{"id":"https://openalex.org/W2041796966","doi":"https://doi.org/10.1364/cleo_si.2011.cwl1","title":"Opto-fluidic Detection Platform for Pathogen Detection in Water","display_name":"Opto-fluidic Detection Platform for Pathogen Detection in Water","publication_year":2011,"publication_date":"2011-01-01","ids":{"openalex":"https://openalex.org/W2041796966","doi":"https://doi.org/10.1364/cleo_si.2011.cwl1","mag":"2041796966"},"language":"en","primary_location":{"id":"doi:10.1364/cleo_si.2011.cwl1","doi":"https://doi.org/10.1364/cleo_si.2011.cwl1","is_oa":false,"landing_page_url":"https://doi.org/10.1364/cleo_si.2011.cwl1","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"CLEO:2011 - Laser Applications to Photonic Applications","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5028030627","display_name":"P. Kiesel","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I173498003","display_name":"Palo Alto Research Center","ror":"https://ror.org/0529fxt39","country_code":"US","type":"facility","lineage":["https://openalex.org/I173498003","https://openalex.org/I4210132870"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Peter Kiesel","raw_affiliation_strings":["Palo Alto Research Center, 3333 Coyote Hill Road, Palo Alto, CA 94304, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Palo Alto Research Center, 3333 Coyote Hill Road, Palo Alto, CA 94304, USA","institution_ids":["https://openalex.org/I173498003"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5108398406","display_name":"Joerg Martini","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I173498003","display_name":"Palo Alto Research Center","ror":"https://ror.org/0529fxt39","country_code":"US","type":"facility","lineage":["https://openalex.org/I173498003","https://openalex.org/I4210132870"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Joerg Martini","raw_affiliation_strings":["Palo Alto Research Center, 3333 Coyote Hill Road, Palo Alto, CA 94304, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Palo Alto Research Center, 3333 Coyote Hill Road, Palo Alto, CA 94304, USA","institution_ids":["https://openalex.org/I173498003"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5046938142","display_name":"Malte Huck","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I173498003","display_name":"Palo Alto Research Center","ror":"https://ror.org/0529fxt39","country_code":"US","type":"facility","lineage":["https://openalex.org/I173498003","https://openalex.org/I4210132870"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Malte Huck","raw_affiliation_strings":["Palo Alto Research Center, 3333 Coyote Hill Road, Palo Alto, CA 94304, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Palo Alto Research Center, 3333 Coyote Hill Road, Palo Alto, CA 94304, USA","institution_ids":["https://openalex.org/I173498003"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5045021865","display_name":"Michael I. Recht","orcid":"https://orcid.org/0000-0001-9917-2643","observed_orcids":["https://orcid.org/0000-0001-9917-2643"]},"institutions":[{"id":"https://openalex.org/I173498003","display_name":"Palo Alto Research Center","ror":"https://ror.org/0529fxt39","country_code":"US","type":"facility","lineage":["https://openalex.org/I173498003","https://openalex.org/I4210132870"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Michael Recht","raw_affiliation_strings":["Palo Alto Research Center, 3333 Coyote Hill Road, Palo Alto, CA 94304, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Palo Alto Research Center, 3333 Coyote Hill Road, Palo Alto, CA 94304, USA","institution_ids":["https://openalex.org/I173498003"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5056449861","display_name":"Marshall W. Bern","orcid":"https://orcid.org/0000-0003-0342-9390","observed_orcids":["https://orcid.org/0000-0003-0342-9390"]},"institutions":[{"id":"https://openalex.org/I173498003","display_name":"Palo Alto Research Center","ror":"https://ror.org/0529fxt39","country_code":"US","type":"facility","lineage":["https://openalex.org/I173498003","https://openalex.org/I4210132870"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Marshall Bern","raw_affiliation_strings":["Palo Alto Research Center, 3333 Coyote Hill Road, Palo Alto, CA 94304, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Palo Alto Research Center, 3333 Coyote Hill Road, Palo Alto, CA 94304, USA","institution_ids":["https://openalex.org/I173498003"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5007271458","display_name":"N. M. Johnson","orcid":"https://orcid.org/0009-0001-5788-6266","observed_orcids":["https://orcid.org/0009-0001-5788-6266"]},"institutions":[{"id":"https://openalex.org/I173498003","display_name":"Palo Alto Research Center","ror":"https://ror.org/0529fxt39","country_code":"US","type":"facility","lineage":["https://openalex.org/I173498003","https://openalex.org/I4210132870"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Noble Johnson","raw_affiliation_strings":["Palo Alto Research Center, 3333 Coyote Hill Road, Palo Alto, CA 94304, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Palo Alto Research Center, 3333 Coyote Hill Road, Palo Alto, CA 94304, USA","institution_ids":["https://openalex.org/I173498003"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I173498003"],"apc_list":null,"apc_paid":null,"fwci":0.5579,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.62580815,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":93},"biblio":{"volume":null,"issue":null,"first_page":"CWL1","last_page":"CWL1"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11393","display_name":"Biosensors and Analytical Detection","score":0.486299991607666,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11393","display_name":"Biosensors and Analytical Detection","score":0.486299991607666,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11255","display_name":"Microfluidic and Bio-sensing Technologies","score":0.3734999895095825,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10412","display_name":"Microfluidic and Capillary Electrophoresis Applications","score":0.06469999998807907,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/pathogen-detection","display_name":"pathogen detection","score":0.890999972820282},{"id":"https://openalex.org/keywords/drinking-water","display_name":"drinking water","score":0.718999981880188},{"id":"https://openalex.org/keywords/pin-photodiode","display_name":"PIN photodiode","score":0.8939999938011169},{"id":"https://openalex.org/keywords/detection-limit","display_name":"detection limit","score":0.8029999732971191},{"id":"https://openalex.org/keywords/water-quality-monitoring","display_name":"water quality monitoring","score":0.5}],"concepts":[{"id":"https://openalex.org/C132651336","wikidata":"https://www.wikidata.org/wiki/Q185571","display_name":"Fluidics","level":2,"score":0.8226823806762695},{"id":"https://openalex.org/C119128265","wikidata":"https://www.wikidata.org/wiki/Q900165","display_name":"Detection limit","level":2,"score":0.6004494428634644},{"id":"https://openalex.org/C751236","wikidata":"https://www.wikidata.org/wiki/Q175943","display_name":"Photodiode","level":2,"score":0.5662398934364319},{"id":"https://openalex.org/C8673954","wikidata":"https://www.wikidata.org/wiki/Q138845","display_name":"Microfluidics","level":2,"score":0.5124917030334473},{"id":"https://openalex.org/C141290920","wikidata":"https://www.wikidata.org/wiki/Q7099052","display_name":"Optofluidics","level":3,"score":0.4788386821746826},{"id":"https://openalex.org/C2776460866","wikidata":"https://www.wikidata.org/wiki/Q170065","display_name":"Pathogen","level":2,"score":0.47220999002456665},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3276633024215698},{"id":"https://openalex.org/C171250308","wikidata":"https://www.wikidata.org/wiki/Q11468","display_name":"Nanotechnology","level":1,"score":0.315234899520874},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.27298712730407715},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.2653755843639374},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.19612956047058105},{"id":"https://openalex.org/C43617362","wikidata":"https://www.wikidata.org/wiki/Q170050","display_name":"Chromatography","level":1,"score":0.11106142401695251},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.10890662670135498},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.10319498181343079},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.09902045130729675},{"id":"https://openalex.org/C89423630","wikidata":"https://www.wikidata.org/wiki/Q7193","display_name":"Microbiology","level":1,"score":0.09837192296981812}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1364/cleo_si.2011.cwl1","doi":"https://doi.org/10.1364/cleo_si.2011.cwl1","is_oa":false,"landing_page_url":"https://doi.org/10.1364/cleo_si.2011.cwl1","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"CLEO:2011 - Laser Applications to Photonic Applications","raw_type":"proceedings-article"},{"id":"mag:3146650373","doi":null,"is_oa":false,"landing_page_url":"http://yadda.icm.edu.pl/yadda/element/bwmeta1.element.ieee-000005950763","pdf_url":null,"source":{"id":"https://openalex.org/S4306418073","display_name":"Conference on Lasers and Electro-Optics","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"Conference on Lasers and Electro-Optics","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.7778000235557556,"id":"https://metadata.un.org/sdg/6","display_name":"Clean water and sanitation"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2037254648","https://openalex.org/W2050578750","https://openalex.org/W1594772234","https://openalex.org/W3015323361","https://openalex.org/W7061265131","https://openalex.org/W2474414831","https://openalex.org/W1981331121","https://openalex.org/W2158880234","https://openalex.org/W2042451605","https://openalex.org/W4225129762"],"abstract_inverted_index":{"We":[0],"prototyped":[1],"a":[2,16,22],"compact":[3],"micro-fluidic":[4],"based":[5],"flow":[6],"cytometer":[7],"for":[8,18],"pathogen":[9],"detection":[10,19,23],"in":[11],"water.":[12],"The":[13],"system":[14],"uses":[15],"pin-photodiode":[17],"and":[20,31],"yielded":[21],"limit":[24],"of":[25],"~200MEPE,":[26],"sufficient":[27],"to":[28],"reliably":[29],"identify":[30],"count":[32],"specifically-tagged":[33],"pathogens.":[34]},"counts_by_year":[{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2013,"cited_by_count":1}],"updated_date":"2026-10-17T09:40:24.721904","created_date":"2016-06-24T00:00:00"}
