{"id":"https://openalex.org/W2045679481","doi":"https://doi.org/10.1117/12.477987","title":"Benefits and applications of programmable spectral devices in confocal microscopes","display_name":"Benefits and applications of programmable spectral devices in confocal microscopes","publication_year":2003,"publication_date":"2003-07-02","ids":{"openalex":"https://openalex.org/W2045679481","doi":"https://doi.org/10.1117/12.477987","mag":"2045679481"},"language":"en","primary_location":{"id":"doi:10.1117/12.477987","doi":"https://doi.org/10.1117/12.477987","is_oa":false,"landing_page_url":"https://doi.org/10.1117/12.477987","pdf_url":null,"source":{"id":"https://openalex.org/S183492911","display_name":"Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE","issn_l":"0277-786X","issn":["0277-786X","1996-756X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","norway-1"],"host_organization":"https://openalex.org/P4310315543","host_organization_name":"SPIE","host_organization_lineage":["https://openalex.org/P4310315543"],"host_organization_lineage_names":["SPIE"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"SPIE Proceedings","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5110856164","display_name":"Rolf Theodor Borlinghaus","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4405273446","display_name":"Leica Microsystems (Germany)","ror":"https://ror.org/05v20se24","country_code":"DE","type":"company","lineage":["https://openalex.org/I4405273446"]}],"countries":["DE"],"is_corresponding":true,"raw_author_name":"Rolf Borlinghaus","raw_affiliation_strings":["Leica Microsystems Heidelberg GmbH (Germany)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Leica Microsystems Heidelberg GmbH (Germany)","institution_ids":["https://openalex.org/I4405273446"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5110856164"],"corresponding_institution_ids":["https://openalex.org/I4405273446"],"apc_list":null,"apc_paid":null,"fwci":2.5601,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.87997166,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"4964","issue":null,"first_page":"7","last_page":"7"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T13493","display_name":"Optical and Acousto-Optic Technologies","score":0.7612000107765198,"subfield":{"id":"https://openalex.org/subfields/3107","display_name":"Atomic and Molecular Physics, and Optics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T13493","display_name":"Optical and Acousto-Optic Technologies","score":0.7612000107765198,"subfield":{"id":"https://openalex.org/subfields/3107","display_name":"Atomic and Molecular Physics, and Optics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10540","display_name":"Advanced Fluorescence Microscopy Techniques","score":0.20839999616146088,"subfield":{"id":"https://openalex.org/subfields/1304","display_name":"Biophysics"},"field":{"id":"https://openalex.org/fields/13","display_name":"Biochemistry, Genetics and Molecular Biology"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},{"id":"https://openalex.org/T11517","display_name":"Advanced optical system design","score":0.0071000000461936,"subfield":{"id":"https://openalex.org/subfields/3107","display_name":"Atomic and Molecular Physics, and Optics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/confocal-microscopy","display_name":"confocal microscopy","score":0.8859999775886536},{"id":"https://openalex.org/keywords/acousto-optic-filter","display_name":"acousto-optic filter","score":0.890999972820282},{"id":"https://openalex.org/keywords/emission-filter","display_name":"emission filter","score":0.9869999885559082},{"id":"https://openalex.org/keywords/dichroic-beam-splitter","display_name":"dichroic beam splitter","score":0.8889999985694885},{"id":"https://openalex.org/keywords/spectral-scanning","display_name":"spectral scanning","score":0.7419999837875366},{"id":"https://openalex.org/keywords/signal-to-noise-ratio","display_name":"signal-to-noise ratio","score":0.8560000061988831},{"id":"https://openalex.org/keywords/photobleaching","display_name":"photobleaching","score":0.8600000143051147},{"id":"https://openalex.org/keywords/fluorescence-microscopy","display_name":"fluorescence microscopy","score":0.7210000157356262}],"concepts":[{"id":"https://openalex.org/C67649825","wikidata":"https://www.wikidata.org/wiki/Q196538","display_name":"Microscope","level":2,"score":0.6467966437339783},{"id":"https://openalex.org/C31332276","wikidata":"https://www.wikidata.org/wiki/Q899750","display_name":"Photobleaching","level":3,"score":0.6222977042198181},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.6176184415817261},{"id":"https://openalex.org/C83581075","wikidata":"https://www.wikidata.org/wiki/Q1361503","display_name":"Excitation","level":2,"score":0.5851608514785767},{"id":"https://openalex.org/C94915269","wikidata":"https://www.wikidata.org/wiki/Q1834857","display_name":"Detector","level":2,"score":0.5650866031646729},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5595645904541016},{"id":"https://openalex.org/C19819980","wikidata":"https://www.wikidata.org/wiki/Q947542","display_name":"Beam splitter","level":3,"score":0.5404120683670044},{"id":"https://openalex.org/C45613198","wikidata":"https://www.wikidata.org/wiki/Q1134091","display_name":"Optical filter","level":2,"score":0.48539862036705017},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.48149144649505615},{"id":"https://openalex.org/C136009344","wikidata":"https://www.wikidata.org/wiki/Q336201","display_name":"Confocal","level":2,"score":0.4603343904018402},{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.4374169707298279},{"id":"https://openalex.org/C106131492","wikidata":"https://www.wikidata.org/wiki/Q3072260","display_name":"Filter (signal processing)","level":2,"score":0.4136267900466919},{"id":"https://openalex.org/C147080431","wikidata":"https://www.wikidata.org/wiki/Q1074953","display_name":"Microscopy","level":2,"score":0.41052132844924927},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.2973133325576782},{"id":"https://openalex.org/C520434653","wikidata":"https://www.wikidata.org/wiki/Q38867","display_name":"Laser","level":2,"score":0.2581120729446411},{"id":"https://openalex.org/C91881484","wikidata":"https://www.wikidata.org/wiki/Q191807","display_name":"Fluorescence","level":2,"score":0.20651981234550476},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.15793779492378235},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.1147882342338562},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.07950851321220398},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1117/12.477987","doi":"https://doi.org/10.1117/12.477987","is_oa":false,"landing_page_url":"https://doi.org/10.1117/12.477987","pdf_url":null,"source":{"id":"https://openalex.org/S183492911","display_name":"Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE","issn_l":"0277-786X","issn":["0277-786X","1996-756X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","norway-1"],"host_organization":"https://openalex.org/P4310315543","host_organization_name":"SPIE","host_organization_lineage":["https://openalex.org/P4310315543"],"host_organization_lineage_names":["SPIE"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"SPIE Proceedings","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W1996595144","https://openalex.org/W1989967199","https://openalex.org/W2034971315","https://openalex.org/W1986731140","https://openalex.org/W1968647501","https://openalex.org/W1802451680","https://openalex.org/W181857375","https://openalex.org/W2027112944","https://openalex.org/W2126816516","https://openalex.org/W2032337137"],"abstract_inverted_index":{"Recent":[0],"developement":[1],"in":[2,31],"confocal":[3],"microscope":[4],"systems":[5],"allow":[6,53,79,118],"to":[7,133,143],"tune":[8],"the":[9,24,63],"spectral":[10,97],"characteristics":[11],"of":[12,56,66,81,121,155],"those":[13],"elements":[14],"which":[15,27,46,78],"separate":[16],"excitation":[17,57,64,122],"and":[18,52,88,117],"emission.":[19],"The":[20,92],"new":[21],"devices":[22,51,130],"replace":[23],"classical":[25],"filter-devices,":[26],"have":[28,39,71,103],"been":[29,40,72,104],"used":[30],"fluorescence":[32],"microscopy":[33],"for":[34,85],"many":[35],"years.":[36],"Excitation":[37],"filters":[38,70],"replaced":[41,73,105],"by":[42,74,106],"acousto":[43,107],"optical":[44,108],"filters,":[45],"work":[47],"as":[48,59,61],"multichannel":[49],"dimmer":[50],"fine":[54],"tuning":[55,62,80],"energy":[58],"well":[60],"ratio":[65,145],"multiple":[67],"excitations.":[68],"Emission":[69],"tunable":[75],"multiband":[76,93],"detectors,":[77],"emission":[82],"band":[83,90],"width":[84],"higher":[86],"efficiency":[87,116],"better":[89,135],"separation.":[91],"detector":[94],"also":[95],"allows":[96],"scanning":[98],"modes.":[99],"Dichroitic":[100],"beam":[101,109],"splitters":[102,110],"(AOBS)":[111],"giving":[112,139],"significantly":[113],"increased":[114],"signal":[115,142],"fast":[119],"switching":[120],"modes":[123],"without":[124],"moving":[125],"mechanical":[126],"parts.":[127],"All":[128],"three":[129],"together":[131],"lead":[132],"much":[134,147],"primary":[136],"images,":[137],"either":[138],"highly":[140],"improved":[141],"noise":[144],"or":[146],"less":[148],"photobleaching":[149],"(which":[150],"is":[151],"identically":[152],"with":[153],"viability":[154],"life":[156],"samples).":[157]},"counts_by_year":[],"updated_date":"2026-09-25T08:18:29.962427","created_date":"2016-06-24T00:00:00"}
