{"id":"https://openalex.org/W2019657015","doi":"https://doi.org/10.1179/000705971798324224","title":"Prevention of Corrosion in Domestic Hot Water Central Heating Systems","display_name":"Prevention of Corrosion in Domestic Hot Water Central Heating Systems","publication_year":1971,"publication_date":"1971-01-01","ids":{"openalex":"https://openalex.org/W2019657015","doi":"https://doi.org/10.1179/000705971798324224","mag":"2019657015"},"language":"en","primary_location":{"id":"doi:10.1179/000705971798324224","doi":"https://doi.org/10.1179/000705971798324224","is_oa":false,"landing_page_url":"https://doi.org/10.1179/000705971798324224","pdf_url":null,"source":{"id":"https://openalex.org/S187934678","display_name":"British Corrosion Journal","issn_l":"0007-0599","issn":["0007-0599","2048-2892"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","norway-1"],"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["Taylor & Francis","Informa"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"British Corrosion Journal","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5025070920","display_name":"J. B. Cotton","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"J. B. Cotton","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5078491448","display_name":"Wayne Jacob","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"W. R. Jacob","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":10,"citation_normalized_percentile":{"value":0.25552679,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":92},"biblio":{"volume":"6","issue":"1","first_page":"42","last_page":"44"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10310","display_name":"Corrosion Behavior and Inhibition","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10310","display_name":"Corrosion Behavior and Inhibition","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12086","display_name":"Structural Integrity and Reliability Analysis","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10736","display_name":"Hydrogen embrittlement and corrosion behaviors in metals","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2506","display_name":"Metals and Alloys"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/corrosion-protection","display_name":"corrosion protection","score":0.8679999709129333},{"id":"https://openalex.org/keywords/domestic-hot-water","display_name":"domestic hot water","score":0.6439999938011169},{"id":"https://openalex.org/keywords/central-heating","display_name":"central heating","score":0.9950000047683716},{"id":"https://openalex.org/keywords/corrosion-inhibitors","display_name":"corrosion inhibitors","score":0.7269999980926514},{"id":"https://openalex.org/keywords/air-ingress","display_name":"air ingress","score":0.9430000185966492},{"id":"https://openalex.org/keywords/water-leakage","display_name":"water leakage","score":0.671999990940094},{"id":"https://openalex.org/keywords/remedial-measures","display_name":"remedial measures","score":0.5809999704360962}],"concepts":[{"id":"https://openalex.org/C20625102","wikidata":"https://www.wikidata.org/wiki/Q137056","display_name":"Corrosion","level":2,"score":0.9097489714622498},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.5055217742919922},{"id":"https://openalex.org/C196513747","wikidata":"https://www.wikidata.org/wiki/Q7311595","display_name":"Remedial action","level":4,"score":0.4925890564918518},{"id":"https://openalex.org/C2777781897","wikidata":"https://www.wikidata.org/wiki/Q181395","display_name":"Magnetite","level":2,"score":0.48179930448532104},{"id":"https://openalex.org/C2983288566","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Central air conditioning","level":3,"score":0.4477371275424957},{"id":"https://openalex.org/C2777154459","wikidata":"https://www.wikidata.org/wiki/Q2429341","display_name":"Heating system","level":2,"score":0.43733179569244385},{"id":"https://openalex.org/C191897082","wikidata":"https://www.wikidata.org/wiki/Q11467","display_name":"Metallurgy","level":1,"score":0.437104195356369},{"id":"https://openalex.org/C2777042071","wikidata":"https://www.wikidata.org/wiki/Q6509304","display_name":"Leakage (economics)","level":2,"score":0.4278714954853058},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.4174310564994812},{"id":"https://openalex.org/C2994278742","wikidata":"https://www.wikidata.org/wiki/Q137056","display_name":"Corrosion prevention","level":3,"score":0.4153084456920624},{"id":"https://openalex.org/C548081761","wikidata":"https://www.wikidata.org/wiki/Q180388","display_name":"Waste management","level":1,"score":0.34364497661590576},{"id":"https://openalex.org/C112570922","wikidata":"https://www.wikidata.org/wiki/Q60528603","display_name":"Contamination","level":2,"score":0.2633382976055145},{"id":"https://openalex.org/C522964758","wikidata":"https://www.wikidata.org/wiki/Q2019586","display_name":"Environmental remediation","level":3,"score":0.23822623491287231},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.1393178403377533},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.08771437406539917},{"id":"https://openalex.org/C18903297","wikidata":"https://www.wikidata.org/wiki/Q7150","display_name":"Ecology","level":1,"score":0.0},{"id":"https://openalex.org/C139719470","wikidata":"https://www.wikidata.org/wiki/Q39680","display_name":"Macroeconomics","level":1,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C162324750","wikidata":"https://www.wikidata.org/wiki/Q8134","display_name":"Economics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1179/000705971798324224","doi":"https://doi.org/10.1179/000705971798324224","is_oa":false,"landing_page_url":"https://doi.org/10.1179/000705971798324224","pdf_url":null,"source":{"id":"https://openalex.org/S187934678","display_name":"British Corrosion Journal","issn_l":"0007-0599","issn":["0007-0599","2048-2892"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","norway-1"],"host_organization":"https://openalex.org/P4310320547","host_organization_name":"Taylor & Francis","host_organization_lineage":["https://openalex.org/P4310320547","https://openalex.org/P4310320449"],"host_organization_lineage_names":["Taylor & Francis","Informa"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"British Corrosion Journal","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":1,"referenced_works":["https://openalex.org/W1981572437"],"related_works":["https://openalex.org/W2073068570","https://openalex.org/W3021291394","https://openalex.org/W7007663908","https://openalex.org/W2023178700","https://openalex.org/W2001340910","https://openalex.org/W2018492196","https://openalex.org/W2062751188","https://openalex.org/W4241237743","https://openalex.org/W1974487899","https://openalex.org/W2372957236"],"abstract_inverted_index":{"The":[0],"corrosion":[1,29,75],"reactions":[2],"that":[3],"are":[4,20,26],"likely":[5],"to":[6,13,28,35,45,59],"occur":[7],"when":[8],"bare":[9],"steel":[10],"is":[11],"exposed":[12],"water":[14,65],"in":[15,57],"domestic":[16],"central":[17,68],"heating":[18,69],"systems":[19,70],"discussed":[21],"and":[22,34,44,64,71],"the":[23,36,72],"resultant":[24],"effects":[25],"related":[27],"of":[30,39,47,74],"radiators":[31,43],"per":[32],"se,":[33],"ancillary":[37],"occurrence":[38],"hydrogen":[40],"gas-locking":[41],"in.":[42],"blockage":[46],"pumps":[48],"by":[49],"loose":[50],"magnetite.The":[51],"suggested":[52],"remedial":[53],"measures":[54],"include":[55],"care":[56],"installation":[58],"prevent":[60],"air":[61],"ingress":[62],"into":[63],"leakage":[66],"from":[67],"use":[73],"inhibitors.":[76]},"counts_by_year":[{"year":2021,"cited_by_count":1}],"updated_date":"2026-08-15T07:11:24.734988","created_date":"2016-06-24T00:00:00"}
