{"id":"https://openalex.org/W2031908883","doi":"https://doi.org/10.1109/iecon.2013.6700454","title":"A multivariable nonlinear MPC control strategy for thermal comfort and indoor-air quality","display_name":"A multivariable nonlinear MPC control strategy for thermal comfort and indoor-air quality","publication_year":2013,"publication_date":"2013-11-01","ids":{"openalex":"https://openalex.org/W2031908883","doi":"https://doi.org/10.1109/iecon.2013.6700454","mag":"2031908883"},"language":"en","primary_location":{"id":"doi:10.1109/iecon.2013.6700454","doi":"https://doi.org/10.1109/iecon.2013.6700454","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2013.6700454","pdf_url":null,"source":{"id":"https://openalex.org/S4210172894","display_name":"Annual Conference of the IEEE Industrial Electronics Society (IECON)","issn_l":"1553-572X","issn":["1553-572X","2577-1647"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["jufo-1","norway-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"},"parent_works":[],"lineage":["https://openalex.org/W2031908883"],"child_works_count":0,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5020409352","display_name":"M. Castilla","orcid":"https://orcid.org/0000-0003-4073-7800","observed_orcids":["https://orcid.org/0000-0003-4073-7800"]},"institutions":[{"id":"https://openalex.org/I52354020","display_name":"University of Almer\u00eda","ror":"https://ror.org/003d3xx08","country_code":"ES","type":"education","lineage":["https://openalex.org/I52354020"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Maria del Mar Castilla","raw_affiliation_strings":["(ceiA3) Automatic Control, Electronics and Robotics Research Group, Almer\u00eda, Spain","Autom. Control, Electron. & Robot. Res. Group, Univ. of Almeria, Almeria, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"(ceiA3) Automatic Control, Electronics and Robotics Research Group, Almer\u00eda, Spain","institution_ids":["https://openalex.org/I52354020"]},{"raw_affiliation_string":"Autom. Control, Electron. & Robot. Res. Group, Univ. of Almeria, Almeria, Spain","institution_ids":["https://openalex.org/I52354020"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5065457930","display_name":"J.D. \u00c1lvarez","orcid":"https://orcid.org/0000-0003-2791-8105","observed_orcids":["https://orcid.org/0000-0003-2791-8105"]},"institutions":[{"id":"https://openalex.org/I52354020","display_name":"University of Almer\u00eda","ror":"https://ror.org/003d3xx08","country_code":"ES","type":"education","lineage":["https://openalex.org/I52354020"]},{"id":"https://openalex.org/I79238269","display_name":"Universidad de Sevilla","ror":"https://ror.org/03yxnpp24","country_code":"ES","type":"education","lineage":["https://openalex.org/I79238269"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Jose D. Alvarez","raw_affiliation_strings":["(ceiA3) Automatic Control, Electronics and Robotics Research Group, Almer\u00eda, Spain","Department of Automation and Systems Engineering, University of Seville, Seville, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"(ceiA3) Automatic Control, Electronics and Robotics Research Group, Almer\u00eda, Spain","institution_ids":["https://openalex.org/I52354020"]},{"raw_affiliation_string":"Department of Automation and Systems Engineering, University of Seville, Seville, Spain","institution_ids":["https://openalex.org/I79238269"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5012728420","display_name":"Julio E. Normey\u2010Rico","orcid":"https://orcid.org/0000-0002-6510-9803","observed_orcids":["https://orcid.org/0000-0002-6510-9803"]},"institutions":[{"id":"https://openalex.org/I4104125","display_name":"Universidade Federal de Santa Catarina","ror":"https://ror.org/041akq887","country_code":"BR","type":"education","lineage":["https://openalex.org/I4104125"]},{"id":"https://openalex.org/I52354020","display_name":"University of Almer\u00eda","ror":"https://ror.org/003d3xx08","country_code":"ES","type":"education","lineage":["https://openalex.org/I52354020"]}],"countries":["BR","ES"],"is_corresponding":false,"raw_author_name":"Julio E. Normey-Rico","raw_affiliation_strings":["(ceiA3) Automatic Control, Electronics and Robotics Research Group, Almer\u00eda, Spain","Dept. of Autom. & Syst., Fed. Univ. of Santa Catarina., Florianopolis, Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"(ceiA3) Automatic Control, Electronics and Robotics Research Group, Almer\u00eda, Spain","institution_ids":["https://openalex.org/I52354020"]},{"raw_affiliation_string":"Dept. of Autom. & Syst., Fed. Univ. of Santa Catarina., Florianopolis, Brazil","institution_ids":["https://openalex.org/I4104125"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100447845","display_name":"Francisco Rodr\u00edguez","orcid":"https://orcid.org/0000-0001-9536-1922","observed_orcids":["https://orcid.org/0000-0001-9536-1922"]},"institutions":[{"id":"https://openalex.org/I52354020","display_name":"University of Almer\u00eda","ror":"https://ror.org/003d3xx08","country_code":"ES","type":"education","lineage":["https://openalex.org/I52354020"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Francisco Rodriguez","raw_affiliation_strings":["(ceiA3) Automatic Control, Electronics and Robotics Research Group, Almer\u00eda, Spain","Autom. Control, Electron. & Robot. Res. Group, Univ. of Almeria, Almeria, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"(ceiA3) Automatic Control, Electronics and Robotics Research Group, Almer\u00eda, Spain","institution_ids":["https://openalex.org/I52354020"]},{"raw_affiliation_string":"Autom. Control, Electron. & Robot. Res. Group, Univ. of Almeria, Almeria, Spain","institution_ids":["https://openalex.org/I52354020"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5069378726","display_name":"Manuel Berenguel","orcid":"https://orcid.org/0000-0002-3349-7506","observed_orcids":["https://orcid.org/0000-0002-3349-7506"]},"institutions":[{"id":"https://openalex.org/I52354020","display_name":"University of Almer\u00eda","ror":"https://ror.org/003d3xx08","country_code":"ES","type":"education","lineage":["https://openalex.org/I52354020"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Manuel Berenguel","raw_affiliation_strings":["(ceiA3) Automatic Control, Electronics and Robotics Research Group, Almer\u00eda, Spain","Autom. Control, Electron. & Robot. Res. Group, Univ. of Almeria, Almeria, Spain"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"(ceiA3) Automatic Control, Electronics and Robotics Research Group, Almer\u00eda, Spain","institution_ids":["https://openalex.org/I52354020"]},{"raw_affiliation_string":"Autom. Control, Electron. & Robot. Res. Group, Univ. of Almeria, Almeria, Spain","institution_ids":["https://openalex.org/I52354020"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":2.4886,"has_fulltext":false,"cited_by_count":25,"citation_normalized_percentile":{"value":0.86261412,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"7908","last_page":"7913"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9976000189781189,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9976000189781189,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10791","display_name":"Advanced Control Systems Optimization","score":0.00139999995008111,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11185","display_name":"Integrated Energy Systems Optimization","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/nonlinear-model-predictive-control","display_name":"nonlinear model predictive control","score":0.8429999947547913},{"id":"https://openalex.org/keywords/multivariable-control","display_name":"multivariable control","score":0.9430000185966492},{"id":"https://openalex.org/keywords/thermal-comfort","display_name":"thermal comfort","score":0.9940000176429749},{"id":"https://openalex.org/keywords/indoor-air-quality","display_name":"indoor air quality","score":0.9919999837875366},{"id":"https://openalex.org/keywords/hvac-systems","display_name":"HVAC systems","score":0.9380000233650208},{"id":"https://openalex.org/keywords/natural-ventilation","display_name":"natural ventilation","score":0.9800000190734863},{"id":"https://openalex.org/keywords/window-ventilation","display_name":"window ventilation","score":0.6869999766349792},{"id":"https://openalex.org/keywords/bioclimatic-buildings","display_name":"bioclimatic buildings","score":0.8370000123977661},{"id":"https://openalex.org/keywords/building-climate-control","display_name":"building climate control","score":0.6460000276565552}],"concepts":[{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.8573524951934814},{"id":"https://openalex.org/C133913538","wikidata":"https://www.wikidata.org/wiki/Q774514","display_name":"Thermal comfort","level":2,"score":0.8509020805358887},{"id":"https://openalex.org/C117312493","wikidata":"https://www.wikidata.org/wiki/Q2035437","display_name":"Multivariable calculus","level":2,"score":0.6729125380516052},{"id":"https://openalex.org/C206018219","wikidata":"https://www.wikidata.org/wiki/Q1427418","display_name":"Natural ventilation","level":3,"score":0.6683496832847595},{"id":"https://openalex.org/C65469","wikidata":"https://www.wikidata.org/wiki/Q905504","display_name":"Indoor air quality","level":2,"score":0.6682727336883545},{"id":"https://openalex.org/C172205157","wikidata":"https://www.wikidata.org/wiki/Q1782962","display_name":"Model predictive control","level":3,"score":0.597423255443573},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.5890885591506958},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.5761847496032715},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.47304171323776245},{"id":"https://openalex.org/C158622935","wikidata":"https://www.wikidata.org/wiki/Q660848","display_name":"Nonlinear system","level":2,"score":0.4555044174194336},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.45077890157699585},{"id":"https://openalex.org/C17005505","wikidata":"https://www.wikidata.org/wiki/Q11164636","display_name":"Energy recovery ventilation","level":4,"score":0.4386581480503082},{"id":"https://openalex.org/C170154142","wikidata":"https://www.wikidata.org/wiki/Q150737","display_name":"Architectural engineering","level":1,"score":0.4182230234146118},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3961026072502136},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.34952017664909363},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.3494744300842285},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3331378698348999},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.33112481236457825},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.11772221326828003},{"id":"https://openalex.org/C87717796","wikidata":"https://www.wikidata.org/wiki/Q146326","display_name":"Environmental engineering","level":1,"score":0.09997987747192383},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0662350058555603},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.061467766761779785},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iecon.2013.6700454","doi":"https://doi.org/10.1109/iecon.2013.6700454","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iecon.2013.6700454","pdf_url":null,"source":{"id":"https://openalex.org/S4210172894","display_name":"Annual Conference of the IEEE Industrial Electronics Society (IECON)","issn_l":"1553-572X","issn":["1553-572X","2577-1647"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["jufo-1","norway-1"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320322025","display_name":"Conselho Nacional de Desenvolvimento Cient\u00edfico e Tecnol\u00f3gico","ror":"https://ror.org/03swz6y49"},{"id":"https://openalex.org/F4320331435","display_name":"Universidad de Almer\u00eda","ror":"https://ror.org/003d3xx08"},{"id":"https://openalex.org/F4320335322","display_name":"European Regional Development Fund","ror":"https://ror.org/00k4n6c32"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W46883718","https://openalex.org/W292508636","https://openalex.org/W1569112067","https://openalex.org/W2003981033","https://openalex.org/W2006732032","https://openalex.org/W2016660644","https://openalex.org/W2017449880","https://openalex.org/W2033200113","https://openalex.org/W2104325473","https://openalex.org/W4246511113"],"related_works":["https://openalex.org/W2148080268","https://openalex.org/W4400189465","https://openalex.org/W4384833652","https://openalex.org/W2027700507","https://openalex.org/W2038757772","https://openalex.org/W2953408255","https://openalex.org/W4414301613","https://openalex.org/W1521120104","https://openalex.org/W2989651212","https://openalex.org/W2095492387"],"abstract_inverted_index":{"Comfort":[0],"conditions":[1],"inside":[2,38],"buildings":[3],"are":[4,117],"a":[5,15,39,47,73,110,114],"problem":[6],"that":[7],"is":[8,43],"being":[9],"widely":[10,120],"analyzed,":[11],"since":[12],"it":[13,42],"has":[14],"direct":[16],"effect":[17,24],"on":[18,25],"users'":[19],"productivity,":[20],"and":[21,35,53,61,65,85,92,119],"an":[22],"indirect":[23],"energy":[26],"saving.":[27],"Hence,":[28],"in":[29,109],"order":[30,96],"to":[31,45,80,97],"maintain":[32,82],"thermal":[33,83],"comfort":[34,84],"indoor-air":[36,86],"quality":[37,87],"certain":[40],"environment,":[41],"required":[44],"perform":[46],"proper":[48],"management":[49],"of":[50,90,101,113],"its":[51],"active":[52],"passive":[54],"components,":[55],"as":[56],"the":[57,99,102],"HVAC":[58],"(Heating,":[59],"Ventilation":[60],"Air":[62],"Conditioning)":[63],"systems,":[64],"natural":[66,93],"ventilation":[67],"through":[68],"windows.":[69],"This":[70],"paper":[71],"presents":[72],"multivariable":[74],"nonlinear":[75],"model":[76],"predictive":[77],"control":[78,104],"system":[79],"simultaneously":[81],"by":[88],"means":[89],"forced":[91],"ventilation.":[94],"In":[95],"probe":[98],"effectiveness":[100],"proposed":[103],"approach,":[105],"simulation":[106],"results":[107],"obtained":[108],"characteristic":[111],"room":[112],"bioclimatic":[115],"building":[116],"included":[118],"commented.":[121]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2023,"cited_by_count":3},{"year":2022,"cited_by_count":4},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":4},{"year":2018,"cited_by_count":3},{"year":2017,"cited_by_count":3},{"year":2016,"cited_by_count":1},{"year":2014,"cited_by_count":2}],"updated_date":"2026-11-10T11:39:43.021295","created_date":"2016-06-24T00:00:00"}
