{"id":"https://openalex.org/W2020649462","doi":"https://doi.org/10.1109/ppic.2013.6656057","title":"Reliability Centered Maintenance for electrical equipment critical to worker safety","display_name":"Reliability Centered Maintenance for electrical equipment critical to worker safety","publication_year":2013,"publication_date":"2013-06-01","ids":{"openalex":"https://openalex.org/W2020649462","doi":"https://doi.org/10.1109/ppic.2013.6656057","mag":"2020649462"},"language":"en","primary_location":{"id":"doi:10.1109/ppic.2013.6656057","doi":"https://doi.org/10.1109/ppic.2013.6656057","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ppic.2013.6656057","pdf_url":null,"source":{"id":"https://openalex.org/S4210177915","display_name":"IEEE Conference record of annual Pulp and Paper Industry Technical Conference","issn_l":"0190-2172","issn":["0190-2172"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Conference Record of 2013 Annual IEEE Pulp and Paper Industry Technical Conference (PPIC)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5041451343","display_name":"John C. Webb","orcid":"https://orcid.org/0000-0003-4347-0304","observed_orcids":["https://orcid.org/0000-0003-4347-0304"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"John C. Webb","raw_affiliation_strings":["Medium Voltage Service, ABB Inc., Florence, SC, USA","ABB Inc., Florence, SC, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Medium Voltage Service, ABB Inc., Florence, SC, USA","institution_ids":[]},{"raw_affiliation_string":"ABB Inc., Florence, SC, USA","institution_ids":[]}]},{"author_position":"middle","author":{"id":null,"display_name":"Michael D. Fontaine","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I48798816","display_name":"National Fire Protection Association","ror":"https://ror.org/01zc8t088","country_code":"US","type":"nonprofit","lineage":["https://openalex.org/I48798816"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Michael D. Fontaine","raw_affiliation_strings":["Liaison for NFPA 70E. IEEE, National Fire Protection Association, Quincy, MA, USA","[National Fire Protection Association, Quincy, MA, USA]"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Liaison for NFPA 70E. IEEE, National Fire Protection Association, Quincy, MA, USA","institution_ids":["https://openalex.org/I48798816"]},{"raw_affiliation_string":"[National Fire Protection Association, Quincy, MA, USA]","institution_ids":["https://openalex.org/I48798816"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5091195861","display_name":"Dennis M. Green","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I1297132110","display_name":"Los Angeles Police Department","ror":"https://ror.org/03c71f034","country_code":"US","type":"government","lineage":["https://openalex.org/I1297132110"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Dennis M. Green","raw_affiliation_strings":["Tony Demaria Electric, Los Angeles, CA, USA","Tony Demaria Electr., Los Angeles, CA, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Tony Demaria Electric, Los Angeles, CA, USA","institution_ids":["https://openalex.org/I1297132110"]},{"raw_affiliation_string":"Tony Demaria Electr., Los Angeles, CA, USA","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5049852628","display_name":"Peter A. Stoppello","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Peter A. Stoppello","raw_affiliation_strings":["[ANSI Service Products, ABB, Inc., Napa, CA, USA]"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"[ANSI Service Products, ABB, Inc., Napa, CA, USA]","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.9173,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.63236089,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":93},"biblio":{"volume":null,"issue":null,"first_page":"157","last_page":"164"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.9115999937057495,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.9115999937057495,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.06509999930858612,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.015399999916553497,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/reliability-centered-maintenance","display_name":"reliability-centered maintenance","score":0.9580000042915344},{"id":"https://openalex.org/keywords/electrical-safety","display_name":"electrical safety","score":0.9750000238418579},{"id":"https://openalex.org/keywords/arc-flash-hazard-analysis","display_name":"arc flash hazard analysis","score":0.9139999747276306},{"id":"https://openalex.org/keywords/maintenance-conditions","display_name":"maintenance conditions","score":0.5820000171661377},{"id":"https://openalex.org/keywords/condition-monitoring","display_name":"condition monitoring","score":0.8109999895095825},{"id":"https://openalex.org/keywords/nfpa-70e","display_name":"NFPA 70E","score":0.9039999842643738},{"id":"https://openalex.org/keywords/occupational-safety","display_name":"occupational safety","score":0.9039999842643738},{"id":"https://openalex.org/keywords/electrical-equipment-reliability","display_name":"electrical equipment reliability","score":0.7900000214576721}],"concepts":[{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.7221752405166626},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.7059109210968018},{"id":"https://openalex.org/C23725684","wikidata":"https://www.wikidata.org/wiki/Q616377","display_name":"Maintenance engineering","level":2,"score":0.4581126570701599},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.45704182982444763},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3130742907524109},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.12556570768356323},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ppic.2013.6656057","doi":"https://doi.org/10.1109/ppic.2013.6656057","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ppic.2013.6656057","pdf_url":null,"source":{"id":"https://openalex.org/S4210177915","display_name":"IEEE Conference record of annual Pulp and Paper Industry Technical Conference","issn_l":"0190-2172","issn":["0190-2172"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Conference Record of 2013 Annual IEEE Pulp and Paper Industry Technical Conference (PPIC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":8,"referenced_works":["https://openalex.org/W1487969161","https://openalex.org/W2030143855","https://openalex.org/W4241253464","https://openalex.org/W4244121547","https://openalex.org/W4245679861","https://openalex.org/W4251366649","https://openalex.org/W4256489157","https://openalex.org/W4289672141"],"related_works":["https://openalex.org/W2028427243","https://openalex.org/W2392065012","https://openalex.org/W7204834366","https://openalex.org/W2361346454","https://openalex.org/W2153520783","https://openalex.org/W2073037803","https://openalex.org/W91262664","https://openalex.org/W2608844062","https://openalex.org/W200193148","https://openalex.org/W2389798429"],"abstract_inverted_index":{"This":[0,49,62],"paper":[1,63],"explores":[2],"Reliability":[3],"Centered":[4],"Maintenance":[5],"(RCM)":[6],"and":[7,40,66,77,91,93],"Electrical":[8,17],"Safety.":[9],"Section":[10],"130.5":[11],"of":[12,35,47,53,86],"NFPA":[13],"70E\u00ae":[14],"Standard":[15],"for":[16],"Safety":[18],"in":[19,60,103],"the":[20,33,36,84,104],"Workplace":[21],"states":[22],"that":[23],"\u201cthe":[24,54],"arc":[25],"flash":[26],"hazard":[27],"analysis":[28],"shall":[29],"take":[30],"into":[31],"consideration":[32],"design":[34],"overcurrent":[37],"protection":[38],"device":[39],"its":[41,45],"opening":[42],"time,":[43],"including":[44],"condition":[46],"maintenance\u201d.":[48],"very":[50],"important":[51],"concept":[52],"maintenance":[55],"condition\u201d":[56],"can":[57],"be":[58,71],"found":[59],"RCM.":[61],"will":[64,80],"review":[65],"explore":[67],"how":[68,92],"RCM":[69],"may":[70],"used":[72],"to":[73,95,99],"improve":[74,100],"electrical":[75,101],"safety":[76,102],"reliability.":[78],"We":[79],"also":[81],"look":[82],"at":[83],"use":[85],"Condition":[87],"Based":[88],"Monitoring":[89],"(CBM)":[90],"when":[94],"apply":[96],"this":[97],"approach":[98],"workplace.":[105]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2014,"cited_by_count":1}],"updated_date":"2026-11-10T11:39:43.021295","created_date":"2016-06-24T00:00:00"}
