{"id":"https://openalex.org/W2024679974","doi":"https://doi.org/10.1007/s10891-010-0290-x","title":"Influence of the rates of gas flows through the smoke-removal and input-ventilation systems on the height of the smoke-free zone in a fire within a building","display_name":"Influence of the rates of gas flows through the smoke-removal and input-ventilation systems on the height of the smoke-free zone in a fire within a building","publication_year":2009,"publication_date":"2009-11-01","ids":{"openalex":"https://openalex.org/W2024679974","doi":"https://doi.org/10.1007/s10891-010-0290-x","mag":"2024679974"},"language":"en","primary_location":{"id":"doi:10.1007/s10891-010-0290-x","doi":"https://doi.org/10.1007/s10891-010-0290-x","is_oa":false,"landing_page_url":"https://doi.org/10.1007/s10891-010-0290-x","pdf_url":null,"source":{"id":"https://openalex.org/S4210193849","display_name":"Journal of Engineering Physics and Thermophysics","issn_l":"1062-0125","issn":["1062-0125","1573-871X"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["dongbi-c","jufo-1","norway-1","poland-70","russia-white-list-3"],"host_organization":"https://openalex.org/P4310319900","host_organization_name":"Springer Science+Business Media","host_organization_lineage":["https://openalex.org/P4310319900","https://openalex.org/P4310319965"],"host_organization_lineage_names":["Springer Science+Business Media","Springer Nature"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Engineering Physics and Thermophysics","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5091246904","display_name":"\u0421. \u0412. \u041f\u0443\u0437\u0430\u0447","orcid":"https://orcid.org/0000-0001-7234-1339","observed_orcids":["https://orcid.org/0000-0001-7234-1339"]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"S. V. Puzach","raw_affiliation_strings":["Academy of State Fire-Prevention Service, Ministry of Extraordinary Situations, 4 B. Golushkin Str., Moscow, 129366, Russia","Academy of State Fire-Prevention Service, Ministry of Extraordinary Situations"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Academy of State Fire-Prevention Service, Ministry of Extraordinary Situations, 4 B. Golushkin Str., Moscow, 129366, Russia","institution_ids":[]},{"raw_affiliation_string":"Academy of State Fire-Prevention Service, Ministry of Extraordinary Situations","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5019851789","display_name":"Nguy\u1ec5n Thanh H\u1ea3i","orcid":"https://orcid.org/0000-0001-7601-9515","observed_orcids":["https://orcid.org/0000-0001-7601-9515"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Nguyen Thanh Hai","raw_affiliation_strings":["Academy of State Fire-Prevention Service, Ministry of Extraordinary Situations, 4 B. Golushkin Str., Moscow, 129366, Russia","Academy of State Fire-Prevention Service, Ministry of Extraordinary Situations"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Academy of State Fire-Prevention Service, Ministry of Extraordinary Situations, 4 B. Golushkin Str., Moscow, 129366, Russia","institution_ids":[]},{"raw_affiliation_string":"Academy of State Fire-Prevention Service, Ministry of Extraordinary Situations","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5091246904"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.25871602,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":93},"biblio":{"volume":"82","issue":"6","first_page":"1033","last_page":"1041"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11317","display_name":"Fire dynamics and safety research","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11317","display_name":"Fire dynamics and safety research","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11371","display_name":"Wind and Air Flow Studies","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2305","display_name":"Environmental Engineering"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12597","display_name":"Fire Detection and Safety Systems","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/structure-fires","display_name":"building fires","score":0.5080000162124634},{"id":"https://openalex.org/keywords/smoke-movement","display_name":"smoke spread","score":0.37700000405311584},{"id":"https://openalex.org/keywords/cold-air-supply","display_name":"cold air supply","score":0.722000002861023},{"id":"https://openalex.org/keywords/gas-flow-rate","display_name":"gas flow rate","score":0.6200000047683716},{"id":"https://openalex.org/keywords/point-heat-source","display_name":"point heat source","score":0.7509999871253967},{"id":"https://openalex.org/keywords/entrainment","display_name":"entrainment","score":0.527999997138977},{"id":"https://openalex.org/keywords/integral-model","display_name":"integral model","score":0.5899999737739563},{"id":"https://openalex.org/keywords/zonal-model","display_name":"zonal model","score":0.8759999871253967},{"id":"https://openalex.org/keywords/empirical-model","display_name":"empirical model","score":0.39500001072883606}],"concepts":[{"id":"https://openalex.org/C58874564","wikidata":"https://www.wikidata.org/wiki/Q130768","display_name":"Smoke","level":2,"score":0.892734944820404},{"id":"https://openalex.org/C2777489069","wikidata":"https://www.wikidata.org/wiki/Q1589822","display_name":"Ceiling (cloud)","level":2,"score":0.818810760974884},{"id":"https://openalex.org/C105923489","wikidata":"https://www.wikidata.org/wiki/Q133235","display_name":"Combustion","level":2,"score":0.6827960014343262},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.610917329788208},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.5751401782035828},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.5330216884613037},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.500791072845459},{"id":"https://openalex.org/C38349280","wikidata":"https://www.wikidata.org/wiki/Q1434290","display_name":"Flow (mathematics)","level":2,"score":0.45393598079681396},{"id":"https://openalex.org/C111603439","wikidata":"https://www.wikidata.org/wiki/Q752193","display_name":"Boundary layer","level":2,"score":0.44754213094711304},{"id":"https://openalex.org/C91586092","wikidata":"https://www.wikidata.org/wiki/Q757520","display_name":"Atmospheric sciences","level":1,"score":0.325588196516037},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.2708083689212799},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.1926557421684265},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.07331609725952148},{"id":"https://openalex.org/C178790620","wikidata":"https://www.wikidata.org/wiki/Q11351","display_name":"Organic chemistry","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1007/s10891-010-0290-x","doi":"https://doi.org/10.1007/s10891-010-0290-x","is_oa":false,"landing_page_url":"https://doi.org/10.1007/s10891-010-0290-x","pdf_url":null,"source":{"id":"https://openalex.org/S4210193849","display_name":"Journal of Engineering Physics and Thermophysics","issn_l":"1062-0125","issn":["1062-0125","1573-871X"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["dongbi-c","jufo-1","norway-1","poland-70","russia-white-list-3"],"host_organization":"https://openalex.org/P4310319900","host_organization_name":"Springer Science+Business Media","host_organization_lineage":["https://openalex.org/P4310319900","https://openalex.org/P4310319965"],"host_organization_lineage_names":["Springer Science+Business Media","Springer Nature"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Engineering Physics and Thermophysics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W2006214259","https://openalex.org/W2042419012","https://openalex.org/W2318107479","https://openalex.org/W2492693241","https://openalex.org/W6606377054"],"related_works":["https://openalex.org/W2955153200","https://openalex.org/W2037980873","https://openalex.org/W2023999085","https://openalex.org/W2581002449","https://openalex.org/W2137815438","https://openalex.org/W639241294","https://openalex.org/W2053755869","https://openalex.org/W1971482946","https://openalex.org/W2370810905","https://openalex.org/W2604649316"],"abstract_inverted_index":null,"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2020,"cited_by_count":1}],"updated_date":"2026-06-19T15:47:20.252518","created_date":"2016-06-24T00:00:00"}