{"id":"https://openalex.org/W2034492151","doi":"https://doi.org/10.1049/piee.1974.0193","title":"Transformer multiflow hottest-spot rating: proposed standard specification","display_name":"Transformer multiflow hottest-spot rating: proposed standard specification","alternate_titles":[],"publication_year":1974,"publication_date":"1974-01-01","ids":{"openalex":"https://openalex.org/W2034492151","doi":"https://doi.org/10.1049/piee.1974.0193","mag":"2034492151"},"language":"en","primary_location":{"id":"doi:10.1049/piee.1974.0193","doi":"https://doi.org/10.1049/piee.1974.0193","is_oa":false,"landing_page_url":"https://doi.org/10.1049/piee.1974.0193","pdf_url":null,"source":{"id":"https://openalex.org/S4210235475","display_name":"Proceedings of the Institution of Electrical Engineers","issn_l":"0020-3270","issn":["0020-3270","2053-7891"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4320800662","host_organization_name":"Institution of Electrical Engineers","host_organization_lineage":["https://openalex.org/P4320800662"],"host_organization_lineage_names":["Institution of Electrical Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the Institution of Electrical Engineers","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W2034492151"],"child_works_count":0,"pull_notice_works":[],"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5059645520","display_name":"E.T. Norris","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"E.T. Norris","raw_affiliation_strings":[", Hunstanton, UK"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":", Hunstanton, UK","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5059645520"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.5903,"has_fulltext":false,"cited_by_count":5,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.62031654,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":92},"biblio":{"volume":"121","issue":"8","first_page":"840","last_page":"840"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.9818999767303467,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.9818999767303467,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12804","display_name":"Thermal Analysis in Power Transmission","score":0.013100000098347664,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11222","display_name":"Magnetic Properties and Applications","score":0.0008999999845400453,"subfield":{"id":"https://openalex.org/subfields/2504","display_name":"Electronic, Optical and Magnetic Materials"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hot-spot-temperature","display_name":"hot spot temperature","score":0.9890000224113464},{"id":"https://openalex.org/keywords/temperature-rise-test","display_name":"temperature rise test","score":0.8069999814033508},{"id":"https://openalex.org/keywords/passive-cooling","display_name":"passive cooling","score":0.9359999895095825},{"id":"https://openalex.org/keywords/directed-flow","display_name":"directed flow","score":0.6439999938011169},{"id":"https://openalex.org/keywords/distribution-transformers","display_name":"distribution transformers","score":0.781000018119812}],"concepts":[{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.5979268550872803},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2899411618709564},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.26747822761535645},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1049/piee.1974.0193","doi":"https://doi.org/10.1049/piee.1974.0193","is_oa":false,"landing_page_url":"https://doi.org/10.1049/piee.1974.0193","pdf_url":null,"source":{"id":"https://openalex.org/S4210235475","display_name":"Proceedings of the Institution of Electrical Engineers","issn_l":"0020-3270","issn":["0020-3270","2053-7891"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4320800662","host_organization_name":"Institution of Electrical Engineers","host_organization_lineage":["https://openalex.org/P4320800662"],"host_organization_lineage_names":["Institution of Electrical Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the Institution of Electrical Engineers","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.878000020980835,"id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W1989393055","https://openalex.org/W2002780561","https://openalex.org/W2045467474","https://openalex.org/W2088879462"],"related_works":["https://openalex.org/W2024990079","https://openalex.org/W2045467474","https://openalex.org/W4252945042","https://openalex.org/W2088879462","https://openalex.org/W4244248203","https://openalex.org/W2084627208","https://openalex.org/W4394019406","https://openalex.org/W7063158752","https://openalex.org/W2044423143","https://openalex.org/W4280623898"],"abstract_inverted_index":{"The":[0,46,98,134,161],"present":[1,61,150,172],"practice":[2],"in":[3,35],"thermal":[4,187],"rating":[5,27,73,137,154,164,174,206],"is":[6,20,67,81,105,208],"reviewed":[7],"with":[8,28,176],"recognition":[9,101],"of":[10,15,102,148,180,189,194,216,234],"its":[11,21],"defects":[12],"and":[13,111,116,129,142,158,192],"limitations,":[14],"which":[16],"the":[17,25,29,38,50,60,92,149,171,177,181,186,190,195,204,219,227,231],"most":[18],"serious":[19],"inability":[22],"to":[23,52,84,144,203,218,226],"relate":[24],"standard":[26,62,72,153,173],"hottest-spot":[30,182],"temperature":[31,183],"(h.s.t.).":[32],"Modern":[33],"improvements":[34],"cooling":[36],"reduce":[37],"h.s.t.,":[39],"but":[40,175,207,229],"are":[41,114,127,132],"circumscribed":[42],"by":[43],"these":[44,140],"limitations.":[45],"multiflow":[47,136],"principle":[48],"allows":[49],"h.s.t.":[51,135],"be":[53,119,166],"determined":[54,167],"for":[55,74,155,211],"each":[56],"individual":[57],"winding":[58],"from":[59],"temperature-rise":[63],"test":[64],"measurements.":[65],"It":[66,80],"anomalous":[68],"that":[69,91],"forced-oil":[70],"cooling\u2014a":[71],"many":[75],"years-has":[76],"never":[77],"been":[78],"defined.":[79],"quite":[82],"legitimate":[83],"install":[85],"such":[86],"a":[87,145],"small":[88,124],"oil":[89],"pump":[90],"term":[93],"has":[94],"no":[95],"real":[96],"significance.":[97],"proposed":[99,162],"international":[100],"directed":[103,112],"flow":[104,113],"neither":[106],"justified":[107],"nor":[108],"desirable.":[109],"Increased":[110],"alternatives,":[115],"must":[117],"both":[118,156],"recognised.":[120],"In":[121],"natural":[122,157],"cooling,":[123],"distribution":[125],"transformers":[126],"underrated":[128],"large":[130],"ones":[131],"overrated.":[133],"removes":[138],"all":[139],"anomalies,":[141],"leads":[143],"draft":[146],"revision":[147],"UK":[151],"national":[152],"forced":[159],"cooling.":[160],"new":[163],"can":[165],"as":[168,170],"simply":[169],"full":[178],"benefit":[179,199],"limit":[184],"controlling":[185],"life":[188],"insulation,":[191],"hence":[193],"transformer":[196],"itself.":[197],"This":[198],"applies":[200],"not":[201],"only":[202],"guaranteed":[205],"available":[209],"also":[210],"other":[212],"service":[213],"loading":[214],"conditions":[215],"concern":[217],"user.":[220],"These":[221],"sometimes":[222],"bear":[223],"little":[224],"relation":[225],"standard,":[228],"widen":[230],"practical":[232],"field":[233],"application":[235]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W2034492151","counts_by_year":[{"year":2017,"cited_by_count":1}],"updated_date":"2026-11-21T10:27:49.728292","created_date":"2016-06-24T00:00:00"}
