakistan","institution_ids":["https://openalex.org/I929597975"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5048803384","display_name":"Ronald S. Harichandran","orcid":"https://orcid.org/0000-0003-3293-1523","observed_orcids":["https://orcid.org/0000-0003-3293-1523"]},"institutions":[{"id":"https://openalex.org/I87216513","display_name":"Michigan State University","ror":"https://ror.org/05hs6h993","country_code":"US","type":"education","lineage":["https://openalex.org/I87216513"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Ronald S. Harichandran","raw_affiliation_strings":["Department of Civil and Environmental Engineering, Michigan State University, East Lansing, MI 48824-1226, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Civil and Environmental Engineering, Michigan State University, East Lansing, MI 48824-1226, USA","institution_ids":["https://openalex.org/I87216513"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5048803384"],"corresponding_institution_ids":["https://openalex.org/I87216513"],"apc_list":{"value":3770,"currency":"USD","value_usd":3770},"apc_paid":null,"fwci":6.1004,"has_fulltext":false,"cited_by_count":25,"citation_normalized_percentile":{"value":0.95192508,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":88,"max":97},"biblio":{"volume":"46","issue":"5","first_page":"234","last_page":"242"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12102","display_name":"Fire effects on concrete materials","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12102","display_name":"Fire effects on concrete materials","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10713","display_name":"Structural Load-Bearing Analysis","score":0.0007999999797903001,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10928","display_name":"Probabilistic and Robust Engineering Design","score":0.0005000000237487257,"subfield":{"id":"https://openalex.org/subfields/2206","display_name":"Computational Mechanics"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/steel-columns","display_name":"steel columns","score":0.9380000233650208},{"id":"https://openalex.org/keywords/fire-exposure","display_name":"fire exposure","score":0.6690000295639038},{"id":"https://openalex.org/keywords/capacity-reduction-factor","display_name":"capacity reduction factor","score":0.8450000286102295},{"id":"https://openalex.org/keywords/load-and-resistance-factor-design","display_name":"load and resistance factor design","score":0.9850000143051147},{"id":"https://openalex.org/keywords/structural-reliability","display_name":"structural reliability","score":0.6000000238418579},{"id":"https://openalex.org/keywords/active-fire-protection-systems","display_name":"active fire protection systems","score":0.8069999814033508},{"id":"https://openalex.org/keywords/sprinklers","display_name":"sprinklers","score":0.6919999718666077},{"id":"https://openalex.org/keywords/fire-compartment","display_name":"fire compartment","score":0.46399998664855957},{"id":"https://openalex.org/keywords/thermal-insulation","display_name":"thermal insulation","score":0.5590000152587891},{"id":"https://openalex.org/keywords/random-variable","display_name":"random variables","score":0.7680000066757202}],"concepts":[{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.6344494819641113},{"id":"https://openalex.org/C2987912017","wikidata":"https://www.wikidata.org/wiki/Q27787358","display_name":"Fire resistance","level":2,"score":0.6107237339019775},{"id":"https://openalex.org/C111335779","wikidata":"https://www.wikidata.org/wiki/Q3454686","display_name":"Reduction (mathematics)","level":2,"score":0.5739015936851501},{"id":"https://openalex.org/C64839514","wikidata":"https://www.wikidata.org/wiki/Q918306","display_name":"Thermal insulation","level":3,"score":0.532844603061676},{"id":"https://openalex.org/C123453687","wikidata":"https://www.wikidata.org/wiki/Q4371846","display_name":"Strength reduction","level":3,"score":0.5198005437850952},{"id":"https://openalex.org/C2779448613","wikidata":"https://www.wikidata.org/wiki/Q7315963","display_name":"Response factor","level":2,"score":0.5169591307640076},{"id":"https://openalex.org/C2778529468","wikidata":"https://www.wikidata.org/wiki/Q911043","display_name":"Cross laminated timber","level":2,"score":0.4759347438812256},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.45625975728034973},{"id":"https://openalex.org/C3283095","wikidata":"https://www.wikidata.org/wiki/Q1340282","display_name":"Load factor","level":2,"score":0.4522368311882019},{"id":"https://openalex.org/C58874564","wikidata":"https://www.wikidata.org/wiki/Q130768","display_name":"Smoke","level":2,"score":0.4505513310432434},{"id":"https://openalex.org/C122156500","wikidata":"https://www.wikidata.org/wiki/Q41399","display_name":"Fire protection","level":2,"score":0.4493737518787384},{"id":"https://openalex.org/C2781465349","wikidata":"https://www.wikidata.org/wiki/Q1186323","display_name":"Fire performance","level":3,"score":0.44818615913391113},{"id":"https://openalex.org/C126950237","wikidata":"https://www.wikidata.org/wiki/Q7964839","display_name":"Structural load","level":2,"score":0.4349313974380493},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.39134347438812256},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.23677000403404236},{"id":"https://openalex.org/C147176958","wikidata":"https://www.wikidata.org/wiki/Q77590","display_name":"Civil engineering","level":1,"score":0.18658217787742615},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.16490691900253296},{"id":"https://openalex.org/C135628077","wikidata":"https://www.wikidata.org/wiki/Q220184","display_name":"Finite element method","level":2,"score":0.14279022812843323},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.12013188004493713},{"id":"https://openalex.org/C548081761","wikidata":"https://www.wikidata.org/wiki/Q180388","display_name":"Waste management","level":1,"score":0.11298862099647522},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.0},{"id":"https://openalex.org/C2779227376","wikidata":"https://www.wikidata.org/wiki/Q6505497","display_name":"Layer (electronics)","level":2,"score":0.0},{"id":"https://openalex.org/C43617362","wikidata":"https://www.wikidata.org/wiki/Q170050","display_name":"Chromatography","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1016/j.firesaf.2011.02.005","doi":"https://doi.org/10.1016/j.firesaf.2011.02.005","is_oa":false,"landing_page_url":"https://doi.org/10.1016/j.firesaf.2011.02.005","pdf_url":null,"source":{"id":"https://openalex.org/S160215590","display_name":"Fire Safety Journal","issn_l":"0379-7112","issn":["0379-7112","1873-7226"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-a","jufo-2","norway-2","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Fire Safety Journal","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":21,"referenced_works":["https://openalex.org/W240508587","https://openalex.org/W560950621","https://openalex.org/W650322639","https://openalex.org/W1484201893","https://openalex.org/W1972687285","https://openalex.org/W1972984095","https://openalex.org/W1988774442","https://openalex.org/W2002684841","https://openalex.org/W2005852987","https://openalex.org/W2038241608","https://openalex.org/W2040218970","https://openalex.org/W2056889413","https://openalex.org/W2073906720","https://openalex.org/W2083073867","https://openalex.org/W2144217440","https://openalex.org/W2152874621","https://openalex.org/W2480202036","https://openalex.org/W2769368960","https://openalex.org/W2791708204","https://openalex.org/W7048881370","https://openalex.org/W7164639876"],"related_works":["https://openalex.org/W1997115504","https://openalex.org/W2185894503","https://openalex.org/W4224920347","https://openalex.org/W2012439389","https://openalex.org/W3107405004","https://openalex.org/W2556955285","https://openalex.org/W2094236224","https://openalex.org/W2183103143","https://openalex.org/W1964107772"],"abstract_inverted_index":null,"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2052238669","counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2024,"cited_by_count":3},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":3},{"year":2017,"cited_by_count":2},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":3},{"year":2013,"cited_by_count":3},{"year":2012,"cited_by_count":1}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-06-24T00:00:00"}