{"id":"https://openalex.org/W2020395813","doi":"https://doi.org/10.1016/j.egypro.2014.03.038","title":"Thermal Stresses Analysis of a Circular Tube in a Central Receiver","display_name":"Thermal Stresses Analysis of a Circular Tube in a Central Receiver","publication_year":2014,"publication_date":"2014-01-01","ids":{"openalex":"https://openalex.org/W2020395813","doi":"https://doi.org/10.1016/j.egypro.2014.03.038","mag":"2020395813"},"language":"en","primary_location":{"id":"doi:10.1016/j.egypro.2014.03.038","doi":"https://doi.org/10.1016/j.egypro.2014.03.038","is_oa":true,"landing_page_url":"https://doi.org/10.1016/j.egypro.2014.03.038","pdf_url":null,"source":{"id":"https://openalex.org/S75069817","display_name":"Energy Procedia","issn_l":"1876-6102","issn":["1876-6102"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","jufo-1"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energy Procedia","raw_type":"journal-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"https://doi.org/10.1016/j.egypro.2014.03.038","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5034669740","display_name":"\u00d3scar Flores","orcid":"https://orcid.org/0000-0003-2365-0738","observed_orcids":["https://orcid.org/0000-0003-2365-0738"]},"institutions":[{"id":"https://openalex.org/I50357001","display_name":"Universidad Carlos III de Madrid","ror":"https://ror.org/03ths8210","country_code":"ES","type":"education","lineage":["https://openalex.org/I50357001"]}],"countries":["ES"],"is_corresponding":true,"raw_author_name":"O. Flores","raw_affiliation_strings":["Department of Bioengineering and Aerospace, Universidad Carlos III de Madrid"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Bioengineering and Aerospace, Universidad Carlos III de Madrid","institution_ids":["https://openalex.org/I50357001"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5061064536","display_name":"C. Marug\u00e1n-Cruz","orcid":"https://orcid.org/0000-0002-1288-1963","observed_orcids":["https://orcid.org/0000-0002-1288-1963"]},"institutions":[{"id":"https://openalex.org/I50357001","display_name":"Universidad Carlos III de Madrid","ror":"https://ror.org/03ths8210","country_code":"ES","type":"education","lineage":["https://openalex.org/I50357001"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"C. Marug\u00e1n-Cruz","raw_affiliation_strings":["Department of Fluids and Thermal Engineering, Universidad Carlos III de Madrid, Avda Universidad 30, Legan\u00e9s, 28911. Madrid (Spain)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Fluids and Thermal Engineering, Universidad Carlos III de Madrid, Avda Universidad 30, Legan\u00e9s, 28911. Madrid (Spain)","institution_ids":["https://openalex.org/I50357001"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5020747952","display_name":"Domingo Santana","orcid":"https://orcid.org/0000-0002-2171-1763","observed_orcids":["https://orcid.org/0000-0002-2171-1763"]},"institutions":[{"id":"https://openalex.org/I50357001","display_name":"Universidad Carlos III de Madrid","ror":"https://ror.org/03ths8210","country_code":"ES","type":"education","lineage":["https://openalex.org/I50357001"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"D. Santana","raw_affiliation_strings":["Department of Fluids and Thermal Engineering, Universidad Carlos III de Madrid, Avda Universidad 30, Legan\u00e9s, 28911. Madrid (Spain)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Fluids and Thermal Engineering, Universidad Carlos III de Madrid, Avda Universidad 30, Legan\u00e9s, 28911. Madrid (Spain)","institution_ids":["https://openalex.org/I50357001"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5053295248","display_name":"Manuel Garc\u00eda\u2010Villalba","orcid":"https://orcid.org/0000-0002-6953-2270","observed_orcids":["https://orcid.org/0000-0002-6953-2270"]},"institutions":[{"id":"https://openalex.org/I50357001","display_name":"Universidad Carlos III de Madrid","ror":"https://ror.org/03ths8210","country_code":"ES","type":"education","lineage":["https://openalex.org/I50357001"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"M. Garc\u00eda-Villalba","raw_affiliation_strings":["Department of Bioengineering and Aerospace, Universidad Carlos III de Madrid"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Bioengineering and Aerospace, Universidad Carlos III de Madrid","institution_ids":["https://openalex.org/I50357001"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5034669740"],"corresponding_institution_ids":["https://openalex.org/I50357001"],"apc_list":null,"apc_paid":null,"fwci":4.8978,"has_fulltext":false,"cited_by_count":29,"citation_normalized_percentile":{"value":0.95302013,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":88,"max":98},"biblio":{"volume":"49","issue":null,"first_page":"354","last_page":"362"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10905","display_name":"Solar Thermal and Photovoltaic Systems","score":0.9750999808311462,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10905","display_name":"Solar Thermal and Photovoltaic Systems","score":0.9750999808311462,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10938","display_name":"Phase Change Materials Research","score":0.0034000000450760126,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11802","display_name":"Chemical Looping and Thermochemical Processes","score":0.002400000113993883,"subfield":{"id":"https://openalex.org/subfields/2103","display_name":"Fuel Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/thermal-stress","display_name":"thermal stress","score":0.9110000133514404},{"id":"https://openalex.org/keywords/circular-tube","display_name":"circular tube","score":0.5059999823570251},{"id":"https://openalex.org/keywords/concentrated-solar-power","display_name":"concentrated solar power","score":0.9150000214576721},{"id":"https://openalex.org/keywords/316l-stainless-steel","display_name":"316L stainless steel","score":0.9819999933242798},{"id":"https://openalex.org/keywords/temperature-distribution","display_name":"temperature distribution","score":0.6100000143051147},{"id":"https://openalex.org/keywords/tube-diameter","display_name":"tube diameter","score":0.6290000081062317},{"id":"https://openalex.org/keywords/wall-thickness","display_name":"wall thickness","score":0.984000027179718},{"id":"https://openalex.org/keywords/von-mises-stress","display_name":"von Mises stress","score":0.8320000171661377},{"id":"https://openalex.org/keywords/convection-coefficient","display_name":"convection coefficient","score":0.796999990940094}],"concepts":[{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.7061461210250854},{"id":"https://openalex.org/C2777551473","wikidata":"https://www.wikidata.org/wiki/Q2093072","display_name":"Tube (container)","level":2,"score":0.6614679098129272},{"id":"https://openalex.org/C159188206","wikidata":"https://www.wikidata.org/wiki/Q1478382","display_name":"Heat flux","level":3,"score":0.6542147994041443},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.6335003972053528},{"id":"https://openalex.org/C50517652","wikidata":"https://www.wikidata.org/wiki/Q179635","display_name":"Heat transfer","level":2,"score":0.6116334199905396},{"id":"https://openalex.org/C2779473208","wikidata":"https://www.wikidata.org/wiki/Q285927","display_name":"Concentrated solar power","level":3,"score":0.569636881351471},{"id":"https://openalex.org/C18762648","wikidata":"https://www.wikidata.org/wiki/Q42213","display_name":"Work (physics)","level":2,"score":0.5204399228096008},{"id":"https://openalex.org/C29700514","wikidata":"https://www.wikidata.org/wiki/Q634340","display_name":"Heat transfer coefficient","level":3,"score":0.4784829020500183},{"id":"https://openalex.org/C2779301550","wikidata":"https://www.wikidata.org/wiki/Q217236","display_name":"Working fluid","level":2,"score":0.46319645643234253},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.45287027955055237},{"id":"https://openalex.org/C10899652","wikidata":"https://www.wikidata.org/wiki/Q160329","display_name":"Convection","level":2,"score":0.43321043252944946},{"id":"https://openalex.org/C21036866","wikidata":"https://www.wikidata.org/wiki/Q181767","display_name":"Stress (linguistics)","level":2,"score":0.43261855840682983},{"id":"https://openalex.org/C41231900","wikidata":"https://www.wikidata.org/wiki/Q918227","display_name":"Convective heat transfer","level":3,"score":0.4287654161453247},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.3402699828147888},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.3285145163536072},{"id":"https://openalex.org/C183287310","wikidata":"https://www.wikidata.org/wiki/Q2142963","display_name":"Thermal energy storage","level":2,"score":0.1720428764820099},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.13932648301124573},{"id":"https://openalex.org/C138885662","wikidata":"https://www.wikidata.org/wiki/Q5891","display_name":"Philosophy","level":0,"score":0.0},{"id":"https://openalex.org/C41895202","wikidata":"https://www.wikidata.org/wiki/Q8162","display_name":"Linguistics","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1016/j.egypro.2014.03.038","doi":"https://doi.org/10.1016/j.egypro.2014.03.038","is_oa":true,"landing_page_url":"https://doi.org/10.1016/j.egypro.2014.03.038","pdf_url":null,"source":{"id":"https://openalex.org/S75069817","display_name":"Energy Procedia","issn_l":"1876-6102","issn":["1876-6102"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","jufo-1"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energy Procedia","raw_type":"journal-article"},{"id":"pmh:oai:HAL:hal-05781444v1","doi":null,"is_oa":false,"landing_page_url":"https://hal.science/hal-05781444","pdf_url":null,"source":{"id":"https://openalex.org/S4306402512","display_name":"HAL","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I4405252976","host_organization_name":"Centre pour la Communication Scientifique Directe","host_organization_lineage":["https://openalex.org/I4405252976"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Energy Procedia, 2014, 49, pp.354-362. &#x27E8;10.1016/j.egypro.2014.03.038&#x27E9;","raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":{"id":"doi:10.1016/j.egypro.2014.03.038","doi":"https://doi.org/10.1016/j.egypro.2014.03.038","is_oa":true,"landing_page_url":"https://doi.org/10.1016/j.egypro.2014.03.038","pdf_url":null,"source":{"id":"https://openalex.org/S75069817","display_name":"Energy Procedia","issn_l":"1876-6102","issn":["1876-6102"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","jufo-1"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energy Procedia","raw_type":"journal-article"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.571399986743927,"id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320321043","display_name":"Centro para el Desarrollo Tecnol\u00f3gico Industrial","ror":"https://ror.org/0124x7055"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W43246133","https://openalex.org/W1490180844","https://openalex.org/W1602346051","https://openalex.org/W1969729939","https://openalex.org/W1976051133","https://openalex.org/W1986521793","https://openalex.org/W2011351455","https://openalex.org/W2038576417","https://openalex.org/W2059904818","https://openalex.org/W2067160055","https://openalex.org/W2077036659","https://openalex.org/W2080855009","https://openalex.org/W2188402916","https://openalex.org/W2615797329"],"related_works":["https://openalex.org/W2151472371","https://openalex.org/W3190466014","https://openalex.org/W2780946396","https://openalex.org/W3013990395","https://openalex.org/W7222320000","https://openalex.org/W2368538950","https://openalex.org/W1982118443","https://openalex.org/W6903635675","https://openalex.org/W3200476823","https://openalex.org/W2796552984"],"abstract_inverted_index":{"The":[0],"tubes":[1,160],"of":[2,36,49,57,118,158,176,191],"central":[3],"receiver":[4,194],"power":[5],"plants":[6],"are":[7],"designed":[8],"to":[9,21,114,171],"work":[10,108],"under":[11],"very":[12],"demanding":[13],"conditions,":[14],"with":[15,67],"heat":[16,41,73,138,152],"fluxes":[17],"varying":[18],"between":[19],"0.2":[20],"1":[22],"MW/m":[23],"2":[24],",":[25],"depending":[26],"on":[27,52,92],"both":[28,70],"the":[29,33,37,40,46,50,53,58,72,77,93,103,116,125,129,151,156,159,162,173,177,180,184,187,192],"weather":[30],"conditions":[31],"and":[32,76,96,121,131,143,155,179],"operating":[34],"regime":[35],"plant.":[38],"Also,":[39],"flux":[42,139],"is":[43,83,98],"localized":[44],"along":[45,183],"circumferential":[47],"coordinate":[48],"tube,":[51],"outward":[54],"facing":[55],"side":[56],"tube.":[59],"This":[60],"results":[61],"in":[62,71,124,128,161],"a":[63,99,134],"non-uniform":[64],"temperature":[65,126,174],"distribution":[66,82,175],"strong":[68],"gradients":[69],"transfer":[74,153],"fluid":[75,104,130,154,178],"pipe":[78,94],"walls.":[79],"Predicting":[80],"this":[81,107],"important":[84],"since":[85],"it":[86,97],"can":[87],"induce":[88],"high":[89],"thermal":[90,189],"stresses":[91,190],"walls":[95],"key":[100],"factor":[101],"for":[102,133],"decomposition.":[105],"In":[106],"we":[109],"have":[110,147,195],"studied":[111],"different":[112],"configurations":[113],"analyze":[115],"effects":[117],"tube":[119,193],"diameter":[120],"wall":[122],"thickness":[123],"distributions":[127],"solid,":[132],"typical":[135],"concentrated":[136],"solar":[137],"distribution.":[140],"HITEC":[141],"salt":[142],"316L":[144],"stainless":[145],"steel":[146],"been":[148,169,196],"used":[149,170],"as":[150],"material":[157],"receiver,":[163],"respectively.":[164],"A":[165],"numerical":[166],"method":[167],"has":[168],"calculate":[172],"convection":[181],"coefficient":[182],"circumference.":[185],"Finally":[186],"Von-Mises":[188],"calculated.":[197]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":4},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":4},{"year":2020,"cited_by_count":4},{"year":2019,"cited_by_count":3},{"year":2017,"cited_by_count":4},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":4}],"updated_date":"2026-10-25T09:29:13.331239","created_date":"2016-06-24T00:00:00"}
