{"id":"https://openalex.org/W2044935899","doi":"https://doi.org/10.1088/0967-3334/35/9/1913","title":"Improved motion robustness of remote-PPG by using the blood volume pulse signature","display_name":"Improved motion robustness of remote-PPG by using the blood volume pulse signature","publication_year":2014,"publication_date":"2014-08-27","ids":{"openalex":"https://openalex.org/W2044935899","doi":"https://doi.org/10.1088/0967-3334/35/9/1913","mag":"2044935899","pmid":"https://pubmed.ncbi.nlm.nih.gov/25159049"},"language":"en","primary_location":{"id":"doi:10.1088/0967-3334/35/9/1913","doi":"https://doi.org/10.1088/0967-3334/35/9/1913","is_oa":true,"landing_page_url":"https://doi.org/10.1088/0967-3334/35/9/1913","pdf_url":"https://iopscience.iop.org/article/10.1088/0967-3334/35/9/1913/pdf","source":{"id":"https://openalex.org/S3164724","display_name":"Physiological Measurement","issn_l":"0967-3334","issn":["0967-3334","1361-6579"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-c","doyens","jufo-1","ki-jl-1","medline","norway-1","poland-100","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310320083","host_organization_name":"IOP Publishing","host_organization_lineage":["https://openalex.org/P4310320083","https://openalex.org/P4310311669"],"host_organization_lineage_names":["IOP Publishing","Institute of Physics"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Physiological Measurement","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref","pubmed"],"open_access":{"is_oa":true,"oa_status":"bronze","oa_url":"https://iopscience.iop.org/article/10.1088/0967-3334/35/9/1913/pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5037310619","display_name":"G. de Haan","orcid":"https://orcid.org/0000-0001-8651-5424","observed_orcids":["https://orcid.org/0000-0001-8651-5424","https://orcid.org/0000-0002-3055-3920"]},"institutions":[{"id":"https://openalex.org/I4210122849","display_name":"Philips (Netherlands)","ror":"https://ror.org/02p2bgp27","country_code":"NL","type":"company","lineage":["https://openalex.org/I4210122849"]},{"id":"https://openalex.org/I4210163196","display_name":"Signify (Netherlands)","ror":"https://ror.org/0532vdr17","country_code":"NL","type":"company","lineage":["https://openalex.org/I4210163196"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"G de Haan","raw_affiliation_strings":["Philips Group Innovation, Research, High Tech Campus 36, 5656AE Eindhoven, The Netherlands"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Philips Group Innovation, Research, High Tech Campus 36, 5656AE Eindhoven, The Netherlands","institution_ids":["https://openalex.org/I4210122849","https://openalex.org/I4210163196"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5005220942","display_name":"Arno J. van Leest","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I927257375","display_name":"ASML (Netherlands)","ror":"https://ror.org/01vxknj13","country_code":"NL","type":"company","lineage":["https://openalex.org/I4210092504","https://openalex.org/I927257375"]}],"countries":["NL"],"is_corresponding":true,"raw_author_name":"A van Leest","raw_affiliation_strings":["ASML, Flight Forum 1900, 5657EZ Eindhoven, The Netherlands"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"ASML, Flight Forum 1900, 5657EZ Eindhoven, The Netherlands","institution_ids":["https://openalex.org/I927257375"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5005220942"],"corresponding_institution_ids":["https://openalex.org/I927257375"],"apc_list":{"value":3325,"currency":"USD","value_usd":3325},"apc_paid":null,"fwci":6.9838,"has_fulltext":true,"cited_by_count":505,"citation_normalized_percentile":{"value":0.97938345,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":99,"max":100},"biblio":{"volume":"35","issue":"9","first_page":"1913","last_page":"1926"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10745","display_name":"Heart Rate Variability and Autonomic Control","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10977","display_name":"Optical Imaging and Spectroscopy Techniques","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/remote-photoplethysmography","display_name":"remote photoplethysmography","score":1.0},{"id":"https://openalex.org/keywords/blood-volume-pulse","display_name":"blood volume pulse","score":0.7940000295639038},{"id":"https://openalex.org/keywords/motion-robustness","display_name":"motion robustness","score":0.9940000176429749},{"id":"https://openalex.org/keywords/rgb-color-space","display_name":"RGB color space","score":0.5320000052452087},{"id":"https://openalex.org/keywords/pulse-rate-detection","display_name":"pulse rate detection","score":0.6850000023841858},{"id":"https://openalex.org/keywords/signal-to-noise-ratio","display_name":"signal-to-noise ratio","score":0.8610000014305115},{"id":"https://openalex.org/keywords/non-contact-vital-sign-monitoring","display_name":"non-contact vital sign monitoring","score":0.7239999771118164},{"id":"https://openalex.org/keywords/exercise-monitoring","display_name":"exercise monitoring","score":0.4950000047683716}],"concepts":[{"id":"https://openalex.org/C116390426","wikidata":"https://www.wikidata.org/wiki/Q7187885","display_name":"Photoplethysmogram","level":3,"score":0.8312262892723083},{"id":"https://openalex.org/C63479239","wikidata":"https://www.wikidata.org/wiki/Q7353546","display_name":"Robustness (evolution)","level":3,"score":0.7641956210136414},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.6035300493240356},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.5986068844795227},{"id":"https://openalex.org/C82990744","wikidata":"https://www.wikidata.org/wiki/Q166194","display_name":"RGB color model","level":2,"score":0.5896884202957153},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5431635975837708},{"id":"https://openalex.org/C163204269","wikidata":"https://www.wikidata.org/wiki/Q355263","display_name":"Chrominance","level":3,"score":0.5126268267631531},{"id":"https://openalex.org/C2908647359","wikidata":"https://www.wikidata.org/wiki/Q2625603","display_name":"Population","level":2,"score":0.4111577272415161},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.36938929557800293},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.3435804545879364},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.18946310877799988},{"id":"https://openalex.org/C106131492","wikidata":"https://www.wikidata.org/wiki/Q3072260","display_name":"Filter (signal processing)","level":2,"score":0.154249906539917},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.0},{"id":"https://openalex.org/C55493867","wikidata":"https://www.wikidata.org/wiki/Q7094","display_name":"Biochemistry","level":1,"score":0.0},{"id":"https://openalex.org/C104317684","wikidata":"https://www.wikidata.org/wiki/Q7187","display_name":"Gene","level":2,"score":0.0},{"id":"https://openalex.org/C73313986","wikidata":"https://www.wikidata.org/wiki/Q355386","display_name":"Luminance","level":2,"score":0.0},{"id":"https://openalex.org/C99454951","wikidata":"https://www.wikidata.org/wiki/Q932068","display_name":"Environmental health","level":1,"score":0.0}],"mesh":[],"locations_count":8,"locations":[{"id":"doi:10.1088/0967-3334/35/9/1913","doi":"https://doi.org/10.1088/0967-3334/35/9/1913","is_oa":true,"landing_page_url":"https://doi.org/10.1088/0967-3334/35/9/1913","pdf_url":"https://iopscience.iop.org/article/10.1088/0967-3334/35/9/1913/pdf","source":{"id":"https://openalex.org/S3164724","display_name":"Physiological Measurement","issn_l":"0967-3334","issn":["0967-3334","1361-6579"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-c","doyens","jufo-1","ki-jl-1","medline","norway-1","poland-100","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310320083","host_organization_name":"IOP Publishing","host_organization_lineage":["https://openalex.org/P4310320083","https://openalex.org/P4310311669"],"host_organization_lineage_names":["IOP Publishing","Institute of Physics"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Physiological Measurement","raw_type":"journal-article"},{"id":"pmid:25159049","doi":null,"is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/25159049","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Physiological measurement","raw_type":"Journal Article"},{"id":"pmh:oai:pure.tue.nl:openaire/ddf3c25f-8acc-4a62-ba5f-3f0568d40cb3","doi":null,"is_oa":true,"landing_page_url":"https://research.tue.nl/en/publications/ddf3c25f-8acc-4a62-ba5f-3f0568d40cb3","pdf_url":null,"source":{"id":"https://openalex.org/S4406922641","display_name":"TU/e Research Portal","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Haan, de, G & Leest, van, A J 2014, 'Improved motion robustness of remote-PPG by using the blood volume pulse signature', Physiological Measurement, vol. 35, no. 9, pp. 1913-1926. https://doi.org/10.1088/0967-3334/35/9/1913","raw_type":"info:eu-repo/semantics/article"},{"id":"pmh:oai:CiteSeerX.psu:10.1.1.727.2130","doi":null,"is_oa":false,"landing_page_url":"http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.727.2130","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"http://www.ics.ele.tue.nl/%7Edehaan/pdf/171_SignatureBasedPPG.pdf","raw_type":"text"},{"id":"pmh:787188","doi":null,"is_oa":false,"landing_page_url":"http://library.tue.nl/csp/dare/LinkToRepository.csp?recordnumber=787188","pdf_url":null,"source":{"id":"https://openalex.org/S4406922641","display_name":"TU/e Research Portal","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"ISSN:0967-3334","raw_type":"Article / Letter to the editor"},{"id":"pmh:oai:library.tue.nl:787188","doi":null,"is_oa":false,"landing_page_url":"http://repository.tue.nl/787188","pdf_url":null,"source":{"id":"https://openalex.org/S4406922641","display_name":"TU/e Research Portal","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"ISSN:0967-3334","raw_type":"Article / Letter to the editor"},{"id":"pmh:tue:oai:library.tue.nl:787188","doi":null,"is_oa":false,"landing_page_url":"http://repository.tue.nl/787188","pdf_url":null,"source":{"id":"https://openalex.org/S4406922641","display_name":"TU/e Research Portal","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Physiological Measurement Physiological Measurement Physiological Measurement Physiological Measurement Physiological Measurement, 35(9), 1913","raw_type":"info:eu-repo/semantics/article"},{"id":"pmh:tue:oai:pure.tue.nl:publications/ddf3c25f-8acc-4a62-ba5f-3f0568d40cb3","doi":null,"is_oa":true,"landing_page_url":"https://research.tue.nl/nl/publications/ddf3c25f-8acc-4a62-ba5f-3f0568d40cb3","pdf_url":null,"source":{"id":"https://openalex.org/S4406922641","display_name":"TU/e Research Portal","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Physiological Measurement, 35(9), 1913 - 1926. Institute of Physics","raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":{"id":"doi:10.1088/0967-3334/35/9/1913","doi":"https://doi.org/10.1088/0967-3334/35/9/1913","is_oa":true,"landing_page_url":"https://doi.org/10.1088/0967-3334/35/9/1913","pdf_url":"https://iopscience.iop.org/article/10.1088/0967-3334/35/9/1913/pdf","source":{"id":"https://openalex.org/S3164724","display_name":"Physiological Measurement","issn_l":"0967-3334","issn":["0967-3334","1361-6579"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-c","doyens","jufo-1","ki-jl-1","medline","norway-1","poland-100","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310320083","host_organization_name":"IOP Publishing","host_organization_lineage":["https://openalex.org/P4310320083","https://openalex.org/P4310311669"],"host_organization_lineage_names":["IOP Publishing","Institute of Physics"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Physiological Measurement","raw_type":"journal-article"},"sustainable_development_goals":[{"display_name":"Good health and well-being","id":"https://metadata.un.org/sdg/3","score":0.46810001134872437}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2044935899.pdf","grobid_xml":"https://content.openalex.org/works/W2044935899.grobid-xml"},"referenced_works_count":16,"referenced_works":["https://openalex.org/W1528784850","https://openalex.org/W1967067747","https://openalex.org/W1971882374","https://openalex.org/W1984026713","https://openalex.org/W1984554603","https://openalex.org/W1995581167","https://openalex.org/W2003922338","https://openalex.org/W2022351629","https://openalex.org/W2069692225","https://openalex.org/W2083872334","https://openalex.org/W2087766611","https://openalex.org/W2102232552","https://openalex.org/W2117320287","https://openalex.org/W2135220085","https://openalex.org/W2417611892","https://openalex.org/W4285719527"],"related_works":["https://openalex.org/W7100450289","https://openalex.org/W2069692225","https://openalex.org/W2128585298","https://openalex.org/W2002282659","https://openalex.org/W3020054131","https://openalex.org/W4415821014","https://openalex.org/W2548034104","https://openalex.org/W2807590430","https://openalex.org/W2060667206","https://openalex.org/W2595505933"],"abstract_inverted_index":{"Remote":[0],"photoplethysmography":[1],"(rPPG)":[2],"enables":[3],"contact-free":[4],"monitoring":[5],"of":[6,41,77,136,145,165,179,195,214,238],"the":[7,18,29,37,48,78,82,104,116,141,156,160,172,177,180,202,207,212,215,228,235,239],"blood":[8,25,43],"volume":[9,26],"pulse":[10],"using":[11],"a":[12,53,58,68,98,127,134,192],"color":[13],"camera.":[14,83],"Essentially,":[15],"it":[16],"detects":[17],"minute":[19],"optical":[20,79],"absorption":[21,39],"changes":[22],"caused":[23],"by":[24],"variations":[27,49],"in":[28,57,81,126,155],"skin.":[30],"In":[31],"this":[32,87],"paper,":[33],"we":[34,119,139,199],"show":[35,85],"that":[36,86,201],"different":[38],"spectra":[40],"arterial":[42],"and":[44,72,112],"bloodless":[45],"skin":[46],"cause":[47],"to":[50,92,169,187,206,222,232],"occur":[51],"along":[52],"very":[54],"specific":[55],"vector":[56,63],"normalized":[59],"RGB-space.":[60],"The":[61],"exact":[62],"can":[64,89],"be":[65,90],"determined":[66],"for":[67,73,163,171],"given":[69,74],"light":[70],"spectrum":[71],"transfer":[75],"characteristics":[76],"filters":[80],"We":[84,226],"'signature'":[88],"used":[91],"design":[93],"an":[94],"rPPG":[95,149],"algorithm":[96],"with":[97,129],"much":[99],"better":[100,114],"motion":[101,143,230],"robustness":[102,144,231],"than":[103,115],"recent":[105],"methods":[106,118],"based":[107],"on":[108,133],"blind":[109],"source":[110],"separation,":[111],"even":[113],"chrominance-based":[117],"published":[120],"earlier.":[121],"Using":[122],"six":[123],"videos":[124],"recorded":[125],"gym,":[128],"four":[130],"subjects":[131,198],"exercising":[132],"range":[135],"fitness":[137],"devices,":[138],"confirm":[140],"superior":[142],"our":[146],"newly":[147],"proposed":[148],"methods.":[150],"A":[151],"simple":[152],"peak":[153],"detector":[154],"frequency":[157],"domain":[158],"returns":[159],"correct":[161],"pulse-rate":[162],"68%":[164],"total":[166],"measurements":[167],"compared":[168],"60%":[170],"best":[173,208],"previous":[174,209],"method,":[175,210],"while":[176],"SNR":[178,213],"pulse-signal":[181,216],"improves":[182],"from":[183,218],"-":[184,188],"5":[185],"dB":[186,221],"4":[189],"dB.":[190,225],"For":[191],"large":[193],"population":[194],"117":[196],"stationary":[197],"prove":[200],"accuracy":[203],"is":[204],"comparable":[205],"although":[211],"drops":[217],"+":[219,223],"8.4":[220],"7.6":[224],"expect":[227],"improved":[229],"significantly":[233],"widen":[234],"application":[236],"scope":[237],"rPPG-technique.":[240]},"counts_by_year":[{"year":2026,"cited_by_count":46},{"year":2025,"cited_by_count":79},{"year":2024,"cited_by_count":67},{"year":2023,"cited_by_count":57},{"year":2022,"cited_by_count":70},{"year":2021,"cited_by_count":42},{"year":2020,"cited_by_count":30},{"year":2019,"cited_by_count":34},{"year":2018,"cited_by_count":34},{"year":2017,"cited_by_count":26},{"year":2016,"cited_by_count":12},{"year":2015,"cited_by_count":8}],"updated_date":"2026-11-07T11:25:07.637180","created_date":"2016-06-24T00:00:00"}
